|
Item No.:
*
|
Site:
Medical-Electronic Medical Surveillance System
|
Violation:
A crew member experienced acute gastroenteritis symptoms and reported to the medical center on 4 March. During his 5 March follow-up interview with medical staff, the electronic medical surveillance system indicated his last symptom was 22 March at 10pm. His actual last symptom was 4 March at 10pm.
|
Recommendation:
|
|
Item No.:
06
|
Site:
Potable Water-Microbiological Records
|
Violation:
Locations for the monthly microbiological samples often repeated each month. For example: (1) Johnny Rockets dishwash was tested 13 January, 27 January, and 10 February; (2) one nurse's cabin handwash station was tested 13 January and 17 March; (3) another nurse's cabin handwash station was tested 3 February and 10 March; (4) the Environmental Officer's cabin handwash station was tested 27 January and 17 February. The section where these results were recorded was titled 'Water Taps and Water Fountains.' It was unclear if samples were obtained from different water sources.
|
Recommendation:
Collect and analyze a minimum of four potable water samples per month for the presence of E. coli. Collect samples from the forward, aft, upper, and lower decks of the vessel. Change the sample sites each month so that all of the potable water distribution system is effectively monitored. Conduct follow-up sampling for each positive test result.
|
|
Item No.:
08
|
Site:
Bar-Deck 11 - Pool Bar
|
Violation:
Carbonator backflow preventer on the right carbonator did not have a visible atmospheric vent.
|
Recommendation:
Install backflow prevention devices with atmospheric vents when air gaps are impractical or when water under pressure is required.
|
|
Item No.:
08
|
Site:
Potable Water-Port Side Aft Bunker Station
|
Violation:
The technical water fill line from production was less than two times the diameter of the inlet pipe. The inlet pipe measured 90 millimeters but the gap was only 130 millimeters.
|
Recommendation:
Ensure air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 25 millimeters (1 inch).
|
|
Item No.:
08
|
Site:
Potable Water-Engine Cross Connection Control Plan
|
Violation:
The cross connection between the technical water and the distillate water was not included on the list of backflow preventers. Staff stated there was an air gap.
|
Recommendation:
Ensure the cross-connection control program includes at a minimum: a complete listing of cross-connections and the backflow prevention method or device for each, so there is a match to the plumbing system component and location. Include air gaps on the listing. Ensure a schedule for inspection frequency is set. Maintain a log documenting the inspection and maintenance in written or electronic form, and ensure it is available for review during inspections.
|
|
Item No.:
08
|
Site:
Potable Water-Forward Port Bunker Station
|
Violation:
The bottom filling hose connected to the filling line was not labeled 'potable water only' at the connecting end. A label further down the line had been rubbed off and was difficult to read.
|
Recommendation:
Ensure each bunker station potable water filling line is striped or painted blue or in accordance with the color designation in ISO 14726 (blue/green/blue) and clearly labeled "POTABLE WATER FILLING" in letters at least 13 millimeters (0.5 inch) high, stamped on a noncorrosive label plate or the equivalent, and located at or near the point of the hose connection.
|
|
Item No.:
08
|
Site:
Potable Water-Engine Room Mineralizer
|
Violation:
A distillate line was striped blue/grey/blue but was also affixed with a label stating 'fresh water (potable)'.
|
Recommendation:
Stripe or paint potable water lines either in accordance with ISO 14726 (blue/green/blue) or blue only. Stripe or paint distillate and permeate lines directed to the potable water system in accordance with ISO 14726 (blue/gray/blue). Ensure no other lines have the above color designations. Stripe or paint these lines at 5 meters (15 feet) intervals and on each side of partitions, decks, and bulkheads, except where decor would be marred by such markings, including potable water supply lines in technical lockers. Do not stripe or paint potable water lines after reduced pressure assemblies as potable water. Uniquely identify all refrigerant brine lines in all galleys, pantries, and cold rooms to prevent cross-connections.
|
|
Item No.:
08
|
Site:
Potable Water-Engine Room Pump Room #1 Port
|
Violation:
The backflow preventer on the potable water line to the right of the handwash station was continuously leaking from the atmospheric vent.
|
Recommendation:
Maintain backflow prevention devices in good repair.
|
|
Item No.:
19
|
Site:
Galley-Deck 3 - Vegetable Station
|
Violation:
A crew member working in walk-in refrigerator 3800-4 placed three cans of food on the deck before taking them out of the area.
|
Recommendation:
Protect food from contamination by storing the food: (4) At least 15 centimeters (6 inches) above the deck.
|
|
Item No.:
19
|
Site:
Galley-Deck 3 - Vegetable Station
|
Violation:
An unlabeled plastic container of yellow powder was on the counter. Staff stated it was potato.
|
Recommendation:
Ensure containers holding food or food ingredients that are removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar are identified with the common name of the food.
|
|
Item No.:
19
|
Site:
Provisions-Eggs 1876
|
Violation:
Condensation slowly dripped from the deckhead vent onto one box of eggs.
|
Recommendation:
Protect food from contamination by storing the food: (2) In a clean, dry location; (3) Where it is not exposed to splash, dust, or other contamination.
|
|
Item No.:
20
|
Site:
Galley-
|
Violation:
Hot holding unit #2003 had been out of service for about one month.
|
Recommendation:
Food contact equipment must be maintained in good repair and proper adjustment: (1) Equipment must be maintained in a state of repair and condition that meets the materials, design, construction, and operating specifications of these guidelines.
|
|
Item No.:
20
|
Site:
Galley-Deck 3 - Beverage Station
|
Violation:
At the soda dispenser next to the ice machine, the underside of the far right dispenser had four slotted fasteners in the food splash area. Staff explained the soda technician was recently onboard. A crew member immediately replaced the plastic panel to cover these fasteners.
|
Recommendation:
Use only low profile, nonslotted, noncorroding, and easy-to-clean fasteners on food-contact surfaces and in splash zones. Prohibit the use of exposed slotted screws, Phillips head screws, or pop rivets in these areas.
|
|
Item No.:
20
|
Site:
Galley-Deck 3 - Beverage Station
|
Violation:
Inside the ice machine next to the office, the plastic ice thickness sensor panel was cracked above the below the fastener.
|
Recommendation:
Design and construct food contact surfaces of equipment and utensils to be durable and to retain their characteristic qualities under normal use conditions. Ensure multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams greater than 0.8 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections.
|
|
Item No.:
21
|
Site:
Galley-Deck 11 - Giovanni's Restaurant
|
Violation:
The ice dispenser in the beverage pantry had a large chip out of the plastic drip tray exposing styrofoam insulation on the right front corner. The drip tray was pulling away from the stainless body of the dispenser creating a difficult to clean seam.
|
Recommendation:
Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
|
|
Item No.:
22
|
Site:
Galley-Deck 11 - Windjammer - Dishwashing
|
Violation:
The glasswasher final rinse manifold had an ineffective spray pattern. The upper manifold had the third nozzle from the door side of the machine clogged . Additionally, this final rinse manifold initially was not firmly mounted in the pipe connections and some water flow was lost around this joint during the first trial.
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
|
|
Item No.:
22
|
Site:
Preparation Room-
|
Violation:
The undercounter dishwash machine was out of service starting the morning of the inspection.
|
Recommendation:
Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines.
|
|
Item No.:
22
|
Site:
Galley-Deck 3 - Hot Line
|
Violation:
The bucket of sanitizing solution was soiled.
|
Recommendation:
Ensure the wash, rinse, and sanitize solutions are maintained clean.
|
|
Item No.:
22
|
Site:
Galley-Deck 3 - Pantry
|
Violation:
The bucket of sanitizing solution had an oily layer on top.
|
Recommendation:
Ensure the wash, rinse, and sanitize solutions are maintained clean.
|
|
Item No.:
24
|
Site:
Galley-Staff Mess Dishwash
|
Violation:
The temperature of the final sanitizing rinse nozzles did not reach 180F during three measurements. Temperatures at the upper nozzles were 165F, 160F, and 172F. The technician increased the steam and the final sanitizing rinse nozzle temperature measured 183F.
|
Recommendation:
In a mechanical operation, ensure the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90C (194F) or less than: (1) 74C (165F) for a stationary rack, single-temperature machine; (2) 82C (180F) for all other machines. Ensure the utensil surface temperature is not less than 71C (160F) as measured by an irreversible registering temperature indicator.
|
|
Item No.:
26
|
Site:
Galley-Deck 12 - Johnny Rocket's Restaurant
|
Violation:
The ice machine had black particles in the right side of the recirculating ice bath. Mold was found in the upper right corner of the evaporator plate's plastic housing / ice maker compartment seam near the sealant.
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
Item No.:
26
|
Site:
Housekeeping-Deck 10 - Ice Pantry Midship
|
Violation:
A small amount of mold was found in the upper left corner of the evaporator plate's plastic housing / ice maker compartment seam.
|
Recommendation:
Ensure food contact surfaces of equipment and utensils are clean to sight and touch.
|
|
Item No.:
27
|
Site:
Bar-Deck 11 - Pool Bar
|
Violation:
A large mobile blue plastic bar counter had soil in the many seams around the top counter and bottom of the front plastic sneeze shield. Additionally, a used straw wrapper was found in the hole of the pipe holding up the blue plastic overshelf.
|
Recommendation:
Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
Item No.:
29
|
Site:
Galley-Deck 3 - Dishwash
|
Violation:
A green apron was stored on the handwash station at the soiled end of the dishwash machine.
|
Recommendation:
Ensure handwashing facilities are used for no other purpose and are accessible at all times.
|
|
Item No.:
30
|
Site:
Food Service General-Handwash Stations
|
Violation:
Many handwash station faucets were continuously leaking. This was mostly observed in the deck 3 and 4 main galleys. In the staff mess dishwash, the bucket fill tap was continuously leaking.
|
Recommendation:
Keep handwashing facilities clean and in good repair.
|
|
Item No.:
33
|
Site:
Buffet-Deck 11 - Windjammer - Lines #2 and #3
|
Violation:
The galvanized channels of the fire door track at the deck were severely corroded making them difficult to clean.
|
Recommendation:
Ensure decks / bulkheads in food areas are maintained in good repair.
|
|
Item No.:
36
|
Site:
Galley-Deck 5 - Pastry
|
Violation:
The lights were not working behind the deck oven.
|
Recommendation:
Ensure the light intensity is at least 110 lux (10 foot candles) behind and around mounted equipment, including counter-mounted equipment.
|
|
Item No.:
37
|
Site:
Provisions-Eggs 1876
|
Violation:
Condensation slowly dripped from the deckhead vent onto one box of eggs.
|
Recommendation:
Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
|
|
Item No.:
37
|
Site:
Galley-Deck 3 - Dishwash
|
Violation:
At the soiled end of the dishwash machine, excess condensation accumulated on the deckhead and was dripping onto the machine. Condensation also accumulated in the deckhead vent along the length of the machine.
|
Recommendation:
Ensure exhaust ventilation hood systems in food preparation and warewashing areas--including components such as hoods, fans, guards, and ducting--are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles. Ensure ventilation hood systems and devices are sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
|
|
Item No.:
39
|
Site:
Galley-
|
Violation:
One fly was near the back preparation counter.
|
Recommendation:
Effectively control the presence of insects, rodents, and other pests to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
Item No.:
39
|
Site:
Galley-Deck 11 - Windjammer - Hot Galley
|
Violation:
More than 50 white sugar ants, identified by the ship's IPM team, were found on the portable table to the left of the two tilting skillets, on outside of the bulk dry storage containers for cocoa powder, corn meal and corn starch, and on the bulkhead extending to the corner next to the tilting kettle. The food products were all discarded by the ship staff, this section of the hot galley was closed and cleaned, followed by the IPM staff treating the area and planning necessary follow-up.
|
Recommendation:
Effectively control the insects to minimize their presence in the food areas aboard a vessel.
|
|
Item No.:
42
|
Site:
Children Area-Deck 12 - Adventure Ocean
|
Violation:
Three of the rolling toys were soiled in the active play area for 3 - 5 year old children. Heavy soil and debris was found in the seams of the slide landing area and under the removable landing pad. A heavy layer of dust was found on the wooden baseboard outside the entrance to the slide play area. The carpet around the edges of the interior of this play space also had debris.
|
Recommendation:
Ensure toys used in the child-activity center are maintained in a clean condition. Vacuum carpets daily and clean periodically when visibly soiled.
|
|
Item No.:
43
|
Site:
Ventilation-Deck 9 - Fan Room Mid-ship
|
Violation:
Two of the units did not have accessible condensate collection pans for inspection. The third unit had an access panel that lead to the coil area, but the condensate collection pan was again, not accessible for inspection.
|
Recommendation:
Ensure air handling unit condensate drain pans and collection systems are able to be accessed for inspection, maintenance, and cleaning. Install sight windows or use other effective methods to allow for full inspection of condensate collection pans when original equipment access makes evaluation during operational inspections impractical.
|
|