Cruise Ship: Seven Seas Explorer Cruise Line: Regent Seven Seas Inspection Date: 01/28/2020 Inspection Score: 95
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 20
Site: Preparation Room-Cold Room 16
Violation: The ambient temperature of this unit was 58'F. This made the temperature of the cut melons needing temperature control for food safety to be 54'F.
Recommendation: Ensure equipment for cooling and heating food, and holding cold and hot food, is sufficient in number and capacity to maintain potentially hazardous food temperatures.
Item No.: 11
Site: Medical-Acute Gastroenteritis (AGE) Employee Reporting
Violation: There was a food handler who listed AGE symptom onset of 08 January at 1300 but did not report to medical until 09 January. The employee worked while symptomatic but did not handle food. Nonetheless, a food assessment form was completed, stating that the clean dishes handled by the ill employee were re-washed. Additionally, the employee visited the crew mess while symptomatic. Corrective action was taken.
Recommendation: When food employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 48 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document date and time of last symptom and clearance to return to work. When nonfood employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document the date and time of last symptom and clearance to return to work. Ensure the food employee's supervisor or person in charge conducts an assessment of food prepared or served by the food employee while symptomatic and take appropriate corrective actions. Document corrective actions taken as a result of the assessment. Maintain records for 1 year and make them available for review during inspections. Review [when possible] any AGE cases among passengers or crew reported after the ill food employee?s symptom onset for epidemiologic link/connection. Appropriate corrective actions could include discarding ready-to eat food, thoroughly cooking raw food, and disinfecting the food area and equipment.
Item No.: 11
Site: Medical-Acute Gastroenteritis (AGE) Employee Reporting
Violation: A nonfood employee had an AGE onset of 02 January at 2200 but did not report to medical until 3 January at 0920. This employee worked for one hour before going to medical. Corrective action was taken.
Recommendation: When nonfood employees meet the case definition for AGE, ensure the following actions are taken: (1) isolate in cabin or designated restricted area until symptom-free for a minimum of 24 hours; (2) follow-up with and receive approval by designated medical personnel before returning crew to work; (3) document the date and time of last symptom and clearance to return to work. Ensure the food employee's supervisor or person in charge conducts an assessment of food prepared or served by the food employee while symptomatic and take appropriate corrective actions. Document corrective actions taken as a result of the assessment. Maintain records for 1 year and make them available for review during inspections. Review [when possible] any AGE cases among passengers or crew reported after the ill food employee?s symptom onset for epidemiologic link/connection. Appropriate corrective actions could include discarding ready-to eat food, thoroughly cooking raw food, and disinfecting the food area and equipment.
Item No.: 13
Site: Other-Culinary Center -Acute Gastroenteritis (AGE) Questionnaire
Violation: The passenger/participant questionnaire (half-page size) did not match the full-page size where it asks if any passenger or cabin mates have had AGE in the last 48 hours. The documents only asked if anyone is experiencing AGE.
Recommendation: Because of the risks for foodborne illness inherent to the food operation, ensure the supervisor or person in charge of food operations on the vessel demonstrates to VSP - during inspections and on request - knowledge of foodborne disease prevention, application of the Hazard Analysis Critical Point principles, and the food-safety guidelines in this manual. Ensure that the person in charge demonstrates this knowledge: (1) By compliance with these guidelines; (2) By being a domestically or foreign certified food protection manager who has shown proficiency of required information through passing a test that is part of an accredited program; or (3) By responding correctly to the inspector's questions as they relate to the specific food operation. Ensure that the areas of knowledge include: (1) Describing the relation between prevention of foodborne disease and personal hygiene of a food employee; (2) Explaining the responsibility of the person in charge to prevent transmission of foodborne disease by a food employee who has a disease or medical condition that may cause foodborne disease; (3) Describing the symptoms associated with diseases that are transmissible through food; (4) Explaining the significance of the relation between maintaining the time and temperature of potentially hazardous food and the prevention of foodborne illness; (5) Explaining the hazards involved in the consumption of raw or undercooked meat, poultry, eggs, and fish; (6) Stating the required food temperatures and times for safe cooking of potentially hazardous food, including meat, poultry, eggs, and fish; (7) Stating the required temperatures and times for the safe refrigerated storage, hot holding, cooling, and reheating of potentially hazardous food; (8) Describing the relation between prevention of foodborne illness and management and control of the following: cross-contamination, hand contact with ready-to-eat foods, handwashing, and maintaining food operations in a clean condition and in good repair; (9) Explaining the relation between food safety and providing equipment that is sufficient in number and capacity as well as properly designed, constructed, located, installed, operated, maintained, and cleaned; (10) Explaining correct procedures for cleaning and sanitizing utensils and food-contact surfaces of equipment; (11) Identifying poisonous or toxic materials on the vessel and the procedures necessary to ensure they are safely stored, dispensed, used, and disposed of according to law; (12) Identifying critical-control points in the operation from purchasing through service that when not controlled may contribute to the transmission of foodborne illness and explaining steps taken to ensure the points are controlled in accordance with the guidelines in this manual.
Item No.: 22
Site: Galley-Deck 4
Violation: The rack-type glasswash was leaking from the steam valve and pooling on the deck. Staff responded immediately to scupper the water off the deck and repairs were completed before the end of the inspection.
Recommendation: Maintain warewashing equipment in good repair and proper adjustment, including: (1) warewashing equipment is maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines; (2) water pressure and water temperature-measuring devices are maintained in good repair and accurate within the intended range of use.
Item No.: 35
Site: Galley-Deck 4
Violation: The rack-type glasswash was leaking from the steam valve and pooling on the deck. Staff responded immediately to scupper the water off the deck and repairs were completed before the end of the inspection.
Recommendation: Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 27
Site: Galley-Deck 4 Bakery
Violation: The backflow prevention device for the water filter equipment used to fill the blender had a build-up of brown and pink debris. Staff responded to immediately clean the device.
Recommendation: Ensure nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 35
Site: Galley-Deck 4
Violation: The gasket on the steam oven was leaking and the water was pooling on the deck. A work order for the equipment was submitted Jan 23, 2020.
Recommendation: Ensure black and gray water is discharged to the vessel's wastewater disposal system and does not pool on the deck.
Item No.: 21
Site: Galley-Deck 4
Violation: The gasket on the stem oven was leaking and the water was pooling on the deck. A work order for the equipment was submitted Jan 23, 2020.
Recommendation: Ensure nonfood contact equipment is maintained in good repair and proper adjustment including: (1) Equipment maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines; (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates are kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 16
Site: Preparation Room-Cold Room 16
Violation: The inspector and crew used tip-sensitive thermometers to measure the temperatures of cut melons in cold room 16. The inspector and crew both measured the melons at 54'F. The melons were under temperature control and there were approximately a dozen trays of melons. The ambient air temperature was 58'F as measured by both the equipment's built-in thermometer and an independent thermometer inside the room. Staff immediately discarded all the trays of cut melons. Staff suspected that the cold storage unit had not been re-programmed from defrosting mode during a time change.
Recommendation: Except during preparation, cooking, or cooling, or when time is used as the public health control, maintain potentially hazardous foods at 57C (135F) or above, except that roasts may be held at a temperature of 54C (130F); or 5C (41F) or less.
*Inspections scores of 85 or lower are NOT satisfactory