Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Carnival Sunshine Cruise Line: Carnival Cruise Lines, Inc. Inspection Date: 08/12/2002 Inspection Score: 92
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 26
Site: Other-APPETIZER AREA
Violation: SEVERAL SOILED PLATES WERE STORED AS CLEAN.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 27
Site: Other-APPETIZER AREA
Violation: THERE WAS MOLD GROWTH NOTED IN THE INSIDE OF THE COLLAR ON THE FLOOR MIXER.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Other-APPETIZER AREA
Violation: THE PLATE TROLLEY WAS SOILED WITH SOME FOOD DEBRIS.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 28
Site: Other-APPETIZER AREA
Violation: PLATES WERE NOT STORED INVERTED TO ALLOW FOR AIR DRYING.
Recommendation: 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 33
Site: Other-MAIN AND CREW GALLEY
Violation: THE SCUPPERS IN THE SOUP AND TILTING PAN AREAS WERE DIFFICULT TO CLEAN DUE TO PEELING PAINT AND CORROSION.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 21
Site: Other-PASTRY
Violation: THE OVEN HANDLES WERE DIFFICULT TO CLEAN DUE TO THE PEELING ELECTRICAL TAPE THAT WAS WRAPPED AROUND THEM.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 36
Site: Other-PASTRY
Violation: SOME OF THE OVEN LIGHTS WERE NOT WORKING.
Recommendation: Fix lights.
Item No.: 26
Site: Other-PASTRY
Violation: THE BELT ON THE ROLLER WAS DIRTY.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 27
Site: Other-MAIN GALLEY - BEVERAGE STATION
Violation: THERE WAS A SLIME MOLD BUILD UP IN THE TECHNICAL SPACE OF THE CORNELIUS ICE MACHINE.
Recommendation: Clean the interior spaces of the ice machine more frequently.
Item No.: 22
Site: Other-MAIN GALLEY - GLASSWASH
Violation: THE PRESSURE GAUGE ON THE GLASSWASH MACHINE WAS NOT WORKING PROPERLY.
Recommendation: 7.5.4.1.1 Warewashing equipment shall be maintained in good repair and proper adjustment including: (1) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
Item No.: 27
Site: Other-MAIN & CREW GALLEY
Violation: THE GASKETS ON THE REACH IN REFRIGERATORS WERE SOILED WITH A FOOD RESIDUE.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Other-PROVISIONS - FRUIT ROOM
Violation: THE BULKHEAD BY THE DOOR WAS SEVERELY DAMAGED.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: 19
Site: Other-OFFICER'S MESS
Violation: CONDENSATE WAS NOTED ON THE INSIDE OF THE MILK HOLDING IN THE WMF COFFEE MACHINE.
Recommendation: Provide a top for the stainless steel milk containers.
Item No.: 33
Site: Other-MAIN & CREW GALLEY
Violation: RECESSED GROUTING WAS NOTED UNDERNEATH A SERVICE LINE AND KITCHEN COUNTERS.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
Item No.: 33
Site: Other-LIDO-HOT GALLEY
Violation: MISSING AND RECESSED DECK TILE GROUT WAS NOTED ALONG THE FLOOR SINKS IN THIS AREA.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: 22
Site: Other-LIDO-POT WASH
Violation: THE WATER TEMPERATURE IN THE HOT WATER SANITIZING SINK WAS 177F, BUT THE MOUNTED THERMOMETER ONLY REGISTERED 166F.
Recommendation: 7.5.4.1.1 Warewashing equipment shall be maintained in good repair and proper adjustment including: (1) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
Item No.: 27
Site: Other-LIDO-CHINESE GALLEY
Violation: THE NON-FOOD CONTACT AREAS OF THE DEEP FRYER WERE SOILED WITH GREASE.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 37
Site: Other-LIDO-WAREWASHER
Violation: EXCESSIVE CONDENSATION BUILDUP WAS NOTED ABOVE THE WAREWASHER AT THE CLEAN END AREA.
Recommendation: 7.4.3.2.1 Ventilation hood systems and devices shall be sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 41
Site: Other-VENTILATION
Violation: THE EVAPORATIVE CONDENSERS HAD LARGE AMOUNTS OF MOLD AND SCALE BUILDUP. NO MAINTENANCE, INSPECTION AND CLEANING PLAN WAS AVAILABLE.
Recommendation: 9.2.1.2.1 Air handling units shall be kept clean. 9.2.1.2.3 Vessels shall have a plan to inspect and maintain heating, ventilation, and air conditioning systems in accordance with manufactures recommendations and industry standards.
Item No.: *
Site: Other-COMMENT
Violation: MANAGEMENT AND RECORD KEEPING FOR POTABLE WATER, POOLS, AND SPAS WERE VERY GOOD.
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program