Cruise Ship: Radiance of the Seas Cruise Line: Royal Caribbean International Inspection Date: 09/11/2013 Inspection Score: 95
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 33
Site: Dining Room-Deck 4 Main Restaurant
Violation: There was heavy dust debris stuck along and between the deckhead panels directly over the clean counters at waiter stations 1, 3, 8, and 9 in the deck 4 main restaurant dining room.
Recommendation: Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 39
Site: Galley-Deck 4 Main Pot Wash
Violation: One filth fly was noted flying in the area of the soiled landing table.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 33
Site: Galley-Deck 4 Main Pot Wash
Violation: Cracked or broken deck tiles were noted in the pot wash area.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 28
Site: Galley-Crew Galley - Center
Violation: There was a water leak coming from the lower edge of the canopy hood (above the portable eyewash station) onto the top of a trolley of food.
Recommendation: Store cleaned equipment and utensils, laundered linens, and single-service and single-use articles: (1) in a clean, dry location; (2) in a location where they are not exposed to splash, dust, or other contamination; (3) at least 150 millimeters (6 inches) above the deck.
Item No.: 33
Site: Buffet-Crew Mess - Portable buffet section
Violation: There was poor or absent coving along the deck and bulkhead juncture behind the aft portable buffet station.
Recommendation: Cove all bulkhead/deck, equipment/deck, cabinet/deck, and deck sink coaming/deck junctures (including galleys, pantries, buffets, bars, waiter stations, dining room work counters, provisions, food storage rooms, equipment/utensil storage rooms, and toilet rooms intended for use by galley personnel).
Item No.: *
Site: Buffet-Crew and Officers Mess
Violation: The bulk milk in the locked dispensers in both the crew and officers mess beverage stations were set inside the units without any support. As the refrigerated dispenser door was opened the bags would fall out of the unit and had to be held by hand. Staff stated they removed the bags from the supporting cardboard boxes to assist in temperature control. Contact the manufacturer of the dispenser to obtain rigid bag supports to install in these units.
Recommendation:
Item No.: 19
Site: Provisions-Dairy Walk-in Refrigerator
Violation: There was an active water leak from a deckhead hatch in the dairy walk-in refrigerator. Water drops were observed on the box of bagged milk stored on the pallet directly below. Staff immediately moved the boxes so they were not below the leaking water.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 37
Site: Provisions-Dairy Walk-in Refrigerator
Violation: There was an active water leak from a deckhead hatch in the dairy walk-in refrigerator.
Recommendation: Ensure the source of the leak is found and repaired.
Item No.: 39
Site: Buffet-Windjammer Buffet - Fruit/Soup Island
Violation: One live filth fly was observed at the fruit and soup island.
Recommendation: Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 33
Site: Buffet-Dog House Beverage Counter
Violation: The deckhead over the portable table with coffee, tea, and water for passenger self-service was not completely covered, as there were 3/4 inch gaps present between the painted metal panels. Above that deckhead was what appeared to be wiring, insulation, and piping of with an unknown source. Additionally, the deck juncture with the bulkhead behind the table was not coved.
Recommendation: Verify the water source for the piping over the deckhead. If that source is non-potable the table should be moved away from that piping. Close the deckhead so dust and other debris from the overhead is able to reach the drink counter below. Cove the deck juncture with the bulkhead behind the table.
Item No.: 36
Site: Buffet-Dog House Beverage Counter
Violation: The artificial light level at the portable table for the self-service beverages was less than the minimum 220 lux. There were no light fixtures in the deckhead over the beverage table.
Recommendation: Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 19
Site: Buffet-Dog House Beverage Counter
Violation: The exposed utilities and the unknown piping over the partly closed dechead above the passenger self-service beverage counter was not protective of the beverage dispensers or clean cup storage containers.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 26
Site: Bar-Lobby Bar
Violation: There was a visible mold present from swabs taken from interiors of the two in-use beer dispensing taps.
Recommendation: Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized. Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 36
Site: Bar-Cafe' Latitudes
Violation: The artificial light level behind the espresso machine on the back bar counter was below the minimum 110 lux. There were some overhead lights present in the cabinet of the back bar but they were controlled by a much larger area system.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment. Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars. In bars and dining room waiter stations, provide 220 lux (20 foot candles) light intensity during cleaning operations.
Item No.: 44
Site: Medical-Reportable Case Definition
Violation: A deck department crew member who was listed as non-reportable during the current voyage, presented to medical with 2 diarrhea episodes and was issued anti-diarrheal medication and isolated for 24 hours from the last symptom. When questioned by the inspector, staff were unaware that a reportable case definition can be diarrhea episodes that are above normal for the individual. No remarks were in this patient's file that indicated that these symptoms were normal for the individual.
Recommendation: Ensure the supervisor or person in charge of medical operations related to AGE on the vessel demonstrates to VSP?during inspections and on request?knowledge of medical operations related to AGE, is able to demonstrate this knowledge by compliance with Section 4 of the VSP 2011 Operations Manual or by responding correctly to the inspector?s questions as they relate to the specific operation, and properly trains employees to comply with Section 4 of the VSP 2011 Operations Manual as it relates to their assigned duties.
Item No.: 01
Site: Medical-Reporting
Violation: The 24 and 4 hour reporting being automatically submitted by the electronic medical database was reporting incorrect passenger and crew counts for several recent voyages. The current voyage from 6 - 13 September reported 2187 passengers and 911 crew members when in reality the cruise began with 2152 passengers and 897 crew members. On the voyage from 9 - 16 August, the 24 hour report listed 2,419 passengers and 903 crew members, but when the cruise began, there were only 2,385 passengers and 871 crew members.
Recommendation: Ensure that the count of on board passengers and crew is accurate for each voyage and that all other information on cases is accurate. A corporate review should be made immediately to understand and correct the error generated by the electronic medical record system.
Item No.: 19
Site: Other-Forward Port Side Luggae Trolley Storgae
Violation: Approximately, 5 wooden pallets, each with 20 boxes of dried soup noodles were being stored against the bulkhead in this area. Supports have been installed in order to hang vinyl curtains to provide separation from the open deck area. A mop and a broom/dust pan were stored in contact with the food pallets and there was an accumulation of dust debris on the deck where the pallets were stored. This area is not constructed to food storage standards and is a high traffic area. A similar violation was written on the previous inspection.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 19
Site: Other-Starboard and Port Provision Corridor
Violation: Three pallets, each with approximately 5 large boxes of individually packaged chips were stored up against the main provisioning door in this area. According to staff, the chips have been stored in this area for the previous 2 cruises or 14 days. The deckhead above the food items was open to numerous wires and hydraulic piping to the door. Pallets of boxed water was also stored at the same location on the port side. These food items were moved to an area within this main provisioning corridor which was finished to storage standards.
Recommendation: Protect food from contamination by storing the food: (1) Covered or otherwise protected; (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination; and (4) At least 15 centimeters (6 inches) above the deck.
Item No.: 08
Site: Potable Water-Technical Filling Deck 3 FZ 5
Violation: A rubber mat was placed around the air gap at this location in order to minimize excessive splashing.
Recommendation: Remove the rubber mat to ensure an uninterrupted space at the air-gap. A wider funnel could be installed to address splashing at the lower pipe connection.
Item No.: 10
Site: Recreational Water Facilities-Whirlpool Antientrapment
Violation: It was unclear whether the two suction drain covers at each of the two newly installed whirlpools were compliant with ASME A112.19.8 requirements. Also, each of the whirlpools had 2 suction drains that were less than 3 feet apart and had no secondary anitentrapment feature such as an SVRS or APS. According to staff, these whirlpools were installed in August 2013.
Recommendation: For RWFs with suction fittings and a single blockable drain or multiple drains (less than 3 feet apart), provide an ASME A112.19.8 compliant antientrapment/antientanglement drain cover and a safety vacuum release system or automatic pump shut-off system.
Item No.: 10
Site: Recreational Water Facilities-Kids Pool and Slide
Violation: There were no chart recorder records for the chlorine residual and pH monitoring for the kids water slide since April 2013. Only some of the water circulation for the pool and slide are combined, and the combined parts involve the compensation tank. To be treated as one combined system the water from the pool would fully supply the slide and all the water returning from the slide should drain directly back to the pool. As designed there should be individual monitoring and recording from the slide and the pool.
Recommendation: Install chart recorders or electronic data loggers with security features that record pH and halogen measurements for each individual RWF. Ensure the sample line for the analyzer probe (monitoring) is either directly from the RWF or on the return line from each RWF and before the compensation tank. Install appropriate sample taps for analyzer calibration. In the event of equipment failure, measure free residual halogen and pH by a manual test kit at the RWF or return line at least hourly for whirlpool spas, spa pools, children?s pools, and wading pools and every 4 hours for all other RWFs. Record manual readings on a chart or log, retain for at least 12 months, and ensure that they are available for review during inspections. Complete repairs on malfunctioning halogen analyzer-chart recorders within 30 days of equipment failure. Provide an audible alarm in a continuously occupied watch station to indicate low and high free halogen and pH readings in each RWF.