Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Norwegian Jewel Cruise Line: Norwegian Cruise Lines Inspection Date: 01/22/2006 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Potable Water-
Violation: THE COMPREHENSIVE LIST OF BACKFLOW PREVENTION DEVICES DID NOT INCLUDE AIR GAPS AND DEVICES INSTALLED ON CABIN SHOWER HOSES.
Recommendation: 5.7.1.1.4 Ensure that the cross-connection control program includes a complete listing of cross-connections and the backflow prevention method/device for each, so there is a match to the plumbing system component and location.
Item No.: 08
Site: Potable Water-JACUZZI 1 & HYDROPOOL MACHINERY ROOM
Violation: THERE WAS NO BACKFLOW PREVENTION DEVICE INSTALLED ON THE SINK USED FOR THE PRESSURE WASH UNIT USED TO CLEAN THE FILTERS.
Recommendation: Install a vented, continuous pressure backflow prevention device on the sink faucet or the potable water lines to the sink.
Item No.: 10
Site: Recreational Water Facilities-CREW POOL
Violation: THERE WAS NO SHEPHERD'S HOOK AT THE POOL.
Recommendation: Ensure that an easy-access shepherd"s hook and approved floatation device is provided at a prominent location near each swimming pool.
Item No.: 20
Site: Preparation Room-NEUTRAL TROLLEYS
Violation: THE MERCURE NEUTRAL TROLLEY USED TO STORE AND TRANSPORT BAKED GOODS DID NOT HAVE COVED CORNERS AND HAD OTHER DIFFICULT TO CLEAN FEATURES.
Recommendation: Ensure that food-contact surfaces of food equipment complies with American National Standards Institute (ANSI) or other internationally accredited food-equipment sanitation standards for materials, design, and construction.
Item No.: 40
Site: Integrated Pest Management-
Violation: THERE WERE NO RECORDS OF PEST INSPECTIONS OF INCOMING SHIPMENTS OF FOOD AND SUPPLIES. THIS IS A NEW REQUIREMENT OF THE 2005 VSP OPERATIONS MANUAL.
Recommendation: 8.2.1.1.3 Ensure that incoming shipments of food and supplies are routinely inspected for evidence of insects, rodents, and other pests. Ensure that a record of these inspections is maintained onboard the vessel and available for review during inspections.
Item No.: 41
Site: Children Area-
Violation: THERE WERE NO DISPOSABLE GLOVES OR SANITARY WIPES IN THE CHILDREN'S TOILET FACILITIES.
Recommendation: Ensure that each toilet facility is provided with a supply of toilet tissue, disposable gloves, and sanitary wipes.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program