Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Carnival Miracle Cruise Line: Carnival Cruise Lines, Inc. Inspection Date: 08/07/2007 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 34
Site: Galley-Main Galley - Soup Station
Violation: A small potable water leak was noted in the potable water line above the handwash station.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 21
Site: Galley-Main Galley - Pastry
Violation: The pipe lagging in the technical compartment 4811.011.077 was damaged.
Recommendation: Repair damaged pipe lagging.
Item No.: 08
Site: Galley-Main Galley - Pastry
Violation: The soft serve ice cream maker was equipped with a valve at the end of the hose line. It could not be determined if there was a continous pressure backflow preventer installed on the unit or the potable water supply line.
Recommendation: Verify that a continuous pressure backflow prevention device is installed on this potable water line. Ensure that a continuous pressure-type backflow preventer is installed when a valve is located downstream from the backflow preventer.
Item No.: 33
Site: Galley-Main Galley - Center Galley
Violation: Recessed grout was noted in this area. The ship is actively pursuing corrective action.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 26
Site: Galley-Main Galley - Potwash
Violation: A previously cleaned pan was found soiled and stored as clean.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 16
Site: Galley-Main Galley - Roaster Freezer
Violation: Four pans of cooked frozen vegetables were found with an 8-day vice 7-day labels. This item was corrected during the inspection.
Recommendation: Ensure that refrigerated, ready-to-eat, potentially hazardous food: (1) Prepared on a vessel and held refrigerated for more than 24 hours is clearly marked at the time of preparation to indicate the date or day by which the food shall be consumed, which is 7 calendar days or fewer from the day the food is prepared with the day of preparation counting as day 1. (2) A container of refrigerated, ready-to-eat potentially hazardous food prepared and packaged by a food processing plant and held on the vessel after opening more than 24 hours is clearly marked, at the time the original container is opened, to indicate the date by which the food shall be consumed which is, including the day the original container is opened, 7 calendar days or fewer after the original container is opened. The day of opening is counted as day 1.
Item No.: 21
Site: Galley-Main Galley - Dishwash Area
Violation: Some of the waiter trays were damaged along the edges, making cleaning difficult.
Recommendation: Replace the damaged waiter trays.
Item No.: 33
Site: Pantry-Room Service Pantry
Violation: The bottom of some bulkhead panels were pulled from the bulkhead, leaving an opening that could harbor insects and debris.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 33
Site: Galley-Crew Galley
Violation: Recessed grout was noted between deck tiles in this area.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 27
Site: Galley-Crew Galley
Violation: The counter under the meat slicer was soiled with food debris. The area was last used the previous day.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Preparation Room-Provisions - Fish Preparation Room
Violation: A loose profile strip was noted at the entry to the walk-in refrigeration unit
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, are maintained in good repair.
Item No.: 33
Site: Bar-Pool Bar
Violation: The deck between the forward and aft section of the Pool Bar service areas were soiled with dirt and paper on both (port and starboard) sides. These areas are difficult to clean due to the deep channels.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Bar-Pool Bar
Violation: The deck coating in the rear section in the technical compartment of the undercounter refrigerator #405 was peeling, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Galley-Hot Galley
Violation: Recessed grout was noted in the hot galley area, making cleaning difficult.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Buffet-Buffet Service Line
Violation: Recessed grout was noted in the work area of the some of the buffet service lines.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 22
Site: Galley-Potwash Area
Violation: There were not enough stationary racks for all the soiled items that accumulated during the breakfast service.
Recommendation: Ensure that drainboards, utensil racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program