Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Grandeur of the Seas Cruise Line: Royal Caribbean International Inspection Date: 12/19/2014 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: *
Site: Recreational Water Facilities-Solarium Starboard Whirlpool #900
Violation: The whirlpool spa was netted, but filled with water and ready to open. There was black sediment debris noted on both the floor of the whirlpool spa and on the seat surface. Staff were brought in to vacuum and clean away this debris.
Recommendation:
Item No.: 01
Site: Medical-Gastrointestinal (GI) Illness Reporting
Violation: On voyage 14018, from 21 to 29 November, the ship did not make the required 24 hour prior to arrival notification of gastrointestinal illness cases on board. There was a weather related change to the ship's itinerary on this voyage which forced the ship to skip the port call in Key West, Florida, but the automated GI reporting system on the ship made that prior to arrival report on 24 November. Since there was no Key West port calll on the following day, the next U.S. port following a foreign port was the return to Baltimore on 29 November.
Recommendation: Ensure the master, medical staff, or other designated staff of a vessel destined for a U.S. port from a foreign port submits at least one standardized AGE report based on the number of reportable cases in the AGE log to VSP no less than 24 hours?but not more than 36 hours?before the vessel?s expected arrival at the U.S. port.
Item No.: 05
Site: Potable Water-Distribution System - Upper Loop
Violation: There were several manual comparison tests made on the upper loop far point distribution system to verify the accuracy of the analyzer device installed at the bridge. Both the ship's manual test kit and the inspector's kit were used. Initially the inspector measured values of 1.31 and 1.27 ppm free chlorine residual compared to analyzer values of 1.9 ppm, but the ship's kit displayed values at 1.9 ppm. After resolving some technical errors with the testing method performed by the ship's staff the re-testing at this location had both the inspector and ship's test kits producing similar results, which indicated differences of 0.45 to 0.48, from the analyzer device when the accuracy errors in both manual test kits were included in the evaluation. The analyzer was recalibrated during the inspection to reflect the manual values. The
Recommendation: Ensure the free residual halogen measured by the halogen analyzer is within 0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
Item No.: 08
Site: Potable Water-Cross-Connection Control Plan
Violation: Within the comprehensive listing of backflow preventers throughout the public areas of the ship there were descriptions of the cabin flexible shower hose preventers as model N9, but there were no N9 backflow preventers installed for shower connections in any of the cabins.
Recommendation: Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (1) RWFs; (2) decorative water features/fountains; (3) cabin shower hoses, toilets, whirlpool tubs, and similar facilities; (4) photographic laboratory developing machines and utility sinks; (5) beauty and barber shop spray-rinse hoses; (6) spa steam generators where essential oils can be added; (7) hose-bib connections; (8) garbage grinders and food waste systems; (9) automatic galley hood washing systems; (10) food service equipment; (11) mechanical warewashing machines; (12) detergent dispensers; (13) hospital and laundry equipment; (14) air conditioning expansion tanks; (15) boiler feed water tanks; (16) fire system; (17) public toilets, urinals, and shower hoses; (18) potable water, bilge, and pumps that require priming; (19) freshwater or saltwater ballast systems; (20) international fire and fire sprinkler water connections (install a reduced pressure assembly); (21) the potable water supply to automatic window washing systems that can be used with chemicals or chemical mix tanks; (22) water softeners for nonpotable fresh water; (23) water softener and mineralizer drain lines, including backwash drain lines (install an air gap or a reduced pressure assembly); (24) high saline discharge line from evaporators (install an air gap or a reduced pressure assembly); (25) chemical tanks; (26) other connections between the potable water system and a nonpotable water system, such as the gray water system, laundry system, or technical water system (install an air gap or a reduced pressure assembly); (27) black water or combined gray water/black water systems (install an air gap); (28) any other connection to the potable water system where contamination or backflow can occur.
Item No.: 08
Site: Potable Water-Cross-Connection Control
Violation: A number of cabins inspected on deck 4, such as those near 4526, had a small plumbing fitting installed at the flexible shower hose connection to the tap that was not a backflow prevention device or was an unapproved type, as there were no clear vents for leaking installed on the preventer. On deck 8 there was no backflow preventer installed on the shower flexible hose.
Recommendation: Provide backflow prevention devices on all fixtures using potable water and that have submerged inlets. Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or mechanical backflow prevention devices: (3) cabin shower hoses, toilets, whirlpool tubs, and similar facilities.
Item No.: 08
Site: Galley-Deck 9 - Windjammer - Hot Galley
Violation: The water supply line to the combination steamer oven had a dual check valve without an atmospheric vent installed as the backflow preventer. This oven has an automatic oven cleaning system with detergents installed on the water line downstream from this valve.
Recommendation: Provide a comprehensive cross-connection control program. Protect the following connections to the potable water system against backflow with air gaps or appropriate mechanical backflow prevention devices: (9) automatic galley washing systems; (10) food service equipment; and (12) detergent dispensers.
Item No.: 08
Site: Galley-Deck 11 - Izumi - Hot Galley
Violation: The backflow preventer for the counter-top mounted combination steamer oven was leaking from the air relief holes indicating a possible failure. Ship staff changed the backflow preventer while the inspection team was in the area.
Recommendation: Maintain backflow prevention devices in good repair.
Item No.: 16
Site: Dining Room-Deck 11 - Izumi - Restaurant
Violation: The menu had a proper consumer advisory statement but did not show an asterisk beside the statement to show linkage to all of the menu items that had the required asterisk to indicate a food that could be ordered raw or undercooked.
Recommendation:
Item No.: 20
Site: Galley-Deck 9 - Windjammer - Potwashing
Violation: Plastic-coated serving bowls in clean utensil storage had worn spots and areas where the coating was not bonded in the inner food-contact surfaces of the bowls making them difficult to clean.
Recommendation: Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
Item No.: 20
Site: Galley-Deck 4 - Beverage Station
Violation: The bulk dispenser tubing extended over 3 inches from the dispenser and was not cut diagonally.
Recommendation:
Item No.: 21
Site: Galley-Deck 9 - Windjammer - Potwashing
Violation: Plastic-coated serving bowls in clean utensil storage had worn spots in the outer non-food contact surfaces of the bowls making them difficult to clean.
Recommendation: Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 22
Site: Buffet-Deck 9 - Windjammer - Hot Buffet and Center Buffet
Violation: The sanitizer solution in the manual sanitizer solution was heavily coated with oil and food debris in two buckets.
Recommendation: Ensure the sanitize solutions are maintained clean.
Item No.: 22
Site: Galley-Deck 5 - Buffet Station
Violation: The sanitizer solution in the manual sanitizer solution was heavily coated with oil and food debris.
Recommendation:
Item No.: 28
Site: Bar-Deck 6 - Latitudes Bar
Violation: Dust and a hair were noted on a plastic tray on the service counter where disposable ice cream cups were stored. The bottom layer of cups was discarded and the tray was washed while the inspection team was in the area.
Recommendation:
Item No.: 33
Site: Provisions-Deck 1 - Frozen Fish Storage
Violation: A small leak was observed from the deckhead seam over the access walkway to the right of the door. Small icicles were forming along the seam and ice patches were noted on the deck in the walking area. No food in storage was impacted.
Recommendation:
Item No.: 33
Site: Galley-Deck 11 - Chops - Show Galley
Violation: The channels on the left and right side of the fire shutter pass through window to the dining room were heavily soiled with grease, dust and food soil.
Recommendation:
Item No.: 36
Site: Dining Room-Deck 5 - Waiter Station
Violation: The port and starboard forward waiter stations did not have 220 lux. These areas are on the ship's list of lighting improvements needed for food areas. Most of the other areas noted on the previous inspection report have already been corrected.
Recommendation:
Item No.: 38
Site: Galley-Deck 2 - Cleaning Area
Violation: A wet mop was found stored in the wringer of a mop bucket.
Recommendation:
Item No.: 44
Site: Potable Water-Manual Testing
Violation: The engineering staff who conducted the manual comparison tests for the potable water distribution system was observed repeatedly inserting the filled sample bottle into the test kit analyzer cell with significant excess water all over the exterior surface with no attempt to dry it. When the kit was examined there was an accumulation of water inside the well where the sample bottle inserts. Lastly, the staff member did not allow the sample to rest prior to pressing the read (analysis) button on the test kit after vigorous stirring. When changes were made to the methods the decrease in the chlorine residual values was significant (0.6-0.7 ppm) and the results were within 0.2 ppm free chlorine residual of the inspector's manual tests.
Recommendation: Ensure the staff making manual tests are trained and familiar with the water test kit instructions and that they follow those instructions strictly.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program