Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Rhapsody of the Seas Cruise Line: Royal Caribbean International Inspection Date: 12/04/2005 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 02
Site: Medical-MEDICAL - CLINICAL SPECIMEN SHIPPING REQUIREMENT
Violation: THE SHIP DOES NOT HAVE THE CORRECT OUTER SHIPPING CONTAINERS AND SHIPPING LABELS TO TRANSPORT CLINICAL SPECIMENS UNDER THE IATA AND DOT HAZARDOUS MATERIALS PACKAGING AND SHIPPING REGULATIONS. THE CORRECT ITEMS HAVE BEEN ORDERED BY THE CORPORATE OFFICE AND WILL BE TRANSPORTED TO THE SHIP. THIS IS A NEW REQUIREMENT UNDER THE VSP OPERATIONS MANUAL - 2005.
Recommendation: All clinical specimens shall be packaged and shipped in accordance with the guidelines outlined in Annex 13.4 and the specific details provided in the VSP website. The specimen packaging shall include the proper documentation as required by the receiving laboratory.
Item No.: 09
Site: Recreational Water Facilities-SOLARIUM AND FORWARD POOLS - DECK 9
Violation: THIS SEAWATER POOL MEETS THE VSP DEFINITION OF A SPA POOL AND HAD A FREE CHLORINE RESIDUAL OF ONLY 1.84 PPM DURING THE INSPECTION. THE FOUNTAIN FEATURES IN THE FORWARD POOL MAY ALSO MEET THIS DEFINITION, BUT THE VSP WILL MAKE A FURTHER REVIEW FOR THAT POOL SPECIFICALLY. THIS IS A NEW REQUIREMENT UNDER THE 2005 VSP OPERATIONS MANUAL.
Recommendation:
Item No.: 10
Site: Recreational Water Facilities-SOLARIUM AND FORWARD POOLS - DECK 9
Violation: THE SEAWATER SOLARIUM POOL MEETS THE VSP DEFINITION OF A SPA POOL. THE FILTER MAINTENANCE (MONTHLY CORE SAMPLE/INSPECTION AND BACKWASHING DAILY) WERE NOT PERFORMED ACCORDINGLY. THIS IS A REQUIREMENT IN THE 2005 VSP OPERATIONS MANUAL. THE FOUNTAIN FEATURE ON THE FORWARD POOL MAY ALSO MEET THE SPA POOL DEFINITION, BUT THIS WILL BE FURTHER REVIEWED BY VSP FOR A FINAL DECISION.
Recommendation:
Item No.: 16
Site: Galley-WINDJAMMER HOT GALLEY - TIME AS A CONTROL
Violation: THE SERVICE PERIOD FOR LUNCH ON EMBARKATION DAYS EXCEEDS 4 HOURS, AND TIME ONLY A PUBLIC HEALTH CONTROL WAS USED FOR FOODS HELD IN HOT STORAGE UNITS. SOME OF THE PANS OF GRAVY AND SAUCES ON THE BAIN MARIE WERE NOT LABELED AS FIRST OR SECOND BATCH ACCORDING TO THE WRITTEN TIME AS A PUBLIC HEALTH CONTROL PLAN STATED. ALL PANS WERE LABELED IMMEDIATELY DURING THE INSPECTION.
Recommendation: If time only, rather than time in conjunction with temperature, is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption, ensure that (1) The food is marked or otherwise identified to indicate the time that is 4 hours past the point in time when the food is removed from temperature control; (2) The food is cooked and served, served if ready-to-eat, or discarded, within 4 hours from the time when the food is removed from temperature control; and (3) The food in unmarked containers or packages or marked to exceed a 4 hour limit is discarded.
Item No.: 19
Site: Buffet-WINDJAMMER PORT AND STARBOARD BUFFET
Violation: THERE WAS AN OPEN CHAFING DISH CONTAINING GRAVY AT ONE END OF THE PORT AND STARBOARD BUFFET LINES (AT THE CARVING STATION) FOR PASSENGER SELF-SERVICE. THERE WAS NO SNEEZE SHIELD INSTALLED FOR THE GRAVY CHAFING DISHES AS PROTECTION.
Recommendation: Maintain gravy chafing dishes under a properly designed sneeze shield.
Item No.: 21
Site: Food Service General-BARS AND OTHER FOUNTAIN BEVERAGE STATIONS
Violation: ALL THE NEWER MODEL FOUNTAIN DRINK DISPENSER UNITS HAD SLOT-HEAD SCREWS FASTENED AROUND THE DISPENSER NOZZLES. THIS AREA IS A SPLASH ZONE FOR FOOD CONTACT.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Buffet-WINDJAMMER PORT AND STARBOARD BUFFET
Violation: THE INTERIORS OF THE UNDERCOUNTER CABINETS AND TECHNICAL SPACES THROUGHOUT THE PERMANENT BUFFET ISLANDS WERE UNFINISHED AND HAD DIFFICULT TO CLEAN GAPS, VOIDS, LEDGES, AND EXPOSED UTILITY CONNECTIONS.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-MAIN GALLEY - DK 5 - PASTRY
Violation: TWO BON CHEF DISHES WERE DAMAGED ALONG THE NON-FOOD CONTACT SURFACES, LEAVING OPENINGS BETEEN THE OUTER COATING AND THE PLATE SURFACE, MAKING CLEANING DIFFICULT. THESE ITEMS WERE REMOVED AND DOSPOSED OF DURING THE INSPECTION.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-MAIN GALLEY - DK 5 - COFFEE STATION
Violation: A PREVIOUSLY CLEANED COFFEE MAKER/URN WAS FOUND RETAINING WATER IN THE SPACE BETWEEN THE INNER AND OUTER COMPARTMENTS. THE WATER WAS MOST LIKE FROM THE CLEANING AND SANITIZING OPERATIONS AND ENTERED THE SPACE THROUGH OPENINGS WHERE COMPONENTS, SUCH AS HANDLES, ATTACH TO THE SIDES OF THE UNIT.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-CREW GALLEY
Violation: ALL OF THE HINGE COVERS WERE MISSING FROM THE HOT HOLDING CABINET LOCATED NEXT TO THE BLAST CHILLER, LEAVING OPENINGS, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 24
Site: Galley-WINDJAMMER HOT GALLEY
Violation: A SANITIZING BUCKET ON A LOWER COUNTER SHELF HAD A FREE CHLORINE RESIDUAL BELOW 50 PPM WHEN TESTED. TWO WIPING CLOTHS WERE NOTED IN THE SOLUTION. THE BUCKET WAS IMMEDIATELY REMOVED AND THE SOLUTION DRAINED.
Recommendation: Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 26
Site: Galley-WINDJAMMER HOT GALLEY
Violation: A FEW PREVIOUSLY CLEANED EATING UTENSILS WERE FOUND SLIGHTLY SOILED WITH FOOD RESIDUE IN THE CLEAN STORAGE RACK BIN.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Galley-CREW GALLEY - POTWASH
Violation: TWO PREVIOUSLY CLEANED LADLES WERE FOUND SOILED AND STORED AS CLEAN.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Galley-MAIN GALLEY - DK 4 - WINE CELLAR
Violation: THREE PREVIOUSLY CLEANED BAR GLASSES WERE FOUND SOILED AND STORED AS CLEAN.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 26
Site: Galley-MAIN GALLEY - DK 5 - WINE CELLAR
Violation: ONE PREVIOUSLY CLEANED BAR GLASS WAS FOUND SOILED AND STORED AS CLEAN.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 28
Site: Galley-MAIN GALLEY - DK 4 - HOT GALLEY
Violation: SEVERAL PREVIOUSLY CLEANED BOWLS WERE FOUND STORED WET IN THE UNDERCOUNTER STORAGE AREA OF THE STEAM TABLE. IT COULD NOT BE DETERMINED IF THE WATER WAS THE RESULT OF CONDENSATE, A POTABLE WATER LEAK OR RESIDUAL WATER FROM DISHWASH OPERATIONS. ALL OF THE DISHES IN THIS AREA WERE REMOVED AND REWASHED DURING THE INSPECTION.
Recommendation: Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 33
Site: Food Service General-FOOD SERVICE GENERAL
Violation: RECESSED OR MISSING GROUT WAS NOTED IN SEVERAL AREAS OF THE FOOD SERVICE OPERATION.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 34
Site: Galley-MAIN GALLEY - DK 4 - SOUP STATION
Violation: A POTABLE WATER LEAK WAS NOTED IN THE DRAIN LINE BENEATH THE SINGLE COMPARTMENT SINK. WATER WAS BEING REDIRECTED FROM THE DRAIN.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 41
Site: Ventilation-AIR SYSTEMS - AIR CONDITIONING FAN UNITS
Violation: AN INSPECTION OF FAN UNIT ACR406-LAT1 AT DECK 7, FIRE ZONE 4 REVEALED THAT ONLY THE ENTRY OF THE CONDENSATE DRAIN PAN (5 INCHES) COULD BE VIEWED FROM THE SMALL ACCESS HATCH IN THE LOWER PANEL OF THE UNIT. THE PAN SECTION HAD A VISIBLE BIOFILM LAYER OF MOLD DEBRIS ATTACHED, AND BETWEEN THE WATER DROPLET PANEL AND THE FAN COIL WAS A SMALL SECTION OF HEAVY DIRT DEBRIS NOTED. THE ACCESS TO INSPECT OR MAINTAIN THE CONDENSATE DRAIN PAN IS VERY POOR DUE TO THE OTHER FAN UNIT OPPOSITE, AND THE WATER DROPLET ELIMINATOR PANEL INSTALLED OVER THE PAN. LARGE DIAMETER PIPES INSERT INTO THE PANEL FROM THE OUTSIDE, FURTHER LIMITING ACCESS. ONLY THE DECK 7 FIRE ZONE 5 FAN UNIT AC502, SERVING THE SOLARIUM GALLEY ON DECK 9 HAD AN INSPECTION HATCH WHERE THE ENTIRE CONDENSATE COLLECTION PAN COULD BE VIEWED.
Recommendation: Ensure that air handling unit condensate drain pans and collection systems are accessible for inspection, maintenance, and cleaning.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program