Cruise Ship: Carnival Glory Cruise Line: Carnival Cruise Lines, Inc. Inspection Date: 01/08/2005 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: *
Site: Other-COMMENT
Violation: THE OVERALL RECORDKEEPING AND MANAGEMENT FOR POTABLE WATER, POOLS/SPAS, HOUSEKEEPING, PEST MANAGEMENT, CHILD ACTIVITY, GALLEYS, BARS, AND LIDO FOOD AREAS WAS EXCELLENT.
Recommendation:
Item No.: *
Site: Other-COMMENT - CORRECTIVE ACTION
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
Item No.: 10
Site: Other-POOLS - CHILDRENS POOL
Violation: THERE WAS A SINGLE DRAIN IN THE CHILDREN'S POOL. THE DRAIN COVER HAD AN ANTI-VORTEX DESIGN, BUT THERE WAS NO LETTER CONFIRMING THAT IT WAS TESTED AND MET ANTI-VORTEX CRITERIA.
Recommendation: 6.4.1.2.2 Anti-vortex drain covers shall be provided on swimming pools and whirlpool spas where only single, non-channeled drains exist.
Item No.: 20
Site: Other-PIZZERIA
Violation: SLOTTED SCREWS WERE NOTED INSIDE THE SMALL PIZZA FLASH BAKE OVEN, MAKING CLEANING DIFFICULT.
Recommendation: Replace the slot-head fasteners with low profile, non-slotted fasteners.
Item No.: 21
Site: Other-MAIN GALLEY DISHWASH
Violation: THE SERVING TRAYS WERE IN DISREPAIR AROUND THE EDGES. STAFF STATED THAT THE TRAYS ARE SCHEDULED FOR REPLACEMENT THIS WEEK.
Recommendation: 7.4.5.1.2 Nonfood-contact equipment shall be maintained in good repair and proper adjustment including: (1) Equipment shall be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 26
Site: Other-HOUSEKEEPING
Violation: HEAVY IRON RESIDUE WAS PRESENT ALONG THE UPPER WATERFALL AND TOP OF THE CUBERS INSIDE THE ICE MACHINE IN THE DECK 1 FORWARD PANTRY. ADDITIONALLY THERE WAS A SMALL AMOUNT OF MOLD NOTED IN THE LOWER WATER TRAY BELOW THE LEFT SIDE CUBER PANEL.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 26
Site: Other-HOUSEKEEPING
Violation: FOUR PREVIOUSLY CLEANED GLASSES WERE NOTED WITH A SOAP FILM INSIDE. ONE OF THE GLASSES ALSO HAD LIPSTICK ON THE LIP CONTACT AREA.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 26
Site: Other-MAIN GALLEY
Violation: THE PREVIOUSLY CLEANED PASTRY FLOOR MIXER WAS SOILED WITH A BLACK GREASE AROUND THE ATTACHMENT AREA BOLTS.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 27
Site: Other-HOUSEKEEPING
Violation: SLIGHT MOLD RESIDUE WAS NOTED ON THE FRONT EXTERIOR END OF THE ICE MAKER CUBER PANEL IN THE PANTRY DECK 1 FORWARD.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 28
Site: Other-FOOD SERVICE GENERAL
Violation: THE LUBRICANT USED IN THE FLOOR MIXERS WAS NOT A FOOD-GRADE PRODUCT, PER THE MATERIAL DATA SAFETY SHEET. THIS LUBRICANT WAS NOTED LEAKING FROM THE ATTACHMENT AREA BOLTS ON THE PASTRY AND APPETIZER PANTRY FLOOR MIXERS.
Recommendation: 7.5.7.2.1 Lubricants shall be applied to food-contact surfaces that require lubrication in a manner that does not contaminate food-contact surfaces.
Item No.: 31
Site: Other-MAIN GALLEY
Violation: THE APPETIZER PANTRY FLOOR MIXER WAS LEAKING OIL FROM THE ATTACHMENT BOLT AREA.
Recommendation: 7.6.2.3.6 Lubricants shall meet the requirements specified in 21 CFR 178.3570 Lubricants with Incidental Food-Contact, if they are used on food-contact surfaces, on bearings and gears located on or within food-contact surfaces, or on bearings and gears that are located so that lubricants may leak, drip, or be forced into food or onto food-contact surfaces.