Cruise Ship: Rhapsody of the Seas Cruise Line: Royal Caribbean International Inspection Date: 12/07/2003 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 06
Site: Other-POTABLE WATER
Violation: ON 10/23 AND 9/28 THE LOWER LOOP FAR POINT ANALYZER CHART RECORDER MALFUNCTIONED AND THERE WAS NO DOCUMENTATION OF MANUAL TESTS BEING TAKEN EVERY FOUR HOURS.
Recommendation: 5.5.3.1.1 Free residual halogen shall be measured by a manual test kit at the halogen analyzer at least every 4 hours in the event of equipment failure.
Item No.: 08
Site: Other-POTABLE WATER
Violation: ON THE FOLLOWING DATES, THE HALOGEN DEMAND AND PH TEST RESULTS WERE NOT RECORDED PRIOR TO BUNKERING: 11/26, 11/10, 10/26, 10/19, 10/12, 9/21, 8/31, 8/24, 8/17, 8/10, 8/3, 7/27, 7/20, 7/13, 7/9, 7/6, 6/22, 6/15, 6/8, 6/1, 5/18, AND 5/11.
Recommendation: 5.2.1.2.1 A halogen demand test and pH shall be conducted on the shore-side water supply before starting the bunkering process to establish the correct halogen dosage.
Item No.: 09
Site: Other-POOLS
Violation: FROM 7/23 TO 8/3, THE FREE CHLORINE RESIDUAL IN THE MAIN POOL WAS MEASURED ABOVE 3.0 PPM. ACCORDING TO THE FACILITIES STAFF, AN OUTBREAK WAS OCCURRING DURING THIS TIME AND IT IS COMPANY POLICY TO INCREASE THE FREE CHLORINE RESIDUAL ABOVE 3.0 PPM.
Recommendation: 6.2.2.1.1 A free residual halogen of >1.0 and <3.0 mg/L (ppm) shall be maintained in recirculated swimming pools. Scientific studies do not indicate that increasing the free residual halogen to above 3.0 ppm in the pools during an outbreak will be effective in controlling an outbreak. A level of 1000 ppm chlorine is needed to kill the norovirus.
Item No.: 38
Site: Other-HOUSEKEEPING
Violation: FIVE VACUUM CLEANERS WERE FOUND STORED IN THE ICE STATION/DECK PANTRY ON DECK 3.
Recommendation: 7.7.7.1.1 Only articles necessary for the food service operation shall be stored in food preparation, food storage, and warewashing areas.
Item No.: 31
Site: Other-HOUSEKEEPING
Violation: AN UNLABELED SPRAY BOTTLE OF BLEACH WAS FOUND STORED IN THE CLEANING LOCKER IN THE ICE STATION/DECK PANTRY ON DECK 3.
Recommendation: 7.6.1.1.2 Working containers used for storing poisonous or toxic materials such as cleaners and sanitizers taken from bulk supplies shall be clearly and individually identified with the common name of the material.
Item No.: 08
Site: Other-BARS - SOLARIUM BAR
Violation: A CARBONATOR BACK FLOW PREVENTION DEVICE [BFP] WAS LEAKING FROM THE AIR RELIEF HOLES, INDICATING POSSIBLE FAILURE.
Recommendation: 5.7.2.2.1 Backflow prevention devices should be periodically inspected and any failed units shall be replaced.
Item No.: 21
Site: Other-BARS - POOL BAR
Violation: AN EXTENSION CORD WAS DRAPED ACROSS THE BAR COUNTER, MAKING THE COUNTER DIFFICULT TO CLEAN.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 08
Site: Other-DECK 5 - MAIN GALLEY - BEVERAGE STATION
Violation: A CARBONATOR BACKFLOW PREVENTION DEVICE [BFP] WAS LEAKING FROM THE AIR RELIEF HOLES, INDICATING POSSIBLE FAILURE.
Recommendation: 5.7.2.2.1 Backflow prevention devices should be periodically inspected and any failed units shall be replaced.
Item No.: 22
Site: Other-DECK 4 - MAIN GALLEY - DISHWASHING
Violation: TWO OF THE FINAL SANITIZING RINSE NOZZLES ON THE FLIGHT TYPE DISHWASHER WERE CLOGGED, RESULTING IN AN INADEQUATE FINAL RINSE SPRAY PATTERN ON THE LEFT SIDE OF THE CONVEYOR.
Recommendation: 7.5.4.1.1 Warewashing equipment shall be maintained in good repair and proper adjustment including: (1) Warewashing equipment shall be maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. (2) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
Item No.: 26
Site: Other-CREW GALLEY
Violation: A SOILED BUFFET PAN AND A SOILED POT WERE NOTED IN THE CLEAN STORAGE AREA.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 19
Site: Other-CREW GALLEY
Violation: THE HAMBURGER COOKING OPERATION HAD A PAN OF COOKED BURGERS ADJACENT TO A PAN OF RAW BURGERS, EXPOSING THE PAN OF COOKED PRODUCT TO POSSIBLE CROSS-CONTAMINATION.
Recommendation: 7.3.3.2.1 Food shall be protected from cross-contamination by: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food including other raw animal food such as fish for sushi or molluscan shellfish, or other raw ready-to-eat food such as vegetables, and cooked ready-to-eat food; so products do not physically touch, and so as to prevent dripping of one product into another
Item No.: 26
Site: Other-BARS - CREW BAR
Violation: A SOILED POUR SPOUT WAS NOTED ON ONE OF THE MIX DISPENSER BOTTLES.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 38
Site: Other-BARS - SHOW BAR
Violation: DECORATIVE MATERIALS, INCLUDING ARTIFICIAL FLOWER ARRANGEMENTS, WERE STORED ON CASES OF SINGLE SERVICE ITEMS.
Recommendation: 7.7.7.1.1 Only articles necessary for the food service operation shall be stored in food preparation, food storage, and warewashing areas.
Item No.: 08
Site: Other-BARS - SCHOONER BAR
Violation: A CARBONATOR BACK FLOW PREVENTION DEVICE [BFP] WAS LEAKING FROM THE AIR RELIEF HOLES, INDICATING POSSIBLE FAILURE.
Recommendation: 5.7.2.2.1 Backflow prevention devices should be periodically inspected and any failed units shall be replaced.
Item No.: 29
Site: Other-HOUSEKEEPING
Violation: SOME OF THE VACUUM CLEANERS STORED IN THE ICE STATION/DECK PANTRY ON DECK 3 WERE BLOCKING THE HANDWASH SINK.
Recommendation: 7.7.1.3.1 Handwashing facilities shall be used for no other purpose and shall be accessible at all times.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: RHAPSODY OF THE SEAS - CAS - 12/7/2003.
Recommendation: