|
|
|
Item No.:
26
|
|
Site:
Other-APPETIZER AREA
|
|
Violation:
SEVERAL SOILED PLATES WERE STORED AS CLEAN.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Other-APPETIZER AREA
|
|
Violation:
THERE WAS MOLD GROWTH NOTED IN THE INSIDE OF THE COLLAR ON THE FLOOR MIXER.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
27
|
|
Site:
Other-APPETIZER AREA
|
|
Violation:
THE PLATE TROLLEY WAS SOILED WITH SOME FOOD DEBRIS.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
28
|
|
Site:
Other-APPETIZER AREA
|
|
Violation:
PLATES WERE NOT STORED INVERTED TO ALLOW FOR AIR DRYING.
|
|
Recommendation:
7.5.7.3.2
Clean equipment and utensils shall be stored:
(1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
33
|
|
Site:
Other-MAIN AND CREW GALLEY
|
|
Violation:
THE SCUPPERS IN THE SOUP AND TILTING PAN AREAS WERE DIFFICULT TO CLEAN DUE TO PEELING PAINT AND CORROSION.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
21
|
|
Site:
Other-PASTRY
|
|
Violation:
THE OVEN HANDLES WERE DIFFICULT TO CLEAN DUE TO THE PEELING ELECTRICAL TAPE THAT WAS WRAPPED AROUND THEM.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
36
|
|
Site:
Other-PASTRY
|
|
Violation:
SOME OF THE OVEN LIGHTS WERE NOT WORKING.
|
|
Recommendation:
Fix lights.
|
|
|
Item No.:
26
|
|
Site:
Other-PASTRY
|
|
Violation:
THE BELT ON THE ROLLER WAS DIRTY.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Other-MAIN GALLEY - BEVERAGE STATION
|
|
Violation:
THERE WAS A SLIME MOLD BUILD UP IN THE TECHNICAL SPACE OF THE CORNELIUS ICE MACHINE.
|
|
Recommendation:
Clean the interior spaces of the ice machine more frequently.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY - GLASSWASH
|
|
Violation:
THE PRESSURE GAUGE ON THE GLASSWASH MACHINE WAS NOT WORKING PROPERLY.
|
|
Recommendation:
7.5.4.1.1
Warewashing equipment shall be maintained in good repair and proper adjustment including:
(1) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
|
|
|
Item No.:
27
|
|
Site:
Other-MAIN & CREW GALLEY
|
|
Violation:
THE GASKETS ON THE REACH IN REFRIGERATORS WERE SOILED WITH A FOOD RESIDUE.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Other-PROVISIONS - FRUIT ROOM
|
|
Violation:
THE BULKHEAD BY THE DOOR WAS SEVERELY DAMAGED.
|
|
Recommendation:
7.7.4.2.3
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
|
|
|
Item No.:
19
|
|
Site:
Other-OFFICER'S MESS
|
|
Violation:
CONDENSATE WAS NOTED ON THE INSIDE OF THE MILK HOLDING IN THE WMF COFFEE MACHINE.
|
|
Recommendation:
Provide a top for the stainless steel milk containers.
|
|
|
Item No.:
33
|
|
Site:
Other-MAIN & CREW GALLEY
|
|
Violation:
RECESSED GROUTING WAS NOTED UNDERNEATH A SERVICE LINE AND KITCHEN COUNTERS.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
|
|
Recommendation:
|
|
|
Item No.:
33
|
|
Site:
Other-LIDO-HOT GALLEY
|
|
Violation:
MISSING AND RECESSED DECK TILE GROUT WAS NOTED ALONG THE FLOOR SINKS IN THIS AREA.
|
|
Recommendation:
7.7.4.2.3
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
|
|
|
Item No.:
22
|
|
Site:
Other-LIDO-POT WASH
|
|
Violation:
THE WATER TEMPERATURE IN THE HOT WATER SANITIZING SINK WAS 177F, BUT THE MOUNTED THERMOMETER ONLY REGISTERED 166F.
|
|
Recommendation:
7.5.4.1.1
Warewashing equipment shall be maintained in good repair and proper adjustment including:
(1) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
|
|
|
Item No.:
27
|
|
Site:
Other-LIDO-CHINESE GALLEY
|
|
Violation:
THE NON-FOOD CONTACT AREAS OF THE DEEP FRYER WERE SOILED WITH GREASE.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
37
|
|
Site:
Other-LIDO-WAREWASHER
|
|
Violation:
EXCESSIVE CONDENSATION BUILDUP WAS NOTED ABOVE THE WAREWASHER AT THE CLEAN END AREA.
|
|
Recommendation:
7.4.3.2.1
Ventilation hood systems and devices shall be sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
41
|
|
Site:
Other-VENTILATION
|
|
Violation:
THE EVAPORATIVE CONDENSERS HAD LARGE AMOUNTS OF MOLD AND SCALE BUILDUP. NO MAINTENANCE, INSPECTION AND CLEANING PLAN WAS AVAILABLE.
|
|
Recommendation:
9.2.1.2.1
Air handling units shall be kept clean.
9.2.1.2.3
Vessels shall have a plan to inspect and maintain heating, ventilation, and air conditioning systems in accordance with manufactures recommendations and industry standards.
|
|
|
Item No.:
*
|
|
Site:
Other-COMMENT
|
|
Violation:
MANAGEMENT AND RECORD KEEPING FOR POTABLE WATER, POOLS, AND SPAS WERE VERY GOOD.
|
|
Recommendation:
|
|