Item No.:
33
|
|
Site:
Food Service General-Decks
|
|
Violation:
Deck tile grouting was either missing, recessed, or cracked which prevented the area from being easily cleaned in the following food service areas: crew galley, vegetable preparation room, fish preparation room, Windjammer aft grill line, Chops show galley, Viking Lounge Bar, and throughout the hot galley section of the main galleys. Several areas of newly grouted decks were observed throughout other areas of the main galleys and were in excellent condition.
|
|
Recommendation:
Ensure decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are maintained in good repair.
|
|
|
Item No.:
36
|
|
Site:
Buffet-Crew Mess
|
|
Violation:
There was less than the required 220 lux of light at the self-service cereal station located adjacent to the main self-service buffet.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in consumer self-service areas.
|
|
|
Item No.:
15
|
|
Site:
Provisions-Dry Store Room #1
|
|
Violation:
There was a dent at the top seam of a can of hoisin sauce. The can was discarded.
|
|
Recommendation:
Ensure canned goods with dents on end or side seams are not used.
|
|
|
Item No.:
20
|
|
Site:
Preparation Room-Potato Tumbler
|
|
Violation:
There was an approximate 3/4 inch lengthwise tear in the fiberglass lid to the potato tumbler making the area difficult to clean.
|
|
Recommendation:
Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices.
|
|
|
Item No.:
36
|
|
Site:
Preparation Room-
|
|
Violation:
The deckhead light above the handwash station and the preparation sink was burnt out resulting in less than the required 220 lux of light. This was corrected during the inspection.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation and handwashing facilities.
|
|
|
Item No.:
34
|
|
Site:
Preparation Room-Fish Preparation
|
|
Violation:
The drain line to the handwashing sink was not properly connected and allowed water to spray along the deck when engaged.
|
|
Recommendation:
Ensure a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
26
|
|
Site:
Buffet-Aft Beverage Stations
|
|
Violation:
There was a yellow sticky residue immediately above the water activating lever to the ice/water machine at both the starboard and port aft beverage stations. The accumulation of the yellow residue was in excess of the morning breakfast service period and according to staff, the residue was juice concentrate left over from mixing pitchers at the station. These areas were cleaned.
|
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
|
Item No.:
33
|
|
Site:
Buffet-Starboard Mid Beverage Station
|
|
Violation:
There was an open old electrical penetration in the bulkhead immediately below and to the right of the handwash station. There was also an open seam around the water line penetration at the same area. Both of these openings led to a void space.
|
|
Recommendation:
Ensure bulkheads in food preparation areas are maintained in good repair.
|
|
|
Item No.:
21
|
|
Site:
Other-Johnny Rockets
|
|
Violation:
The soda lines in the technical compartment to the soda dispensing machine in the dining area were not wrapped or encased in an easily cleanable material. The lines were not observed soiled, but they presented a difficult to clean area.
|
|
Recommendation:
Ensure nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
20
|
|
Site:
Galley-Deck 5 - Potwash
|
|
Violation:
A metal deep fry basket at the soiled landing had several broken and unattached wires making the equipment hard to clean and a potential hazard to break apart during cooking. The basket was discarded.
|
|
Recommendation:
Design and construct food contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions.
|
|
|
Item No.:
27
|
|
Site:
Galley-Deck 3 - Garde Manger
|
|
Violation:
The ends of the sliding arm to the pusher plate and the area where the pusher plate attaches to the sliding arm of the deli slicer were soiled with an accumulation of old food residue. The deli slicer had been previously cleaned. This was cleaned during the inspection.
|
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
39
|
|
Site:
Galley-Deck 3 - Garde Manger
|
|
Violation:
There was a live fruit fly in the walk-in dry store room.
|
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
34
|
|
Site:
Galley-Deck 3 - Hot Galley
|
|
Violation:
The drain line to the handwashing sink nearest the sauce station had a significant water leak when the water was engaged. Once engaged the water sprayed along the deck below.
|
|
Recommendation:
Ensure a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
37
|
|
Site:
Galley-Deck 3 - Sauce Station
|
|
Violation:
A sauce cooking in an uncovered tilting pressure cooker was brought to a boil which allowed for steam to escape and condense to collect on the deckhead above. The lid to the cooker was open and left unattended. No food was impacted by dripping condensate.
|
|
Recommendation:
Keep lids closed on actively cooking and unattended cooking kettles and similar equipment. Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent condensation from collecting on bulkheads and deckheads.
|
|
|
Item No.:
36
|
|
Site:
Galley-Deck 3 - Sauce Station
|
|
Violation:
The light intensity was less than the required 220 lux of light at the handwash station near the combination oven.
|
|
Recommendation:
Ensure the light intensity is at least 220 lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck at handwashing facilities.
|
|
|
Item No.:
33
|
|
Site:
Other-Cafe Promenade
|
|
Violation:
The deck inside the technical compartment to the counter mounted espresso machine had a buildup of old coffee grounds and brown standing water. This was cleaned during the inspection.
|
|
Recommendation:
Ensure decks in food preparation areas are cleaned as often as necessary.
|
|
|
Item No.:
34
|
|
Site:
Other-Ben and Jerry's
|
|
Violation:
The drain line to the handwashing sink was not connected to the hand sink basin which allowed water to run to the deck and inside the technical compartment where the drain line was located. The amount of standing water on the deck outside the technical compartment indicated that the plumbing had been disconnected for a period of time.
|
|
Recommendation:
Ensure a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Other-Cafe Promenade
|
|
Violation:
There was an open gap where the water line to the soda gun penetrated the bulkhead inside the technical compartment where the soda compressor was located.
|
|
Recommendation:
Ensure bulkheads in food preparation areas are maintained in good repair.
|
|
|
Item No.:
02
|
|
Site:
Medical-Accute Gastrointestinal Illness Recording / Reporting System
|
|
Violation:
The software tracking illness records and generating illness reports has errors in the way it is reporting passenger and crew totals. For example, on the voyages #25491 (03/31 - 04/07/2013), #25490 (03/24 - 03/31/2013) and #25489 (03/17 - 03/24/2013) the required gastrointestinal illness log listed 1909 crew members on each voyage. The actual number of crew members were about 700 less or 1218, 1218 and 1184, respectively. For the most recent voyage #25493, this erroneous number actually made it into the ship's GI report, though it was not recorded on the log. Differences in the passenger totals were also noticed with a higher passenger count. This was often noted on the records from booked passengers used by the system rather than actual passengers for these voyages. An example of this discrepancy may be found on voyage #25489 (03/17 - 03/24/2013), where there were over 40 fewer passengers on the 4-hour report than the 24-hour report.
|
|
Recommendation:
Maintain a daily, standardized AGE surveillance log for each cruise by the master of the vessel, the medical staff, or other designated staff.
|
|
|
Item No.:
42
|
|
Site:
Children Area-Toy Cleaning
|
|
Violation:
Soil was noted in cracks and crevices of large toys in the main play room where wiping with cloths was being used for cleaning these toys. The larger surfaces were very clean, but these recesses were not being cleaned and disinfected by this cleaning method.
|
|
Recommendation:
Ensure toys used in the child-activity center are maintained in a clean condition.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-Tank Maintenance
|
|
Violation:
The required third-party certification of the coating used in the potable water tank maintenance was not available. This was downloaded during the inspection from the certification organization's website and placed alongside the manufacturer's application information in the ship's record system.
|
|
Recommendation:
Ensure the interior coatings on potable water tanks are approved for potable water contact by a certification organization. Follow all manufacturers? recommendations for application, drying, and curing. For the tank coatings used, maintain the following onboard: (1) written documentation of approval from the certification organization (independent of the coating manufacturer).
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-Safety Signs
|
|
Violation:
The bather load numbers had been removed from the sign in Pool #3. The correct values were posted at all other recreational water facilities examined. The correct numbers were also noted in the calculations in the recreational water facility records.
|
|
Recommendation:
Provide safety signs for all RWFs, except for baby-only water facilities. Ensure the signs, at a minimum, include the following words: (4) bather load #.
|
|
|
Item No.:
11
|
|
Site:
Medical-Crew Illness Reporting
|
|
Violation:
A galley worker had an 8-hour lapse in reporting an onset of gastrointestinal illness symptoms during voyage #25490. The ship did issue a disciplinary action to this worker for the late reporting.
|
|
Recommendation:
Ensure food employees who have conditions or symptoms of diarrhea report these conditions or symptoms to the vessel's medical staff and are restricted from working with exposed food, warewashing, clean equipment, utensils, and linens, and unwrapped single-service and single-use articles.
|
|