Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Carnival Splendor Cruise Line: Carnival Cruise Lines, Inc. Inspection Date: 07/16/2015 Inspection Score: 97
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Potable Water-Engine Room - Fin Stabilizer
Violation: The potable water line, before the reduced pressure zone backflow preventer for the transfer to the technical water, was not striped blue every 5 meters.
Recommendation: Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers.
Item No.: 26
Site: Pantry-Deck 7 - Starboard Pantry
Violation: Black sediment was noted in the recirculating water bath of the ice machine, directly below the pump. This was noted on the last inspection. Staff reported they were replacing all ice machines onboard, and had a requisition order which stated two units would be replaced each month.
Recommendation: Ensure food contact surfaces of equipment and utensils are clean to sight and touch. Ensure food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 36
Site: Buffet-Taste of Nations - Staboard
Violation: The artificial light level between the conveyor toaster oven and the bulkhead beside was below the minimum 110 lux.
Recommendation: Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
Item No.: 33
Site: Galley-Taste of Nations - Center Galley
Violation: A condensate drip from the deckhead-attached fire detector was observed in walk-in refrigerator #66. Water was dripping to the deck below the detector in the center of this room.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
Item No.: 39
Site: Other-Steakhouse Show Kitchen
Violation: A live fruit fly was observed on the deckhead near the handwash station. The area was not in use at the time of inspection.
Recommendation: Effectively control the presence of insects to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
Item No.: 21
Site: Room Service-Room Service Galley - Deck 6
Violation: A gap was observed between the lower half of the door and the frame when fully closed that allowed a set of folded papers to be passed from the outside to the inside of the three door undercounter reach-in refrigerator #6.9506B. The gap was greatest on the leftmost door of this undercounter refrigerator. Staff stated that there was a full ship assessment of the refrigerators with a solution planned that involved new doors, door gaskets, and latches.
Recommendation: Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 33
Site: Galley-Main Galley - Bakery
Violation: A layer of frozen condensate was noted inside the deckhead light fixture to the inside left of the walk-in freezer #37 entry door. Additionally, a pool of frozen condensate was on the top storage shelf to the left of the entry door inside this same walk-in freezer. No food was contacted.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair. Ensure decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas are cleaned as often as necessary.
Item No.: 33
Site: Bar-Liner Aft Bar
Violation: A rough surface was noted on most of the deckhead panels over the front bar area due to a weathering. The weathering was causing the laminated covering over each panel square to peel away in spots which extended from the panels. A rough and difficult to clean surface was created.
Recommendation: Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, bars, and food and equipment storage areas are constructed and maintained for easy cleaning.
Item No.: 28
Site: Galley-Taste of Nations Galley - Dishwash
Violation: An employee was observed with a wiping cloth inside a cleaned cup in the pre-check area beside the active dishwashing machines. The inspector checked the cloth and it was wet. Before the final meeting the inspector returned to the same dishwash and another staff member was observed drying just cleaned cups again in the pre-check dishwash area. The cloth was again wet. The same violation was noted in the 30 November inspection of the ship in the same dishwash area.
Recommendation: Launder linens that do not come in direct contact with food between operations if they become wet, sticky, or visibly soiled.
Item No.: 22
Site: Galley-Main Galley - Dishwash
Violation: Staff had set several grey plastic bins filled with soiled cups and mugs set directly on the deck before washing.
Recommendation: Ensure drainboards, utensils, racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation are provided for necessary utensil holding before cleaning and after sanitizing.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program