Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Carnival Pride Cruise Line: Carnival Cruise Lines, Inc. Inspection Date: 02/09/2002 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 22
Site: Other-MAIN POT WASH
Violation: THE TEMPERATURE GAUGE FOR THE 3-COMPARTMENT SINK WAS 30° OUT OF CALIBRATION. CORRECTED DURING THE INSPECTION.
Recommendation: 7.5.2.1.1 Water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use.
Item No.: 28
Site: Other-MAIN POT WASH
Violation: CLEAN CUTTING BOARDS WERE STACKED ON TOP OF EACH OTHER.
Recommendation: RECOMMEND STORING ON EDGES FOR BETTER DRYING.
Item No.: 21
Site: Other-PASTRY
Violation: MARBLE CUTTING BOARD WAS FASTENED TO A STAINLESS STEEL PLATE THAT WASN'T EASILY CLEANABLE.
Recommendation: THE CUTTING BOARD SHALL BE LOOSELY MOUNTED FOR EASILY CLEANING.
Item No.: *
Site: Other-GENERAL COMMENTS
Violation: DURING TODAY'S INSPECTION IT WAS NOTED THAT THE POTABLE WATER SYSTEM, POOLS AND SPAS, CHILD ACTIVITY CENTER, IPM AND OVERALL FOOD AND BAR OPERATIONS WERE OUTSTANDING.
Recommendation:
Item No.: 26
Site: Other-LIDO
Violation: SEVERAL PREVIOUSLY CLEANED PLATES WERE SOILED WITH A FOOD RESIDUE.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 33
Site: Other-LIDO
Violation: THE EXHAUST HOOD ABOVE THE FRYER WAS SOILED WITH A GREASE RESIDUE.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: *
Site: Other-C.A.S.
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program