Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: RADIANCE OF THE SEAS - CAS - [INSERT INSPECTION DATE] .
|
|
Recommendation:
|
|
|
Item No.:
03
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
DURING SOME BUNKERING PERIODS, THE INITIAL HALOGEN READINGS WERE BELOW 2.0 PPM. THE REMAINING HOURLY READINGS WERE ABOVE THE REQUIRED 2.0 PPM.
|
|
Recommendation:
5.2.1.1.1
Potable water shall be continuously halogenated to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device.
|
|
|
Item No.:
19
|
|
Site:
Other-DECK 5 PASTRY
|
|
Violation:
THE HANDLE OF THE SCOOP WAS FOUND TO BE IN DIRECT CONTACT WITH THE SUGAR.
|
|
Recommendation:
7.3.3.4.2.2
During pauses in food preparation or dispensing, food preparation and dispensing utensils shall be stored:
(2) In food that is not potentially hazardous with their handles above the top of the food within containers or equipment that can be closed, such as bins of sugar, flour, or cinnamon.
|
|
|
Item No.:
20
|
|
Site:
Other-WINDJAMMER - POTWASH
|
|
Violation:
ONE LARGE PAN WAS FOUND WITH A ROUGH FOOD PREPARATION SURFACE.
|
|
Recommendation:
Replace pan or polish down rough surfaces, if possible.
|
|
|
Item No.:
21
|
|
Site:
Other-WINDJAMMER - HOT GALLEY
|
|
Violation:
ONE HINGE COVER WAS MISSING FROM THE UNDERCOUNTER REFRIGERATOR.
|
|
Recommendation:
Replace missing hinge cover.
|
|
|
Item No.:
21
|
|
Site:
Other-WINDJAMMER - HOT GALLEY PREP AREA
|
|
Violation:
ONE ALTO-SHAAM OVEN (LOWER UNIT) WAS FOUND WITH A DAMAGED GASKET.
|
|
Recommendation:
Replace damaged gasket material.
|
|
|
Item No.:
22
|
|
Site:
Other-CREW GALLEY - WAREWASH
|
|
Violation:
THE FINAL RINSE SPRAY PATTERN OF THE WAREWASH UNIT WAS ERRATIC.
|
|
Recommendation:
Ensure warewash final rinse spray patterns provide adequate coverage of all surfaces for effective sanitization.
|
|
|
Item No.:
26
|
|
Site:
Other-WINDJAMMER - SWEET DREAMS (PORT/STBD)
|
|
Violation:
SEVERAL PREVIOUSLY CLEANED SAUCERS AND 1 BOWL WERE FOUND SOILED AND STORED AS CLEAN.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Other-WINDJAMMER - PANTRY
|
|
Violation:
SEVERAL PREVIOUSLY CLEANED SAUCERS WERE FOUND SOILED AND STORED AS CLEAN.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Other-DECK 5 PASTRY
|
|
Violation:
WATER AND OTHER DEBRIS WAS FOUND ON THE INSIDE COLLAR OF THE FLOOR MIXERS.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Other-DECK 4 BEVERAGE STATIONS
|
|
Violation:
BRASS FITTINGS WERE NOTED BETWEEN THE BACKFLOW PREVENTER AND THE CARBONATOR.
|
|
Recommendation:
7.4.1.1.5
Copper and copper alloys such as brass:
(1) May not be used in contact with a food that has a pH below 6 such as vinegar, fruit juice, or wine or for a fitting or tubing installed between a backflow prevention device and a carbonator.
|
|
|
Item No.:
26
|
|
Site:
Other-BARS GENERAL
|
|
Violation:
BRASS FITTINGS WERE NOTED BETWEEN THE BACKFLOW PREVENTER AND THE CARBONATOR.
|
|
Recommendation:
7.4.1.1.5
Copper and copper alloys such as brass:
(1) May not be used in contact with a food that has a pH below 6 such as vinegar, fruit juice, or wine or for a fitting or tubing installed between a backflow prevention device and a carbonator.
|
|
|
Item No.:
26
|
|
Site:
Other-PORTOFINO GALLEY
|
|
Violation:
SEVERAL PREVIOUSLY CLEANED COFFEE URNS AND LIDS WERE FOUND SOILED AND STORED AS CLEAN
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Other-PORTOFINO GALLEY
|
|
Violation:
THREE PREVIOUSLY CLEANED DRESSING/OLIVE OIL BOTTLES WERE FOUND SOILED WITH OIL AND STORED AS CLEAN.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
33
|
|
Site:
Other-WINDJAMMER JUICE STATION
|
|
Violation:
AN EXCESSISVE AMOUNT OF SEALANT WAS NOTED BETWEEN THE STAINLESS STEEL BULKHEAD AND MARBLE BACKSPLASH BEHIND THE HANDWASH STATION.
|
|
Recommendation:
Removes excessive sealant and apply only the amount needed to seal the gaps and seams.
|
|
|
Item No.:
33
|
|
Site:
Other-WINDJAMMER - PANTRY
|
|
Violation:
BROKEN TILES WERE NOTED ON THE DECK COVING. A WORK ORDER HAS BEEN SUBMITTED FOR THIS ITEM.
|
|
Recommendation:
Repair broken tiles.
|
|
|
Item No.:
33
|
|
Site:
Other-WINDJAMMER - PREP AREA
|
|
Violation:
A LOOSE PROFILE STRIP WAS NOTED ABOVE THE COVING ADJACENT TO THE UNDERCOUNTER REFRIGERATORS, ACROSS FROM THE POTWASH AREA.
|
|
Recommendation:
Repair the loose profile strip.
|
|
|
Item No.:
33
|
|
Site:
Other-DECK 5 VEGETABLE STATION
|
|
Violation:
EXCESSIVE SEALANT WAS NOTED TO FILL A GAP BETWEEN THE BULKHEAD AND THE SOUP KETTLE EQUIPMENT.
|
|
Recommendation:
Remove excessive sealant and apply only the amount needed to seal the gap or seam.
|
|
|
Item No.:
36
|
|
Site:
Other-WINDJAMMER SALAD STATIONS
|
|
Violation:
SOME OF THE DECKHEAD LIGHTS ABOVE THE SALAD STATIONS WERE NOT SHIELDED.
|
|
Recommendation:
7.7.5.2.1
Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
|
|
|
Item No.:
38
|
|
Site:
Other-SEAVIEW CAFÉ
|
|
Violation:
A LARGE LINCOLN PIZZA OVEN IS NOT BEING USED. THIS UNIT IS SCHEDULED FOR REMOVAL DURING THE NEXT DRYDOCK DUE TO ITS SIZE. THE OVEN IS NO LONGER NEEDED SINCE PIZZAS ARE NOT PREPARED IN THE AREA ANY LONGER.
|
|
Recommendation:
Remove pizza oven at next dry dock.
7.7.7.1.1
Only articles necessary for the food service operation shall be stored in food preparation, food storage, and warewashing areas.
|
|