|
|
|
Item No.:
07
|
|
Site:
Potable Water-Pipe Disinfection
|
|
Violation:
On 7 May, potable water pipes were added due to the rerouting of the potable water pipes from a construction project. The sanitation records indicated the pipes were disinfected at a concentration of 200 ppm for one hour. The protocol, last revised 14 May, stated pipes were to be disinfected at 200 ppm for one hour.
|
|
Recommendation:
Disinfect after potential contamination by increasing the free residual halogen to at least 50 mg/L (ppm) throughout the affected area and maintain this concentration for 4 hours or by way of another procedure submitted to and accepted by VSP.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Pipe Disinfection
|
|
Violation:
Three 10 January pipe disinfection records did not have a free halogen residual level recorded before the pipes were placed back into service.
|
|
Recommendation:
Flush the disinfected parts of the system with potable water or otherwise dechlorinate until the free residual halogen is less than or equal to 5.00 mg/L (ppm). Document the free halogen test result.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Cross Connection Control Log
|
|
Violation:
The six air gaps for the whirlpool compensation tanks were not annually inspected and documented on the cross connection control log.
|
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Medical - Dialysis
|
|
Violation:
The reduced pressure (RP) backflow preventer was not tested and documented on the backflow preventer log. This RP was installed 15 May 2015.
|
|
Recommendation:
Inspect and test backflow prevention devices requiring testing with a test kit after installation and at least annually. Maintain the test results showing the pressure differences on both sides of the valves for each device.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Tank Maintenance Records
|
|
Violation:
The 14 March record for Tank 7S did not indicate the concentration of the disinfection. All other records included disinfection concentration and time.
|
|
Recommendation:
Maintain documentation of all inspections, maintenance, cleaning, and disinfection for 12 months and ensure it is available for review during inspections. Ensure records include a method of disinfection, concentration and contact time of the disinfectant, and a halogen value of less than or equal to 5 ppm before the tank is put back into service.
|
|
|
Item No.:
08
|
|
Site:
Recreational Water Facilities-Machinery Room - Whirlpool 700
|
|
Violation:
The air gap for the compensation tank had a plastic bag around it, and had been modified. This was corrected.
|
|
Recommendation:
Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch).
|
|
|
Item No.:
16
|
|
Site:
Galley-Park Cafe' Galley
|
|
Violation:
A 55 gallon container of cut lettuce was on a wheeled base in the center galley during lunch service on time only as a public health control. A four hour discard label was affixed to the container, but there was no mention of this among the units or areas for time control in the time control plan.
|
|
Recommendation:
Ensure the large containers are listed in the time control plan with the other holding units where time only as a public health control takes place. Maintain a written time control plan(s) that ensures compliance with these guidelines on the vessel and make it available for review during inspections. Post a time control plan at each outlet where time control is used. Ensure plan(s): (2) List refrigeration and hot holding units (compartments and cabinets) on time control (the physical units must also be labeled as such).
|
|
|
Item No.:
16
|
|
Site:
Buffet-Windjammer Coffee Station
|
|
Violation:
Several individually wrapped creamers in a loose container at the coffee station counter, which staff stated was on time control. No 4 hour discard labels was affixed to the container, and based on the labels on the creamers it was not clear if they were shelf stable.
|
|
Recommendation:
Verify with the manufacturer if the creamers require refrigeration for food safety. If they do require refrigeration for public health reasons, the creamer container should be labeled with the four hour discard time. If time only?rather than time in conjunction with temperature?is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure the food (3) Is marked or otherwise identified to indicate the time 4 hours past the point in time when the food is removed from temperature control (if the time between service set-up and closing is greater than 4 hours.
|
|
|
Item No.:
19
|
|
Site:
Pantry-Deck 4
|
|
Violation:
A bundle of wet paper towels were stored beneath the left side of the ice water bath. This was removed.
|
|
Recommendation:
Protect food from contamination by storing the food: (3) Where it is not exposed to splash, dust, or other contamination.
|
|
|
Item No.:
20
|
|
Site:
Pantry-Pool Bar Pantry
|
|
Violation:
Several slot-head screws were fastened into the underside of the tonic dispensing nozzle, which is considered a splash zone, on the soda tower in the pantry.
|
|
Recommendation:
Contact the soda tower manufacturer to repair this dispenser so the underside panel is without slotted fasteners, such as the other dispensing heads were on the same soda tower. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
20
|
|
Site:
Galley-Deck 4 Main Galley - Beverage Station
|
|
Violation:
The counter-mounted soda tower had several slot-head screws fastened into the underside of the dispensing head in position 6 of 8, which is a splash zone, and made cleaning difficult.
|
|
Recommendation:
Contact the soda tower manufacturer to repair this dispenser so the underside panel is without slotted fasteners, such as the other dispensing heads were on the same soda tower. Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
|
Item No.:
21
|
|
Site:
Buffet-Windjammer Coffee Station - Port
|
|
Violation:
A gap was present, surrounding the water supply tube, which penetrated the rear stainless steel panel inside the undercounter technical compartment at the aft coffee machine in the port side coffee station.
|
|
Recommendation:
Profile the gap at the water line penetration or install a grommet. Do not close the gap with sealant. Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Galley-Deck 5 Main Galley - Bakery
|
|
Violation:
The stainless steel dry good trolleys were built with galvanized metal wheel castors, which were heavily corroded and very difficult to clean.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
22
|
|
Site:
Galley-Windjammer Galley - Dishwash
|
|
Violation:
During active use of the conveyor dishwashing machine the mounted final, hot water-sanitizing rinse gauge displayed a temperature of only 170 °F. No issues were noted in either the spray nozzles or other condition, and the dish level final rinse temperature was 185 °F, indicating that the gauge was in disrepair or out of calibration.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Food Service General-Park Cafe' Galley and Deck 4 Main Galley
|
|
Violation:
The pot wash machine was posted out of order in the Park Cafe Galley, and the flight-type conveyor dishwash machine was out of order in the deck 4 main galley. Both machines were found in disrepair this morning according to staff.
|
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
|
|
|
Item No.:
33
|
|
Site:
Galley-Deck 5 Main Galley - Room Service Pantry
|
|
Violation:
Above the microwave oven a loose deckhead profile strip was observed, which created a difficult-to-clean gap where the panels came together. A loose connection was observed, where the bulkhead attached electrical conduit above the microwave was located. Staff re-connected the conduit sections during the inspection.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Bar-Pool Bar
|
|
Violation:
The deckhead was poorly constructed, with numerous pop rivets throughout the panels. A number of those were popped out and what remained was a gap, where the exterior metal was separated from the deckhead and that gap was difficult to clean. Patched repairs along the separated panels had come loose, and made cleaning more difficult. Lastly, large open voids were observed at the juncture of the back bar bulkhead and deckhead going across the length of the bulkhead.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
39
|
|
Site:
Buffet-Windjammer Coffee Station - Port
|
|
Violation:
A live fruit fly was observed around the aft coffee machine on the port side coffee station.
|
|
Recommendation:
Effectively control the presence of insects to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|