Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Emerald Princess Cruise Line: Princess Cruises Inspection Date: 12/30/2025 Inspection Score: 92
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 28
Site: Buffet-Deck 15 - Starboard Forward Beverage Station
Violation: Six glasses were wet inside and not positioned in a way to air dry.
Recommendation: Store clean equipment and utensils: (1) In a self-draining position that allows air drying; (2) Covered or inverted.
Item No.: 27
Site: Galley-Deck 15- Warewash Area
Violation: There was a five-inch gap between the biodigester and the scrapping station; consequently, food debris fell between the gap and soiled the pipes and decks below.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Galley-Deck 15- Warewash Area
Violation: There was a five-inch gap between the biodigester and the scrapping station; consequently, food debris fell between the gap and soiled the pipes and decks below.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 02
Site: Medical-Acute Gastroenteritis (AGE) Log
Violation: The Excel version of the AGE log did not include a Comments/Notes column, as specified in the VSP 2025 Environmental Public Health Standards.
Recommendation: Complete all fields of the AGE surveillance log, even if entry is zero or nonapplicable. If a field is not completed, document the reason in the notes column (for example, a virtual consultation). Ensure the log data is exported in an analyzable form (such as Microsoft Excel or Microsoft Access) in the exact order noted above. Ensure any additional data fields in the surveillance log are entered only outside of the form margins when exported.
Item No.: 11
Site: Medical-AGE Log
Violation: A food employee continued to work after experiencing AGE symptoms. On 8 December, the crew member started working at 1100 and experienced symptoms at 1130. The crew member continued to work until 2200 and then reported to medical. The crew member received retraining and disciplinary action.
Recommendation: When food employees are symptomatic and meet the case definition for AGE, ensure the following actions are taken: (1) Isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) Follow-up with and receive approval by designated medical personnel before returning crew to work; (3) Document date and time of last symptom and clearance to return to work; (4) Review [when possible] any reportable AGE cases among passengers or crew reported after the food employee's illness onset for epidemiologic link/connection. Ensure the food employee's supervisor or person in charge conducts an assessment of food prepared or served by the food employee while symptomatic and take appropriate corrective actions. Document corrective actions taken as a result of the assessment.
Item No.: 06
Site: Recreational Water Facilities-Legionella Testing
Violation: The spa pool and whirlpool spas were not tested for Legionella every three months. This is a new requirement in the VSP 2025 Environmental Public Health Standards. Legionella sampling last occurred in August 2025.
Recommendation: Sample the potable water system for Legionella at least every 6 months. Ensure sample sites are representative of the potable water and RWF systems and number of samples depends on the size and complexity of the vessel. Take follow-up actions when Legionella is detected based on the type of Legionella found, the concentration (for example in CFU/ml), and the extent of colonization. Actions can include (1) Review of the water management program; (2) Root cause analysis to understand possible reasons for Legionella growth; (3) Updates to the water management program if needed. Consider retesting fixtures or devices where Legionella was detected to confirm the effectiveness of the response and to determine if remediation is needed. For additional guidance, see ASHRAE Guideline 12, Appendix C5. The Legionella sampling plan must include a selection of the following locations: (1) Potable water storage tanks; (2) Water heaters and hot water storage; (3) Hot water return lines; (4) Representative points of use in cabins, galleys, and recreational areas. Include a mix of fixture types (showers, sink faucets, tubs). Include potable water samples when temperatures are in the range favorable for Legionella growth (77°?113°F, 25°?45°C); (5) Decorative water features; (6) Misting systems; (7) Salon and pedicure devices; (8) Technical water sources with a risk of exposure via aerosolization to crew or passengers, such as deck washing. Sample all spa pools, whirlpool spas, and heated jetted tubs for Legionella at least every 3 months. If Legionella is found, conduct follow-up sampling. Collect samples at least 48 hours after the facility has been restored to normal operating conditions after remediation. Note: Ships may test for Legionella every 6 months if the following criteria are met for the 24 previous months: (1) Negative Legionella test results for the spa pools, whirlpool spas, and heated jetted tubs; (2) No legionellosis cases associated with travel on the ship (including after-cruise travel-associated cases identified by public health authorities). If Legionella is detected, take the following steps: (1) Close the RWF; (2) Add disinfectant and maintain at least 10 ppm of free chlorine for 1 hour; (3) Drain the water; (4) Scrub, clean, and rinse all RWF surfaces with fresh potable water and drain as needed; (5) Clean and service filters according to manufacturer recommendations; (6) Refill; (7) Return the RWF to at least the minimum free halogen residual; (8) Reopen; (9) Collect follow-up samples.
Item No.: 16
Site: Provisions-Meat Defrosting Room 4714
Violation: The ambient temperature in the meat defrosting room was 48°F. Using 4 different thermometers, containers of raw chicken, beef, pork, and lamb measured 44-45°F.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain TCS/PHF at 57°C (135°F) or above, except that roasts may be held at a temperature of 54°C (130°F); or 5°C (41°F) or less. Maintain shell eggs that have not been treated to destroy all viable Salmonella spp. are maintained at 7°C (45°F) or less.
Item No.: 20
Site: Provisions-Meat Defrosting Room 4714
Violation: The ambient temperature in the meat defrosting room was 48°F. Using 4 different thermometers, containers of raw chicken, beef, pork, and lamb measured 44-45°F.
Recommendation: Ensure equipment for cooling and heating food and holding cold and hot food is sufficient in number and capacity to maintain temperatures in TCS/PHF. Maintain food-contact equipment in good repair and proper adjustment: Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these standards.
Item No.: 33
Site: Provisions-Room 4733 Ice Cream Cooler
Violation: Frozen condensate collected on the bulkhead behind the condenser. No food was impacted.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 33
Site: Provisions-Room 4735 Frozen Vegetable Store
Violation: Frozen condensate collected on the bulkhead behind the condenser.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 27
Site: Buffet-Deck 15 - Starboard Forward Beverage Station
Violation: Three glasses out for self-service were soiled with food residue on the non-food contact area.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Buffet-Deck 15 - Beverage Stations
Violation: Doors and door hinges on the technical compartments were in disrepair and damaged in areas, which made them difficult to clean.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 26
Site: Buffet-Deck 15 - Starboard Mid Ship Beverage Stations
Violation: At both stations, the ice and water dispensing machines had dried food residue behind the ice chutes in the food splash area.
Recommendation: Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 27
Site: Buffet-Deck 15 - Starboard Mid Ship Beverage Stations
Violation: At both stations, the vent covers for the ice and water dispensing machines were heavily soiled with dust.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Buffet-Deck 15 - Bulkheads in Crew Working Side
Violation: Bulkheads and coving throughout the buffet area were soiled with food residue and in disrepair. This includes the damaged decorative wooden trim and the damaged decorative panels.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 39
Site: Food Service General-Pests
Violation: Pests were seen in the following food areas: 1 ant on the bulkhead behind the Garden Soup Kettle station (Deck 15 Buffet); 5 ants behind the Carvery (Deck 15 Buffet); 2 small flies in Deck 7 Club Fusion Bar; 1 small fly in Deck Main Galley Aft bar pantry.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in food areas.
Item No.: 30
Site: Buffet-Deck 15 - Crew Toilet Room
Violation: The crew toilet room near the entrance to the warewash area was out of service.
Recommendation: Keep toilet fixtures clean and in good repair.
Item No.: 29
Site: Buffet-Deck 15 - Warewash Area
Violation: The water temperature at the middle handwashing station was adjustable; however, the temperature at each setting did not get below 120°F (average temperature was 130°F).
Recommendation: Ensure handwashing sinks are equipped to provide water at a temperature of at least 29.4°C (85°F) through a mixing valve or combination faucet. For handwashing sinks with electronic sensors and other types of handwashing sinks where users cannot make temperature adjustments, ensure the temperature after the mixing valve does not exceed 49°C (120°F).
Item No.: 33
Site: Galley-Deck 15- Warewash Area
Violation: There was a five-inch gap between the biodigester and the scrapping station; consequently, food debris fell between the gap and soiled the pipes and decks below.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Buffet-Deck 15 - Starboard Barbecue
Violation: A large pool of standing water was in the corner near the technical compartment.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Buffet-Deck 15 - Starboard Barbecue
Violation: A large hole leading to an unknown area was in the corner bulkhead near the technical compartment.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 21
Site: Galley-Deck 15 - Aft Warewash
Violation: Five screws were missing from the bottom of the biodigester machine.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-Deck 16: Sabatini's
Violation: Peeling tape covered two holes in the non-food contact zone of the deli slicer.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Galley-Deck 16: Sabatini's
Violation: Peeling tape covered two holes in the non-food contact zone of the deli slicer. Both holes were soiled inside.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 26
Site: Bar-Deck 16: Adagio
Violation: Black debris was in the recirculating waterbath of the ice machine.
Recommendation: Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 34
Site: Galley-Deck 15: Soup Station
Violation: The floor drains under both soup kettles and both tilting kettles were clogged, which caused water to pool in each of the four scuppers.
Recommendation: Ensure the plumbing system in food areas is in good repair.
Item No.: 22
Site: Galley-Deck 15: Warewash
Violation: The hood-type potwash machine had been out-of-service since 4 November 2025.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 26
Site: Galley-Deck 7: Crown Grill
Violation: Six of the ten cast iron plates were soiled with old food debris and residue. The chef stated the plates were heated to cook the steaks then the steaks were served on the plates.
Recommendation: Ensure food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Galley-Deck 6 - Starboard Forward Ice Machine
Violation: Water continuously leaked from the deckhead behind the ice machine.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 21
Site: Galley-Deck 6 - Midship Coffee Station
Violation: The espresso machine was missing two covers around the coffee filters, which exposed the technical compartment to food splash. Parts in the technical compartment were soiled with food residue.
Recommendation: Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and are designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Galley-Deck 6 - Midship Coffee Station
Violation: The espresso machine was missing two covers around the coffee filters, which exposed the technical compartment to food splash. Parts in the technical compartment were soiled with food residue.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 22
Site: Galley-Deck 6 - Starboard Warewash
Violation: The flight-type warewash machine had been out-of-service since 28 October 2025.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) Warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction; (2) Water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program