Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Carnival Glory Cruise Line: Carnival Cruise Lines, Inc. Inspection Date: 08/27/2005 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 27
Site: Galley-LIDO HOT GALLEY
Violation: THE TOP OF THE FOUR TIER OVEN WAS SOILED WITH DUST AND OTHER DEBRIS.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Galley-LIDO HOT GALLEY
Violation: OPEN SEAMS WERE NOTED ALONG THE JUNCTURE OF THE TILTING PAN AND THE BULKHEAD. OPEN SEAMS WERE NOTED ALONG THE JUNCTURE OF THE SOUP KETTLE ASSEMBLY AND THE BULKHEAD.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 20
Site: Galley-AFT LIDO PANTRY
Violation: THREE CUTTING BOARDS WERE NOTED TO BE PITTED AND SCORED, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that surfaces such as cutting blocks and boards that are subject to scratching and scoring are resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
Item No.: 21
Site: Buffet-AFT AND FORWARD BUFFET LINES
Violation: PEELING LABELS WERE NOTED ON THE HOT HOLD UNITS AT THE AFT AND FORWARD LINES, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Galley-PORTSIDE HOT GALLEY
Violation: THE GASKET ON THE MOBILE HOT HOLD UNIT WAS TORN, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that nonfood-contact equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 08
Site: Potable Water-STAIRWAY OUTSIDE THE CAPTAIN'S PANTRY
Violation: THE POTABLE WATER LINES SUPPLYING THE GLASSWASH MACHINE WERE NOT STRIPED BLUE.
Recommendation: Ensure that potable water piping is painted light blue or striped with 15 cm (6 inches) light blue bands or a light blue stripe at fittings on each side of partitions, decks, and bulkheads and at intervals not to exceed 5 m (15 feet) in all spaces, except where the decor would be marred by such markings.
Item No.: 26
Site: Galley-MAIN GALLEY - WINE CELLAR
Violation: ONE PREVIOUSLY CLEANED BAR GLASS WAS FOUND SOILED AND STORED IN THE CLEAN STORAGE RACK.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 27
Site: Galley-MAIN GALLEY - WINE CELLAR
Violation: THE EXTERIOR OF THE ICE MACHINE ICE CUBER COVER WAS SOILED.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 20
Site: Galley-MAIN GALLEY - WINE CELLAR
Violation: SLOTTED FASTENERS WERE FOUND BENEATH THE ICE CUBER, MAKING THE AREA DIFFICULT TO CLEAN.
Recommendation: Remove the slotted fasteners and replace them with smooth low profile, non-corroding fasteners.
Item No.: 33
Site: Galley-MAIN GALLEY - LINEN LOCKER
Violation: A LOOSE PROFILE STRIP NOTED ADJACENT TO THE DOOR.
Recommendation: Repair the loose profile strip noted adjacent to the door.
Item No.: 33
Site: Galley-MAIN GALLEY - SALAD APPETIZER
Violation: A LOOSE PROFILE STRIP WAS FOUND ABOVE THE DOOR.
Recommendation: Repair the loose profile strip above the door.
Item No.: 21
Site: Galley-MAIN GALLEY - SALAD APPETIZER - COLD ROOM #31
Violation: A HINGE COVER WAS MISSING ON THE AFT REACH-IN REFRIGERATOR, MAKING CLEANING DIFFICULT.
Recommendation: Replace the missing hinge cover.
Item No.: 27
Site: Galley-MAIN GALLEY -CENTER GALLEY
Violation: A PREVIOUSLY CLEANED TILTING PAN HANDLE WAS FOUND SOILED WITH FOOD DEBRIS.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 26
Site: Galley-MAIN GALLEY - CENTER GALLEY
Violation: THE COMBI-OVEN WAS HEAVILY SOILED WITH GREASE AND FOOD DEBRIS. THERE WAS AN ODOR OF OLD FOOD AND GREASE DETECTED WHEN THE DOOR WAS OPENED. THE COMBI-OVEN WAS POSTED OUT OF ORDER FOR THE PAST TWO DAYS.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Galley-MAIN GALLEY - CENTER GALLEY
Violation: LOOSE SEALANT WAS NOTED AT THE OF THE BULKHEAD BEHIND THE STEAM KETTLES.
Recommendation: Remove the loose sealant and replace with new sealant.
Item No.: 26
Site: Galley-MAIN GALLEY -GOLDEN DISHWASH AREA
Violation: SEVERAL PREVIOUSLY CLEANED RAMEKIN BOWLS (SEVERAL IN 4 RACKS) WERE FOUND SOILED AND STORED ON THE CLEAN STORAGE RACK. THESE ITEMS WERE CLEANED THE PREVIOUS EVENING.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 41
Site: Housekeeping-PUBLIC RESTROOMS - GENERAL
Violation: THERE WERE NO PAPER TOWELS OR OTHER MEANS OF EXITING THE PUBLIC RESTROOM WITHOUT RECONTAMINATING THE HANDS. IN THE MEN'S RESTROOM ON DECK 5, THERE WAS ONLY AN AIR DRYER FOR DRYING THE HANDS. THIS IS A NEW REQUIREMENT UNDER THE VSP OPERATIONS MANUAL - 2005.
Recommendation: Ensure passengers have a way to exit the public restrooms without recontaminating their hands.
Item No.: 26
Site: Provisions-BUTCHER SHOP
Violation: A BAIN MARIE PAN WAS FOUND SOILED ALONG THE EDGE WITH A SMALL AMOUNT OF FOOD DEBRIS.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Provisions-DRY STORAGE
Violation: BARE AREAS WERE OBSERVED IN THE DECK, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 27
Site: Bar-SPORTS BAR PANTRY
Violation: THE EXTERIOR END OF THE ICE MACHINE CUBER COVER WAS SOILED.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 02
Site: Medical-CLINICAL SPECIMEN SHIPPING CONTAINERS
Violation: THE SHIP DOES NOT HAVE THE PROPER SHIPPING CONTAINERS FOR TRANSPORTING DIAGNOSTIC SPECIMENS TO LABORATORIES AS REQUIRED BY DOT AND IATA SHIPPING REGULATIONS. THIS A NEW REQUIREMENT UNDER THE VSP OPERATIONS MANUAL - 2005.
Recommendation: Ensure the ship has the proper shipping containers for transporting diagnostic samples to the laboratory.
Item No.: 02
Site: Medical-DOCUMENTATION
Violation: THE SHIP DOES NOT HAVE A PROCEDURE FOR THE MAINTENANCE OF DOCUMENTATION OF CREW MEMBERS RETURNING TO THE VESSEL WITH SYMPTOMS OF GASTROINTESTINAL ILLNESS. THIS IS A NEW REQUIREMENT UNDER THE VSP OPERATIONS MANUAL - 2005.
Recommendation: Ensure the ship has the proper procedures for managing crew members who return to the vessel ill.