|
|
|
Item No.:
04
|
|
Site:
Potable Water-
|
|
Violation:
A TEST FOR FREE CHLORINE RESIDUAL IN THE POTABLE WATER AT THE INSIDE BAR PANTRY SINK NOTED 0.0 PPM. A SECOND TEST IN THE ENGINE SPACE PRIOR TO THE CHLORINE FILTER NOTED 0.0 PPM. PER THE CHIEF ENGINEER THIS WATER SAMPLE WAS REPRESENTATIVE OF THE WATER COMING FROM THE POTABLE WATER TANKS.
|
|
Recommendation:
Ensure that the halogenation device provides continuous halogenation of the potable water distribution system and maintains a free residual halogen between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) throughout the distribution system.
|
|
|
Item No.:
30
|
|
Site:
Pantry-INSIDE BAR
|
|
Violation:
A "WASH HANDS OFTEN" SIGN WAS NOT POSTED OVER THE HANDWASH SINK IN THE PANTRY.
|
|
Recommendation:
Ensure that a sign stating "WASH HANDS OFTEN" in a language that the food employees understand is posted over handwashing sinks.
|
|
|
Item No.:
19
|
|
Site:
Pantry-INSIDE BAR
|
|
Violation:
A STEP STOOL WAS STORED IN A CABINET WITH BOTTLES OF LIQUOR. THE PORTION OF THE STOOL THAT WAS STEPPED ON WAS RESTING AGAINST THE BOTTLES.
|
|
Recommendation:
Do not store the step stool in this cabinet.
|
|
|
Item No.:
19
|
|
Site:
Pantry-INSIDE BAR
|
|
Violation:
THE ICE MACHINE SCOOP WAS STORED ON THE TOP OF THE MACHINE. THE TOP OF THE UNIT WAS DUST COVERED.
|
|
Recommendation:
During pauses in food preparation or dispensing, ensure that food preparation and dispensing utensils are stored: (5) In a clean, protected location if the utensils, such as ice scoops, are used only with a food that is not potentially hazardous.
|
|
|
Item No.:
38
|
|
Site:
Pantry-INSIDE BAR
|
|
Violation:
A WET MOP WAS STORED ON THE DECK.
|
|
Recommendation:
After use, ensure that mops are placed in a position that allows them to air-dry without soiling walls, equipment, or supplies.
|
|
|
Item No.:
38
|
|
Site:
Food Service General-
|
|
Violation:
CLEANING MATERIALS/CHEMICAL CABINETS WERE NOT LABELED.
|
|
Recommendation:
Ensure that maintenance tools such as mops, brooms, and similar items are stored in a designated locker so they do not contaminate food, food-contact surfaces of utensils, and equipment, linens, and single-service and single-use articles.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
A COMPREHENSIVE CROSS-CONNECTION CONTROL PROGRAM HAS NOT BEEN DEVELOPED FOR THIS VESSEL. BACKFLOW PROTECTION DEVICES WERE NOT PROVIDED ON POTABLE WATER LINES SUPPLYING: CABIN TOILETS AND SHOWER HOSES, THREADED HOSE CONNECTIONS, COFFEE MACHINES, CARBONATORS, AND OTHER PLUMBING CONNECTIONS REQUIRING POTABLE WATER PROTECTION. IN FACT NO BACKFLOW PROTECTION DEVICES WERE NOTED ON THIS VESSEL.
|
|
Recommendation:
The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present:
(1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems. Ensure that the cross-connection control program includes at minimum: a complete listing of cross-connections and the backflow prevention method/device for each, so that there is a match to the plumbing system component and location, and an inspection frequency. Ensure that air-gaps are include din the listing. Ensure that a log documenting inspection and maintenance, in written or electronic form, is maintained and available for review during inspections. Ensure that backflow preventers are installed when air gaps are impractical or when water under pressure is required.
|
|
|
Item No.:
21
|
|
Site:
Bar-INSIDE BAR
|
|
Violation:
RAW WOOD AND EXPOSED PARTICLE BOARD SURFACES WERE NOTED IN THE BAR CABINETS, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Bar-INSIDE BAR
|
|
Violation:
A DIFFICULT TO CLEAN RIBBED WASTELINE WAS NOTED UNDER THE COFFEE UNIT.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
27
|
|
Site:
Bar-INSIDE BAR
|
|
Violation:
THE DIFFICULT TO CLEAN WASTE LINE UNDER THE COFFEE UNIT WAS SOILED.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
38
|
|
Site:
Bar-INSIDE BAR
|
|
Violation:
PERSONAL CARE PRODUCTS AND CLEANSERS WERE STORED WITH FOODS AND FOOD EQUIPMENT IN A CABINET UNDER THE COFFEE UNIT.
|
|
Recommendation:
Do not store personal care products in this area. Do not store cleansers with food.
|
|
|
Item No.:
28
|
|
Site:
Bar-INSIDE BAR
|
|
Violation:
A RED CUTTING BOARD WAS NOTED RESTING AGAINST THE BEER KEG IN THE KEG COOLER.
|
|
Recommendation:
Do not store clean equipment in the keg cooler.
|
|
|
Item No.:
28
|
|
Site:
Bar-INSIDE BAR
|
|
Violation:
GLASSES FORWARD OF THE BAR COUNTER WERE NOT STORED INVERTED OR COVERED.
|
|
Recommendation:
Ensure that clean equipment and utensils are stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
21
|
|
Site:
Bar-INSIDE BAR
|
|
Violation:
A FEW OF THE SEAMS IN THE BAR COUNTER WERE NOT ADEQUATELY SEALED, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
33
|
|
Site:
Bar-INSIDE BAR
|
|
Violation:
THE BAR DECK WAS CONSTRUCTED OF WOOD PLANKS THAT WERE NOT SMOOTH, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
21
|
|
Site:
Bar-INSIDE BAR
|
|
Violation:
COTTON ROPE WAS USED TO SECURE THE CABINETS DOORS. THE ROPE WAS NOT EASY TO CLEAN.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
27
|
|
Site:
Bar-INSIDE BAR
|
|
Violation:
A FEW OF THE RAW WOOD SURFACES IN THE BAR CABINETS WERE STAINED/SOILED. THE ROPE USED TO SECURE THE CABINET DOORS WERE SOILED.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
19
|
|
Site:
Food Service General-
|
|
Violation:
THE EQUIPMENT AND SINKS USED TO HOLD OR CLEAN FOOD WERE NOT INDIRECTLY CONNECTED TO THE WASTEWATER SYSTEM.
|
|
Recommendation:
7.7.3.1.1 Ensure that drain lines from all fixtures, sinks, appliances, compartments, refrigeration units, or devices that are used, designed for, or intended to be used in the preparation, processing, storage or handling of food, ice or drinks are indirectly connected to appropriate waste systems by means of an air-gap or air-break.
|
|
|
Item No.:
28
|
|
Site:
Food Service General-
|
|
Violation:
THE DISHWASH MACHINE AND PRE-WASH SINK WERE NOT INDIRECTLY CONNECTED TO THE WASTEWATER SYSTEM.
|
|
Recommendation:
Ensure that all drain lines from warewashing sinks or machines drain through an air-gap or air-break to a drain or scupper.
|
|
|
Item No.:
22
|
|
Site:
Galley-
|
|
Violation:
THE VESSEL DID NOT HAVE A 3-COMPARTMENT SINK.
|
|
Recommendation:
Ensure that a sink with at least 3 compartments is provided for manually washing, rinsing, and sanitizing equipment and utensils.
|
|
|
Item No.:
22
|
|
Site:
Galley-DISHWASH
|
|
Violation:
THE DISHWASH UNIT DID NOT HAVE A DATA PLATE.
|
|
Recommendation:
Ensure that warewashing machines are provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
|
|
|
Item No.:
19
|
|
Site:
Buffet-CREW MESS
|
|
Violation:
THE WICKER BREAD BASKET WAS NOT LINED. SERVING UTENSILS WERE NOT PROVIDED FOR THE BREAD BASKET OR BREAD BIN.
|
|
Recommendation:
Ensure that wood and wood wicker is not used as a food-contact surface. Ensure that consumer self-service operations, such as salad bars and buffets, for unpackaged ready-to-eat foods are provided with suitable utensils or effective dispensing methods that protect the food from contamination; and are monitored by food employees trained in safe operating procedures. Ensure that food-dispensing utensils are available for each container displayed at a consumer self-service unit such as a buffet or salad bar.
|
|
|
Item No.:
28
|
|
Site:
Buffet-CREW MESS
|
|
Violation:
COFFEE CARAFES WERE NOT INVERTED TO DRAIN. WATER WAS NOTED IN THE CARAFES THAT WERE STORED UPRIGHT AND COVERED.
|
|
Recommendation:
After cleaning and sanitizing, ensure that equipment and utensils are air-dried or adequately drained before contact with food. Ensure that clean equipment and utensils are stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
19
|
|
Site:
Buffet-CREW MESS
|
|
Violation:
A COFFEE MUG WAS USED TO DISPENSE GROUND COFFEE. THE HANDLE WAS IN CONTACT WITH THE COFFEE.
|
|
Recommendation:
Provide a serving utensil with a long handle.
|
|
|
Item No.:
28
|
|
Site:
Buffet-CREW MESS
|
|
Violation:
COFFEE FILTERS WERE STORED UNDER THE WASTE LINE OF THE UTILITY SINK.
|
|
Recommendation:
Do not store coffee filters in this area.
|
|
|
Item No.:
16
|
|
Site:
Buffet-CREW MESS
|
|
Violation:
AN OPENED CONTAINER OF UHT MILK WAS TESTED AT 60°F IN THE SMALL DOMESTIC-STYLE REFRIGERATION UNIT. A THERMOMETER WAS NOT PROVIDED IN THIS UNIT. A YOGURT CONTAINER WAS TESTED AT 40°F. THE MILK HAD BEEN OUT FOR BREAKFAST SERVICE AND WAS DISCARDED DURING THE INSPECTION.
|
|
Recommendation:
Except during preparation, cooking, or cooling, or when time is used as the public health control, ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
|
|
|
Item No.:
21
|
|
Site:
Food Service General-
|
|
Violation:
THERMOMETERS WERE NOT PROVIDED IN THE REFRIGERATION UNITS.
|
|
Recommendation:
Ensure that nonfood-contact equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
|
|
|
Item No.:
20
|
|
Site:
Buffet-CREW MESS
|
|
Violation:
A DOMESTIC STYLE REFRIGERATION UNIT WAS NOTED IN THIS AREA.
|
|
Recommendation:
Ensure that food-contact surfaces of food equipment complies with American National Standards Institute (ANSI) or other internationally accredited food-equipment sanitation standards for materials, design, and construction.
|
|
|
Item No.:
19
|
|
Site:
Buffet-CREW MESS
|
|
Violation:
AN OPEN CONTAINER OF SUGAR WAS NOTED. THE SUGAR WAS DISPENSED WITH A SMALL SPOON. THE HANDLE OF THE SPOON WAS IN CONTACT WITH THE SUGAR.
|
|
Recommendation:
Store the sugar container closed. During pauses in food preparation or dispensing, ensure that food preparation and dispensing utensils are stored: (2) In food that is not potentially hazardous with their handles above the top of the food within containers or equipment that can be closed, such as bins of sugar, flour, or cinnamon.
|
|
|
Item No.:
28
|
|
Site:
Buffet-CREW MESS
|
|
Violation:
ANTI-SLIP CLOTH USED TO STORE GLASSES/MUGS WAS STORED UNDER THE UTILITY SINK WASTELINE.
|
|
Recommendation:
Do not store the cloth in this area.
|
|
|
Item No.:
36
|
|
Site:
Buffet-CREW MESS
|
|
Violation:
THE LIGHT LEVEL ALONG THE COUNTER WAS INADEQUATE.
|
|
Recommendation:
Ensure that the light intensity is at least 220 Lux (20 foot candles) in bars and at dining room waiter stations during periods of cleaning.
|
|
|
Item No.:
08
|
|
Site:
Galley-
|
|
Violation:
THE WATER LINE SUPPLYING THE HOSE CONNECTION UNDER THE HANDWASH SINK WAS NOT FITTED WITH A BACKFLOW PREVENTION DEVICE.
|
|
Recommendation:
Ensure that backflow preventers are installed when air gaps are impractical or when water under pressure is required.
|
|
|
Item No.:
08
|
|
Site:
Galley-DISHWASH
|
|
Violation:
THE POTABLE WATER LINE SUPPLYING THE PRE-WASH HOSE AT THE DISHWASH UNIT WAS NOT FITTED WITH A BACKFLOW PREVENTION DEVICE. THE HOSE HEAD EXTENDED BELOW THE SPILL LINE OF THE SINK.
|
|
Recommendation:
Ensure that backflow preventers are installed when air gaps are impractical or when water under pressure is required.
|
|
|
Item No.:
28
|
|
Site:
Galley-
|
|
Violation:
THE BOTTOM SHELVES USED TO STORE CLEAN EQUIPMENT ALLOWED FOR THESE ITEMS TO BE LESS THAN 15 CM FROM THE DECK.
|
|
Recommendation:
Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 150 mm (6 inches) above the deck.
|
|
|
Item No.:
19
|
|
Site:
Galley-
|
|
Violation:
THE BOTTOM SHELVES USED TO STORE FOOD ALLOWED FOR THESE ITEMS TO BE LESS THAN 15 CM FROM THE DECK.
|
|
Recommendation:
Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
20
|
|
Site:
Galley-HOT GALLEEY
|
|
Violation:
THE BLACK BAKING PANS WERE WORN AND HAD ROUGH SURFACES, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
31
|
|
Site:
Galley-HOT GALLEY
|
|
Violation:
SILICA GEL WAS STORED IN AN ICE CREAM TUB. THE TUB STILL HAD THE ORIGINAL LABELING.
|
|
Recommendation:
Do not store chemicals in food containers.
|
|
|
Item No.:
26
|
|
Site:
Galley-HOT GALLEY
|
|
Violation:
ALL OF THE SAUTÉ AND FRY PANS IN THE DEEP FAT FRYER CABINET WERE SOILED AND STORED AS CLEAN.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch. Ensure that the food-contact surfaces of cooking equipment and pans are kept free of encrusted grease deposits and other soil accumulations.
|
|
|
Item No.:
21
|
|
Site:
Galley-HOT GALLEY
|
|
Violation:
THE FRYER CABINETS HAD SMALL ROUND HOLES, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance. Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
27
|
|
Site:
Galley-HOT GALLEY
|
|
Violation:
THE DEEP FAT FRYER CABINETS WERE SOILED WITH GREASE.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
20
|
|
Site:
Galley-HOT GALLEY
|
|
Violation:
SLOTTED FASTENERS WERE NOTED IN THE FOOD CONTACT AREA OF THE DEEP FAT FRYERS, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
21
|
|
Site:
Galley-HOT GALLEY
|
|
Violation:
A PANEL WAS MISSING UNDER THE UPPER COIL MOUNTS AT THE RIGHT DEEP FAT FRYER, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Galley-HOT GALLEY
|
|
Violation:
THE STOVE DRIP PAN HOUSING WAS DIFFICULT TO CLEAN DUE TO LIMITED ACCESS.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material. Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
28
|
|
Site:
Galley-
|
|
Violation:
SINGLE-USE TUBS AND CONTAINERS WERE RE-USED. THESE CONTAINERS WERE DAMAGED AND DIFFICULT TO CLEAN DUE TO THEIR CONSTRUCTION.
|
|
Recommendation:
Ensure that single-service and single-use articles are not reused.
|
|
|
Item No.:
28
|
|
Site:
Galley-STORES ROOMS
|
|
Violation:
CLEAN PANS WERE STORED LESS THAN 15 CM FROM THE DECK.
|
|
Recommendation:
Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 150 mm (6 inches) above the deck.
|
|
|
Item No.:
30
|
|
Site:
Galley-COLD GALLEY
|
|
Violation:
A "WASH HANDS OFTEN" SIGN WAS NOT POSTED OVER THE HANDWASH SINK.
|
|
Recommendation:
Ensure that a sign stating "WASH HANDS OFTEN" in a language that the food employees understand is posted over handwashing sinks.
|
|
|
Item No.:
28
|
|
Site:
Galley-COLD GALLEY
|
|
Violation:
A CLEAN MIXER BOWL WAS STORED ON THE DECK.
|
|
Recommendation:
Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 150 mm (6 inches) above the deck.
|
|
|
Item No.:
19
|
|
Site:
Galley-COLD GALLEY
|
|
Violation:
FLOUR AND SALT CONTAINERS WERE NOT LABELED. A CONTAINER OF SUGAR WAS NOT COVERED.
|
|
Recommendation:
Ensure that working containers holding food or food ingredients that are removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food. Ensure that procedures for second portions and refills are as follows: (1) Except for refilling a consumer's drinking cup or container without contact between the pouring utensil and the lip-contact area of the drinking cup or container, food employees may not use tableware, including single-service articles, soiled by the consumer, to provide second portions or refills. (2) Except as specified below, self-service consumers may not be allowed to use soiled tableware, including single-service articles, to obtain additional food from the display and serving equipment.
|
|
|
Item No.:
15
|
|
Site:
Galley-COLD GALLEY
|
|
Violation:
THE VESSEL WAS VACUUM PACKAGING FOODS. THESE FOODS WERE DISCARDED.
|
|
Recommendation:
Ensure that food in a hermetically sealed container is obtained from a food-processing plant that is regulated by the food regulatory agency that has jurisdiction over the plant.
|
|
|
Item No.:
26
|
|
Site:
Galley-COLD GALLEY
|
|
Violation:
SEVERAL LOAF PANS WERE SOILED AND STORED AS CLEAN.
|
|
Recommendation:
Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
21
|
|
Site:
Food Service General-
|
|
Violation:
THE BOTTOM SHELVES OF CABINETS HAD SMALL HOLES, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-
|
|
Violation:
POTENTIALLY HAZARDOUS READY-TO-EAT FOODS HELD REFRIGERATED FOR MORE THAN 24-HOURS AFTER PREPARATION OR OPENING WERE NOT DATE MARKED WITH THE 7-DAY DISCARD LABEL.
|
|
Recommendation:
Ensure that refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food shall be consumed, which is 7 calendar days or fewer from the day the food is prepared with the day of preparation counting as day 1. (2) A container of refrigerated, ready-to-eat potentially hazardous food prepared and packaged by a food processing plant and held on the vessel after opening more than 24 hours is clearly marked, at the time the original container is opened, to indicate the date by which the food shall be consumed which is, including the day the original container is opened, 7 calendar days or fewer after the original container is opened. The day of opening is counted as day 1. Ensure that refrigerated, ready-to-eat, potentially hazardous food is discarded if not consumed within 7 calendar days from the date of preparation or opening.
|
|
|
Item No.:
19
|
|
Site:
Galley-
|
|
Violation:
A COOLER WITH ICE WAS STORED ON THE DECK IN THE WALK-IN FREEZER.
|
|
Recommendation:
Do not store the cooler on the deck.
|
|
|
Item No.:
21
|
|
Site:
Galley-
|
|
Violation:
SMALL GAPS WERE NOTED BETWEEN THE SHELVING UNITS AND THE BULKHEADS IN THE WALK-IN UNITS, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that equipment that is fixed because it is not easily movable is installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment; (2) Spaced from adjoining equipment, bulkhead, and deckhead at a distance of not more than 0.8 millimeter or 1/32 inch; or (3) Sealed to adjoining equipment or bulkhead, if the equipment is exposed to spillage or seepage.
|
|
|
Item No.:
31
|
|
Site:
Galley-
|
|
Violation:
A TUB WITH MEDICATIONS WAS STORED IN THE WALK-IN REFRIGERATOR. THE TUB WAS LABELED AND HANGING ON OUTSIDE OF A SHELF. THERE WERE NO PASSENGERS ON THE VESSEL AT THE TIME OF THE INSPECTION.
|
|
Recommendation:
Ensure that medicines located in a food area for the food employees' use are labeled and located in an area such as the chef's office to prevent the contamination of food, equipment, utensils, linens, and single-service and single-use articles. Ensure that only medicines necessary for the health of the food employees are allowed in a food area.
|
|
|
Item No.:
24
|
|
Site:
Galley-
|
|
Violation:
AN APPROVED SANITIZER WITH THE APPROPRIATE TESTING STRIPS WAS NOT AVAILABLE FOR DISINFECTING FOOD CONTACT SURFACES.
|
|
Recommendation:
Ensure that the chemical sanitizer used in a sanitizing solution for a manual or mechanical operation is listed in 21 CFR 178.1010 Sanitizing Solutions. Ensure that the chemical sanitizer is used in accordance with the EPA-approved manufacturer's label use instructions at a minimum temperature of 24°C (75°F) with an exposure time of 7 seconds for a chlorine solution and 30 seconds for other chemical sanitizers. Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm). Ensure that an iodine solution used as a sanitizing solutions has a pH of 5.0 or less or a pH no higher than the level for which the manufacturer specifies the solution is effective, and a concentration between 12.5 mg/L (ppm) and 25 mg/L (ppm). Ensure that a quaternary ammonium compound solution used as a sanitizing solution has a concentration as specified in 21 CFR 178.1010 Sanitizing Solutions and as indicated by the manufacturer's use directions included in the labeling. Ensure that if another solution concentration or temperature of a chlorine, iodine, or quaternary ammonium compound is used as a sanitizing solution, the vessel demonstrates to VSP that the solution achieves sanitization and the use of the solution shall be approved. Ensure that if a chemical sanitizer other than a chlorine, iodine, or quaternary ammonium compound is used as a sanitizing solution, it is applied in accordance with the manufacturer's use directions included in the labeling. Select an appropriate sanitizer with test strips to sanitize food contact surfaces of equipment and utensils.
|
|
|
Item No.:
21
|
|
Site:
Galley-FRONT STORES
|
|
Violation:
THE STORAGE SHELVES IN THIS AREA WERE WOODEN AND DIFFICULT TO CLEAN.
|
|
Recommendation:
Ensure that nonfood-contact surfaces of equipment and utensils are designed and constructed to be durable and to retain their characteristic qualities under normal use conditions. Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
33
|
|
Site:
Food Service General-
|
|
Violation:
THE BULKHEAD WAS DIFFICULT TO CLEAN IN THE STORES AREA AND GALLEY DUE TO ATTACHED EQUIPMENT.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
30
|
|
Site:
Bar-BUITEN BAR
|
|
Violation:
A "WASH HANDS OFTEN" SIGN WAS NOT POSTED OVER THE HANDWASH SINK.
|
|
Recommendation:
Ensure that a sign stating "WASH HANDS OFTEN" in a language that the food employees understand is posted over handwashing sinks.
|
|
|
Item No.:
31
|
|
Site:
Bar-BUITEN BAR
|
|
Violation:
A CAN OF ROACH SPRAY WAS STORED WITH CLEANSERS. THIS WAS CORRECTED.
|
|
Recommendation:
Ensure that pesticides, insecticides, and rodenticides are stored in a locked area of the vessel that is not in a food area.
|
|
|
Item No.:
20
|
|
Site:
Bar-BUITEN BAR
|
|
Violation:
A DOMESTIC-STYLE REFRIGERATION UNIT WAS NOTED.
|
|
Recommendation:
Ensure that food-contact surfaces of food equipment complies with American National Standards Institute (ANSI) or other internationally accredited food-equipment sanitation standards for materials, design, and construction.
|
|
|
Item No.:
36
|
|
Site:
Bar-BUITEN BAR
|
|
Violation:
THE LIGHTING LEVEL WAS INADEQUATE.
|
|
Recommendation:
Ensure that the light intensity is at least 220 Lux (20 foot candles) in bars and at dining room waiter stations during periods of cleaning.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-
|
|
Violation:
THE VESSEL DID NOT HAVE AN INTEGRATED PEST MANAGEMENT PLAN.
|
|
Recommendation:
Ensure that each vessel develops an Integrated Pest Management Plan to address effective monitoring and control strategies for pests aboard the vessel.
|
|
|
Item No.:
41
|
|
Site:
Housekeeping-
|
|
Violation:
THE VESSEL DID NOT HAVE AN OUTBREAK PREVENTION RESPONSE PLAN.
|
|
Recommendation:
Ensure that each vessel has a written Outbreak Prevention and Response Plan (OPRP) which details the standard procedures and policies to specifically address gastrointestinal illness onboard. The plan shall include the duties and responsibilities of each department and their staff to include steps in outbreak management and control as well as the trigger for each step.
|
|
|
Item No.:
19
|
|
Site:
Buffet-
|
|
Violation:
SNEEZE GUARDS WERE NOT PROVIDED FOR THE COLD OR HOT DISPLAY STATIONS.
|
|
Recommendation:
Ensure that food on display is protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
|
|
|
Item No.:
28
|
|
Site:
Buffet-HOT BUFFET
|
|
Violation:
A VACUUM CLEANER HEAD AND BRUSH ATTACHMENTS WERE STORED WITH CLEAN SERVING UTENSILS IN A DRAWER BEHIND THE BUFFET.
|
|
Recommendation:
Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 150 mm (6 inches) above the deck.
|
|
|
Item No.:
28
|
|
Site:
Buffet-HOT BUFFET
|
|
Violation:
THE PLATES ON THE TOP OF THE BUFFET STATION WERE NOT STORED COVERED OR INVERTED.
|
|
Recommendation:
Ensure that clean equipment and utensils are stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
30
|
|
Site:
Buffet-HOT BUFFET
|
|
Violation:
A SOAP DISPENSER, SOAP, A PAPER TOWEL DISPENSER, AND PAPER TOWELS WERE NOT PROVIDED AT THE HANDWASH SINK. A "WASH HANDS OFTEN SIGN WAS NOT POSTED OVER THE HANDWASH SINK. THIS SINK WAS THE SINK TO BE USED BY THE BARTENDER. THE BAR PANTRY DOOR WAS NORMALLY KEPT CLOSED WHEN THE BAR WAS OPEN AND THERE WAS NO HANDWASH SINK BEHIND THE BAR.
|
|
Recommendation:
Ensure that a sign stating "WASH HANDS OFTEN" in a language that the food employees understand is posted over handwashing sinks. Ensure that a handwashing facility includes a sink, soap dispenser, single-use towels dispenser, and waste receptacle. Ensure that each handwashing facility has a supply of hand-cleansing soap or detergent and a supply of single-service paper towels available.
|
|
|
Item No.:
02
|
|
Site:
Medical-
|
|
Violation:
THE VESSEL WAS NOT MAINTAINING A STANDARDIZED GASTROINTESTINAL ILLNESS LOG. 72-HOUR QUESTIONNAIRES WERE NOT DISTRIBUTED TO PASSENGERS OR CREW MEMBERS WHO WERE DIAGNOSED WITH GASTROINTESTINAL ILLNESS. PER THE 1ST OFFICER PATIENT RECORDS WERE DESTROYED AFTER EACH CRUISE.
|
|
Recommendation:
Ensure that a standardized gastrointestinal illness surveillance log for each cruise is maintained daily by the master of the vessel, the medical staff, or other designated staff. Ensure that questionnaires containing all of the data elements that appear in the questionnaire found in Annex 13.2 and detailing activities and meal locations for the 72 hours before illness onset are distributed to all passengers and crew members who are gastrointestinal illness cases. Ensure that the completed questionnaires are maintained alongside the gastrointestinal illness surveillance log. Ensure that the medical log, gastrointestinal illness log and the 72 hour self-administered questionnaires are maintained on the vessel for 12 months. Ensure that the gastrointestinal illness surveillance log and the 72 hour self-administered questionnaires are available for review by the VSP during inspections and outbreak investigations and that these materials are transmitted by facsimile to the VSP for review in outbreak investigations, as requested.
|
|
|
Item No.:
01
|
|
Site:
Medical-
|
|
Violation:
THE VESSEL WAS NOT MAKING 24-HOUR REPORTS PRIOR TO ARRIVAL IN THE UNITED STATES FROM A FOREIGN PORT. DURING THE PAST CRUISE THE VESSEL ENTERED THE US FROM ST MARTIN AND ALSO FROM NASSAU.
|
|
Recommendation:
Ensure that the master, the medical staff, or other designated staff of a vessel destined for a U.S. port from a foreign port submits at least one standardized gastrointestinal illness report based on the number of reportable cases in the gastrointestinal illness log to the VSP no less than 24 hours, but not more than 36 hours before the vessel's expected arrival at the U.S. port.
|
|
|
Item No.:
11
|
|
Site:
Medical-
|
|
Violation:
A HANDWASHING AND PERSONAL HYGIENE SHEET FOR DISTRIBUTION TO PASSENGERS ILL WITH GASTROINTESTINAL ILLNESS HAS NOT BEEN DEVELOPED FOR THIS VESSEL. THERE WAS NO INDICATION THAT THERE WAS A SYSTEM TO INTERVIEW ASYMPTOMATIC CABIN MATES OF ILL CREW MEMBERS. THIS IS A NEW REQUIREMENT IN THE 2005 VSP OPERATIONS MANUAL.
|
|
Recommendation:
Ensure that medical staff conduct verbal interviews with asymptomatic cabin mates or immediate contacts to confirm their condition, advise them of the hygiene and handwashing facts, and instruct them to report immediately to medical if they develop illness symptoms. Ensure that medical staff conduct daily verbal interviews with asymptomatic crew until 48 hours after onset of the ill crew members symptoms. Ensure that symptomatic passengers meeting the definition for AGE are provided handwashing tips and personal hygiene information.
|
|
|
Item No.:
11
|
|
Site:
Medical-
|
|
Violation:
THERE WAS NO INDICATION THAT THE APPROPRIATE 48-HOUR SYMPTOM FREE ISOLATION PERIOD WAS MAINTAINED FOR A COOK WHO REPORTED WITH GASTROINTESTINAL ILLNESS SYMPTOMS ON MARCH 09, 2006. THIS IS A NEW ITEM IN THE 2005 VSP OPERATIONS MANUAL.
|
|
Recommendation:
Ensure that symptomatic food employees meeting the case definition for AGE are isolated in cabin or designated, restricted area until symptom-free for a minimum of 48 hours. Ensure that follow-up with and approval by designated medical personnel is completed before returning crew (food and non-food) to work.
|
|
|
Item No.:
02
|
|
Site:
Medical-
|
|
Violation:
THE VESSEL DID NOT HAVE SAMPLE COLLECTION CONTAINERS FOR STOOL SPECIMENS FOR VIRAL AND BACTERIAL SAMPLING. THE VESSEL DID NOT HAVE SHIPPING CONTAINERS AND LABELS FOR SHIPPING CLINICAL SPECIMENS. THIS IS A NEW REQUIREMENT IN THE 2005 VSP OPERATIONS MANUAL.
|
|
Recommendation:
Ensure that at least 10 clinical specimen collection containers for both viral and bacteriological agents (10 each), as well as the proper shipping containers and labels for same, are maintained by the medical staff.
|
|
|
Item No.:
17
|
|
Site:
Food Service General-
|
|
Violation:
THE COOLING LOG DID NOT NOTE THE TEMPERATURE OF THE FOODS WHEN COOLING BEGAN. THIS IS A NEW REQUIREMENT IN THE 2005 VSP OPERATIONS MANUAL.
|
|
Recommendation:
Ensure that logs documenting cooked, potentially hazardous food cooling temperatures and times from the starting points designated in 7.3.5.2.1 thru the control points at 2 and 6 hours are maintained onboard the vessel for a period of 30 days form the date the food was placed in the cooling process.
Ensure that logs documenting cooling of potentially hazardous foods prepared from ingredients at ambient temperatures, with the start time to the time when 5°C (41 °F) is reached are also maintained for a period of 30 days, beginning with the day of preparation.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-
|
|
Violation:
THERE WAS NO INDICATION THAT THE COLD SMOKED FISH WAS FROZEN TO THE TIME AND TEMPERATURE REQUIRED FOR PARASITE DESTRUCTION.
|
|
Recommendation:
Before service in ready-to-eat form, ensure that raw, raw-marinated, partially cooked, or marinated-partially cooked fish other than molluscan shellfish: (1) Are frozen throughout to a temperature of -20°C (-4°F) or below for 168 hours (7 days) in a freezer; or -35°C (-31°F) or below for 15 hours in a blast freezer. Before service in ready-to-eat form, ensure that raw, raw-marinated, partially cooked, or marinated-partially cooked fish other than molluscan shellfish: (1) Are frozen throughout to a temperature of -20°C (-4°F) or below for 168 hours (7 days) in a freezer; or -35°C (-31°F) or below for 15 hours in a blast freezer.
|
|
|
Item No.:
17
|
|
Site:
Food Service General-
|
|
Violation:
THERE WAS NO DOCUMENTATION NOTING THAT THE FISH WAS FROZEN TO THE TIME AND TEMPERATURE REQUIRED FOR PARASITE DESTRUCTION.
|
|
Recommendation:
Ensure that, if raw, raw-marinated, partially cooked, or marinated-partially cooked fish are served in ready-to-eat form: (1) The person in charge records the freezing temperature and time to which the fish are subjected and retains the records on the vessel for 90 calendar days beyond the time of service or sale of the fish; or (2) If the fish are frozen by a supplier, a written letter from the supplier which specifies the fish species involved and both the temperature to which the fish was frozen and the total time period at that temperature. If the supplier provides any of the same species to the vessel in a fresh state, there shall be some designation on the outer packaging for the parasite-free fish.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-
|
|
Violation:
A CONSUMER ADVISORY WAS NOT AVAILABLE ON THE VESSEL.
|
|
Recommendation:
If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, ensure that the passengers are informed by vessel newsletter articles, brochures, embarkation television broadcasts, menu advisories, placards, or other written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-
|
|
Violation:
A TIME CONTROL PLAN HAS NOT BEEN DEVELOPED FOR THIS VESSEL.
|
|
Recommendation:
If time only, rather than time in conjunction with temperature, is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure that (1) The food is marked or otherwise identified to indicate the time that is 4 hours past the point in time when the food is removed from temperature control; (2) The food is cooked and served, served if ready-to-eat, or discarded, within 4 hours from the time when the food is removed from temperature control; and (3) The food in unmarked containers or packages or marked to exceed a 4 hour limit is discarded. Ensure that written procedures to ensure compliance with these guidelines is maintained on the vessel and made available to the VSP, upon request.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-
|
|
Violation:
THE VESSEL WAS NOT TESTING THE DISTRIBUTION SYSTEM FOR THE PRESENCE OF E COLI.
|
|
Recommendation:
Ensure that a minimum of four potable water samples per month are collected and analyzed for the presence of Escherichia coli and are collected randomly from locations on the forward, aft, upper, and lower decks of the vessel. Ensure that sample sites are changed each month.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-
|
|
Violation:
THE VESSEL DID NOT HAVE THE LATEST MICROBIOLOGIC TESTING RESULTS FOR WATER THAT WAS BUNKERED. THE VESSEL BUNKERED WATER ON 12/20/05 IN MARTINIQUE.
|
|
Recommendation:
Where available, ensure that the vessel has a copy of the most recent microbiologic report from each port before bunkering potable water to verify that the water meets potable standards.
|
|
|
Item No.:
03
|
|
Site:
Potable Water-
|
|
Violation:
THERE WAS NO INDICATION (RECORDS) THAT THE WATER THAT WAS BUNKERED OR PRODUCED WAS CHLORINATED TO 2 PPM FREE CHLORINE.
|
|
Recommendation:
Ensure that potable water is continuously halogenated to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device that is controlled by a flow meter.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
THE VESSEL WAS NOT TESTING THE BUNKERED WATER FOR FREE CHLORINE HOURLY. THE VESSEL WAS NOT TESTING THE PRODUCED WATER FOR FREE CHLORINE RESIDUAL EVERY 4 HOURS.
|
|
Recommendation:
Ensure that free residual halogen monitoring is performed at least hourly during the bunkering of potable water and performed at least once every 4 hours during the onboard production of potable water.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-
|
|
Violation:
AN ANALYZER CHART RECORDER WAS NOT INSTALLED TO TEST THE FREE CHLORINE RESIDUAL IN THE DISTRIBUTION SYSTEM. THE TEST KIT USED TO TEST FOR FREE CHLORINE RESIDUAL NOTED 0.41 PPM WHILE THE WATER SAMPLE WAS CLEAR AFTER THE ADDITION OF THE REAGENT. THERE WERE NO TEST RESULTS TO INDICATE THAT THE LEVEL OF FREE CHLORINE IN THE DISTRIBUTION SYSTEM WAS MAINTAINED BETWEEN 0.2-5.0 PPM. A LOW LEVEL ALARM WAS NOT INSTALLED TO INDICATE LOW FREE CHLORINE RESIDUALS.
|
|
Recommendation:
Ensure that a halogen analyzer-chart recorder is installed at a distant point in the potable water distribution system where a significant water flow exists. In cases where dual distribution loops exist, and no pipes connect the loops, ensure that an analyzer and chart recorder is installed on each loop. Ensure that the test kit used to calibrate the halogen analyzer is graduated in increments no greater than 0.2 mg/L (ppm) in the range of free residual halogen normally maintained in the potable water system. Ensure that records from the halogen analyzer-chart recorder verify the free residual halogen between 0.2 mg/L (ppm) and 5.0 mg/L (ppm) in the water distribution system for at least 16 hours in each 24-hour period since the last inspection of the vessel. Ensure that manual readings are recorded on a chart or log, retained for at least 12 months, and are available to the VSP for review during inspections. Ensure that an audible alarm is provided in a continuously occupied watch station (i.e. engine room) to indicate low free halogen readings at the distant point analyzer. Ensure that all distribution water system halogenation devices are constructed and installed in accordance with recommended engineering practices.
|
|
|
Item No.:
06
|
|
Site:
Potable Water-
|
|
Violation:
A CHLORINE PUMP AND BACK-UP PUMP WERE NOT INSTALLED ON THE POTABLE WATER SYSTEM TO INJECT CHLORINE AS NEEDED TO THE POTABLE WATER EXITING THE TANKS.
|
|
Recommendation:
Ensure that all distribution water system halogenation devices are constructed and installed in accordance with recommended engineering practices. Ensure that at least one backup halogen pump is available with automatic switchover to maintain the free residual halogen in the event that the primary pump fails, an increase in demand occurs, or the low chlorine alarm sounds.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
SAMPLE POINTS WERE NOT INSTALLED ON EACH POTABLE WATER TANK. THE POTABLE WATER TANKS WERE NOT LABELED "POTABLE WATER".
|
|
Recommendation:
Ensure that potable water tanks are identified with a number and the words "POTABLE WATER" in letters 13 mm (0.5 inch) high. Ensure that potable water tanks have sample valves which are turned down.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
THERE WERE NO RECORDS ON THE DISINFECTION AND CLEANING OF THE POTABLE WATER TANKS.
|
|
Recommendation:
Ensure that potable water tanks are inspected, cleaned, and disinfected during dry docks and wet docks, or every 2 years, whichever is less. Ensure that documentation of any inspection, cleaning, disinfection (including concentration and contact time of disinfectant), and flushing is maintained for 12 months and is available to the VSP for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
THERE WAS NO DOCUMENTATION ON THE COATING USED INSIDE THE POTABLE WATER TANKS. THIS IS A NEW REQUIREMENT IN THE 2005 VSP OPERATIONS MANUAL.
|
|
Recommendation:
Ensure that interior coatings on potable water tanks are approved for potable water contact, and all manufacturer's recommendations for application, drying, or curing are followed. Ensure written documentaion for the coating used and recommendations followed are available for review during inspections.
|
|
|
Item No.:
41
|
|
Site:
Ventilation-
|
|
Violation:
THE CONDENSATE COLLECTION SYSTEM AND DRAIN PAN WERE NO ACCESSIBLE FOR INSPECTION. A CLEANING AND MAINTENANCE PLAN AND RECORDS WERE NOT AVAILABLE.
|
|
Recommendation:
Ensure that air handling unit condensate drain pans and collection systems are accessible for inspection, maintenance, and cleaning. Ensure that air condition condensation collection pans are self-draining. Ensure that air handling units are kept clean. Ensure that evaporative condensers are inspected at least annually and cleaned as necessary to remove scale and that sediment and cooling coils and condensate pans are cleaned as necessary to remove dirt and organic material. Ensure that vessels have a written plan to inspect, clean, and maintain the heating, ventilation, and air conditioning systems in accordance with manufactures recommendations and industry standards. Ensure that the plan is available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
SAMPLE POINTS FOR TESTING THE POTABLE WATER FOR FREE CHLORINE RESIDUAL AFTER THE INJECTION POINT ON THE BUNKER AND PRODUCTION LINES WERE NOT A LEAST 3 METERS AWAY FROM THE INJECTION POINT.
|
|
Recommendation:
Ensure that water samples for halogen testing are obtained from a sample cock located on the bunker or production water line at least 3 m (10 feet) after the halogen injection point and before the storage tank.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
A REDUCED PRESSURE BACKFLOW PROTECTION DEVICE WAS NOT INSTALLED ON THE INTERNATIONAL SHORE CONNECTION FOR THE FIRE SUPPRESSION SYSTEM.
|
|
Recommendation:
The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present:
(1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems. Install reduced pressure backflow protection devices on the international shore connections for the fire suppression system.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
THE HOSE STORAGE LOCKER WAS NOT LABELED.
|
|
Recommendation:
Ensure that potable water hose lockers are marked "POTABLE WATER HOSE AND FITTING STORAGE" in letters at least 13 mm (0.5 inch) high.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
THE POTABLE WATER HOSES WERE NOT LABELED "POTABLE WATER ONLY" AT THE CONNECTION ENDS.
|
|
Recommendation:
Ensure that potable water hoses are labeled for use with the words "potable water only" in letters at least 13mm (0.5 inch) at each connecting end.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
THE POTABLE WATER HOSES WERE NOT STORED WITH THE ENDS CAPPED OR COUPLED TOGETHER. THE BUNKER FILLING LINE WAS NOT LABELED.
|
|
Recommendation:
Ensure that each potable water filling line is painted auxiliary blue and clearly marked "POTABLE WATER FILLING" in letters at least 13 mm (0.5 inch) high, stamped on a non-corrosive label plate or the equivalent and located at or near the point of hose connection. Ensure that potable water hoses are stowed rolled tight with the ends capped, on reels, or racks or with ends coupled together in potable water hose lockers.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-
|
|
Violation:
POTABLE WATER LINES WERE NOT STRIPED BLUE.
|
|
Recommendation:
Ensure that potable water piping and fittings are painted or stripped auxiliary blue, or in accordance with ISO 14726, at 5 m (15 feet) intervals on each side of partitions, decks, and bulkheads in all spaces, except where the decor would be marred by such markings.
|
|
|
Item No.:
29
|
|
Site:
Bar-BUITEN BAR
|
|
Violation:
A HANDWASH SINK WAS NOT PROVIDED AT THE BAR.
|
|
Recommendation:
Ensure that each food preparation area, bar, warewashing area, and garbage-processing area has at least one handwashing facility located in it. Ensure that the handwashing facility is located within 8 m (25 feet) of all parts of the area and is not located in an adjacent area that requires passage through a closed door. where the user makes hand contact with the door.
|
|
|
Item No.:
04
|
|
Site:
Potable Water-
|
|
Violation:
A CHARCOAL FILTER WAS INSTALLED ON THE POTABLE WATER SYSTEM IN THE ENGINE ROOM. THIS CHLORINE FILTER IS SET TO REMOVE THE CHLORINE FROM THE POTABLE WATER EXITING THE TANKS.
|
|
Recommendation:
Remove the chlorine filter.
|
|