Item No.:
*
|
|
Site:
*General Comments-Commendation
|
|
Violation:
The Celebrity Solstice's teams managing their medical center, potable water, recreational water, housekeeping, HVAC, IPM, child activity center and food safety programs deserve special recognition and commendation for their outstanding compliance with the USPHS/ VSP Operations Manual observed during today's detailed operational inspection.
|
|
Recommendation:
Keep up the good work!
|
|
|
Item No.:
11
|
|
Site:
Medical-Food Worker Reporting
|
|
Violation:
A cook became ill with acute gastroenteritis symptoms at 22:30 on 22 June 2014. After experiencing symptoms, contrary to the ship's policies and training and the VSP Operations Manual, the worker reported to work without informing the supervisor of the illness. This worker did not report the illness to the medical center until 09:39 on 23 June 2014. This worker was immediately terminated from employment.
|
|
Recommendation:
Ensure food employees who have conditions or symptoms of diarrhea and/or vomiting report these conditions or symptoms to the vessel's medical staff and are restricted from working with exposed food, warewashing, clean equipment, utensils, and linens, and unwrapped single-service and single-use articles.
|
|
|
Item No.:
17
|
|
Site:
Galley-Deck 3 - Garde Manger
|
|
Violation:
The cooling logs were not completed for boiled eggs on 28 June. No temperatures were written at 10:57 and 12:25. The log was initialed by the person responsible.
|
|
Recommendation:
Ensure the cooling temperatures of cooked potentially hazardous foods are documented. Potentially hazardous foods shall be cooled from 57°C (135°F) to 21°C (70°F) or less within 2 hours and from 21°C (70°F) to 5°C (41°F) or less within an additional 4 hours.
|
|
|
Item No.:
26
|
|
Site:
Galley-Deck 3 - Garde Manger
|
|
Violation:
The back plate of the previously cleaned food slicer was soiled with food debris. When moved, colored liquid poured from the slicer. A crew member immediately began cleaning the slicer.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Galley-Hot Galley
|
|
Violation:
On the right flat grill, the grease tray housing was soiled with food debris and standing water. The grill and housing had been previously cleaned.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Oceanview Cafe - Stir Fry Station
|
|
Violation:
To the left of the oven, the middle bulkhead panel was misaligned. The right side of this panel was spot welded, exposing seams. There was a large hole at the lower area of the panel, leading into a void space. Staff stated the wires for the newly installed flat grill were being replaced.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
36
|
|
Site:
Bar-Deck 4 - Martini Bar
|
|
Violation:
The bar was in operation during the inspection. The normal operating lights only provided 50 lux at the bar counter's handwashing sink. The lights could be adjusted to a brighter illumination which was demonstrated to the inspection team.
|
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) at handwashing stations in bars.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Oceanview Cafe - Line 2 Port Aft
|
|
Violation:
The light intensity was less than 220 lux at the flat grill and preparation counter.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
38
|
|
Site:
Galley-Oceanview Cafe - Potwash Area
|
|
Violation:
A broom and dustpan were stored near the soiled storage. The area was in operation during the inspection. These items were moved to the cleaning locker.
|
|
Recommendation:
Ensure maintenance tools such as mops, brooms, and similar items are stored in a designated locker so they do not contaminate food, food-contact surfaces of utensils, and equipment, linens, and single-service and single-use articles.
|
|
|
Item No.:
39
|
|
Site:
Galley-Deck 4 - Pastry
|
|
Violation:
One live fly was near the small elevator. The area was in operation during the inspection.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|