Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: CARNIVAL CONQUEST - CAS - 12/15/2002 .
|
|
Recommendation:
|
|
|
Item No.:
19
|
|
Site:
Other-FOOD SERVICE - GENERAL
|
|
Violation:
SEVERAL AREAS HAD BOXES SETTING DIRECTLY ON THE DECK MAKING THE AREA DIFFICULT CLEAN.
|
|
Recommendation:
Provide additional pallets to ensure all food items are stored off of the deck.
|
|
|
Item No.:
22
|
|
Site:
Other-LIDO WAREWASHER
|
|
Violation:
A DATA PLATE WAS NOT PROVIDED FOR THE HOBART WAREWASHER.
|
|
Recommendation:
7.5.2.2.3
A warewashing machine shall be provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the:
(1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
|
|
|
Item No.:
24
|
|
Site:
Other-LIDO POT WASH
|
|
Violation:
THE FOOD-CONTACT SURFACE OF THE EQUIPMENT WAS BEING IMMERSED LESS THAN THE REQUIRED 30 SECONDS.
|
|
Recommendation:
7.5.6.2.2
A chemical sanitizer shall be used in accordance with the EPA-approved manufacturer's label use instructions at a minimum temperature of 24°C (75°F) with an exposure time of 7 seconds for a chlorine solution and 30 seconds for other chemical sanitizers.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY/ FORWARD DISHWASH AREA
|
|
Violation:
SEVERAL PREVIOUSLY CLEANED PLATES WERE FOUND SOILED WITH FOOD RESIDUE AND STORED AS CLEAN.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY / POT WASH AREA
|
|
Violation:
NUMEROUS PREVIOUSLY CLEAN SHEET PANS, AND UTENSILS WERE FOUND SOILED WITH FOOD RESIDUE AS STORED AS CLEAN.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Other-MAIN GALLEY / STARBOARD CTX OVEN
|
|
Violation:
THE EXHAUST HOOD OVER THE CTX OVEN WAS SOILED WITH OLD GREASE. THIS WAS THE ONLY HOOD THAT WAS SOILED.
|
|
Recommendation:
Ensure that the exhaust hood is cleaned frequently enough to keep it free from grease accumulation.
|
|
|
Item No.:
41
|
|
Site:
Other-CHILD ACTIVITY CENTER
|
|
Violation:
A CHILD SIZE TOILET SEAT WAS NOT PROVIDED IN THE CHILD ACTIVITY CENTER. THE SEAT HAS BEEN ORDERED.
|
|
Recommendation:
10.2.1.1.1
Child-size toilet and handwashing facilities shall be provided, if toilet rooms are located in a child-activity center.
|
|