-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Determination of Particulate Filter Efficiency Level for R100 Series Filters Against Liquid Particulates for Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"Title
"Determination of Particulate Filter Efficiency Level for R100 Series Filters Against Liquid Particulates for Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"
This procedure establishes the procedure for ensuring that the level of protection provided by the particulate filter efficiency level test for R100 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or supplied-air respirators.
DescriptionThis procedure establishes the procedure for ensuring that the level of protection provided by the particulate filter efficiency level test for R100 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or supplied-air respirators.
- Status: Current
- Standard Type(s): Test Method
- Hazard Type(s): Inhalation
- PPE Type(s): Respirators, General
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Determination of Particulate Filter Efficiency Level for R99 Series Filters Against Liquid Particulates for Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"Title
"Determination of Particulate Filter Efficiency Level for R99 Series Filters Against Liquid Particulates for Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"
This procedure establishes the means for ensuring that the level of protection provided by the particulate filter efficiency level test for R99 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying-air respirators.
DescriptionThis procedure establishes the means for ensuring that the level of protection provided by the particulate filter efficiency level test for R99 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying-air respirators.
- Status: Current
- Standard Type(s): Test Method
- Hazard Type(s): Inhalation
- PPE Type(s): Respirators, General
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Determination of Particulate Filter Efficiency Level for R95 Series Filters Against Liquid Particulates: Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"Title
"Determination of Particulate Filter Efficiency Level for R95 Series Filters Against Liquid Particulates: Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"
This procedure establishes the means for ensuring that the level of protection provided by the particulate filter efficiency level test for R95 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying-air respirators.
DescriptionThis procedure establishes the means for ensuring that the level of protection provided by the particulate filter efficiency level test for R95 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying-air respirators.
- Status: Current
- Standard Type(s): Test Method
- Hazard Type(s): Inhalation
- PPE Type(s): Respirators, General
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Determination of Particulate Filter Efficiency Level for N100 Series Filters Against Solid Particulates: Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"Title
"Determination of Particulate Filter Efficiency Level for N100 Series Filters Against Solid Particulates: Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"
This procedure establishes the means for ensuring that the level of protection determined by the particulate filter efficiency level test for N100 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or supplied-air respirators.
DescriptionThis procedure establishes the means for ensuring that the level of protection determined by the particulate filter efficiency level test for N100 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or supplied-air respirators.
- Status: Current
- Standard Type(s): Test Method
- Hazard Type(s): Inhalation
- PPE Type(s): Respirators, General
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Determination of Particulate Filter Efficiency Level for N99 Series Filters Against Solid Particulates for Non-Powered, Air-Purifying Respirators Standard Test Procedure (STP)"Title
"Determination of Particulate Filter Efficiency Level for N99 Series Filters Against Solid Particulates for Non-Powered, Air-Purifying Respirators Standard Test Procedure (STP)"
This procedure establishes the means for ensuring that the particulate filtering efficiency of N99 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meets the minimum certification standards set forth in 42 CFR,Part 84, Subpart K, §84.181. These filters or filter cartridges may be integral to respirator construction; mounted individually, or in sets of up to three; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying respirators. This STP describes the Determination of Particulate Filter Efficiency Level for N99 Series Filters Against Solid Particulates For Non-Powered, Air-Purifying Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can conduct the test and determine whether or not the product passes the test.
DescriptionThis procedure establishes the means for ensuring that the particulate filtering efficiency of N99 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meets the minimum certification standards set forth in 42 CFR,Part 84, Subpart K, §84.181. These filters or filter cartridges may be integral to respirator construction; mounted individually, or in sets of up to three; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying respirators. This STP describes the Determination of Particulate Filter Efficiency Level for N99 Series Filters Against Solid Particulates For Non-Powered, Air-Purifying Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can conduct the test and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s): Test Method
- Hazard Type(s): Inhalation
- PPE Type(s): Non-Powered Air-Purifying Particulate Respirators
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Determination of Particulate Filter Efficiency Level for N95 Series Filters Against Solid Particulates for Non-Powered, Air-Purifying Respirators Standard Test Procedure (STP)"Title
"Determination of Particulate Filter Efficiency Level for N95 Series Filters Against Solid Particulates for Non-Powered, Air-Purifying Respirators Standard Test Procedure (STP)"
This procedure establishes the means for ensuring that the particulate filtering efficiency ofN95 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meets the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, §84.181. These filters or filter cartridges may be integral to respirator construction; mounted individually, or in sets of up to three; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying respirators.
DescriptionThis procedure establishes the means for ensuring that the particulate filtering efficiency ofN95 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meets the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, §84.181. These filters or filter cartridges may be integral to respirator construction; mounted individually, or in sets of up to three; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying respirators.
- Status: Current
- Standard Type(s): Test Method
- Hazard Type(s): Inhalation
- PPE Type(s): Non-Powered Air-Purifying Particulate Respirators
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Determination of Flammability and Heat Resistance, CBRN Air-Purifying Escape Respirators, Standard Testing Procedure (STP)"Title
"Determination of Flammability and Heat Resistance, CBRN Air-Purifying Escape Respirators, Standard Testing Procedure (STP)"
This test establishes the procedure for ensuring that the level of protection provided by the Determination of CBRN Flammability and Heat Resistance, Escape Respirators Standard Testing Procedure submitted for Approval, Extension of Approval, or examined during Certified Product Audits meet the certification requirements set forth in 42 CFR Part 84, Subpart G, Section 84.63 (a)(c)(d); Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Air-Purifying Escape Respirator Dated September 30, 2003 or Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Self-Contained Escape Respirator Dated September 30, 2003.
DescriptionThis test establishes the procedure for ensuring that the level of protection provided by the Determination of CBRN Flammability and Heat Resistance, Escape Respirators Standard Testing Procedure submitted for Approval, Extension of Approval, or examined during Certified Product Audits meet the certification requirements set forth in 42 CFR Part 84, Subpart G, Section 84.63 (a)(c)(d); Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Air-Purifying Escape Respirator Dated September 30, 2003 or Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Self-Contained Escape Respirator Dated September 30, 2003.
- Status: Current
- Standard Type(s): Test Method
- Hazard Type(s): Inhalation
- PPE Type(s): Respirators, General
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of CBRN Organic Vapor (Cyclohexane) Service-Life Test, Loose-Fitting Powered Air-Purifying Respirators (PAPR)"Title
"Standard Test Procedure (STP): Determination of CBRN Organic Vapor (Cyclohexane) Service-Life Test, Loose-Fitting Powered Air-Purifying Respirators (PAPR)"
This test establishes the procedure for ensuring that the level of protection provided by the CBRN Organic Vapor (Cyclohexane) Service Life Test, Loose-Fitting Powered Air-Purifying Respirators (PAPR) Standard Test Procedure submitted for Approval, Extension of Approval, or examined during Certified Product Audits meet the certification requirements set forth in 42 CFR Part 84, Subpart G, Section 84.63(a)(c)(d); Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Powered Air-Purifying Respirator (PAPR). This STP describes the Determination Of CBRN Organic Vapor (Cyclohexane) Service Life Test, Loose-Fitting Powered Air-Purifying Respirators(PAPR) Standard Test Procedure in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test and determine whether the product passes the test.DescriptionThis test establishes the procedure for ensuring that the level of protection provided by the CBRN Organic Vapor (Cyclohexane) Service Life Test, Loose-Fitting Powered Air-Purifying Respirators (PAPR) Standard Test Procedure submitted for Approval, Extension of Approval, or examined during Certified Product Audits meet the certification requirements set forth in 42 CFR Part 84, Subpart G, Section 84.63(a)(c)(d); Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Powered Air-Purifying Respirator (PAPR). This STP describes the Determination Of CBRN Organic Vapor (Cyclohexane) Service Life Test, Loose-Fitting Powered Air-Purifying Respirators(PAPR) Standard Test Procedure in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test and determine whether the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of CBRN Acid Gases (Cyanogen Chloride) Service-Life Test, Loose-Fitting Powered Air-Purifying Respirators (PAPR)"Title
"Standard Test Procedure (STP): Determination of CBRN Acid Gases (Cyanogen Chloride) Service-Life Test, Loose-Fitting Powered Air-Purifying Respirators (PAPR)"
This test establishes the procedure for ensuring that the level of protection provided by the CBRN Acid Gases (Cyanogen Chloride) Service Life Test, Loose-Fitting Powered Air-Purifying Respirators Standard Test Procedure submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR Part 84, Subpart G, 84.63(a)(c)(d); Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Powered Air-Purifying Respirator (PAPR). This STP describes Determination of CBRN Acid Gases (Cyanogen Chloride) Service Life Test, Loose-Fitting Powered Air-Purifying Respirators Standard Testing Procedure in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test and determine whether the product passes the test.DescriptionThis test establishes the procedure for ensuring that the level of protection provided by the CBRN Acid Gases (Cyanogen Chloride) Service Life Test, Loose-Fitting Powered Air-Purifying Respirators Standard Test Procedure submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR Part 84, Subpart G, 84.63(a)(c)(d); Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Powered Air-Purifying Respirator (PAPR). This STP describes Determination of CBRN Acid Gases (Cyanogen Chloride) Service Life Test, Loose-Fitting Powered Air-Purifying Respirators Standard Testing Procedure in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test and determine whether the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of CBRN Acid Gases (Hydrogen Cyanide) Service-Life Test, Loose-Fitting Powered Air-Purifying Respirators (PAPR)"Title
"Standard Test Procedure (STP): Determination of CBRN Acid Gases (Hydrogen Cyanide) Service-Life Test, Loose-Fitting Powered Air-Purifying Respirators (PAPR)"
This test establishes the procedure for ensuring that the level of protection provided by the CBRN Acid Gases (Hydrogen Cyanide) Service Life Test, Loose-fitting Powered Air-Purifying Respirators (PAPR) Standard Test Procedure submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR Part 84, Subpart G, 84.63(a)(c)(d); Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Powered Air-Purifying Respirator (PAPR). This STP describes the Determination of CBRN Acid Gases (Hydrogen Cyanide) Service Life Test, Loose-fitting Powered Air-Purifying Respirators (PAPR) Standard Test Procedure test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedure for ensuring that the level of protection provided by the CBRN Acid Gases (Hydrogen Cyanide) Service Life Test, Loose-fitting Powered Air-Purifying Respirators (PAPR) Standard Test Procedure submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR Part 84, Subpart G, 84.63(a)(c)(d); Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Powered Air-Purifying Respirator (PAPR). This STP describes the Determination of CBRN Acid Gases (Hydrogen Cyanide) Service Life Test, Loose-fitting Powered Air-Purifying Respirators (PAPR) Standard Test Procedure test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
PPE-Info Feedback
Please provide us with feedback so that we may improve PPE-Info in order to better serve you and the general public.
Required FieldPPE-Info Standard Feedback
This feedback is directed towards NIOSH/NPPTL database managers and will not be transferred to standard development organization (SDO) contacts. If you have questions regarding the specific details of a standard, please contact the SDO directly.
Required FieldSearch By
You may chose how to search for standards by selecting an option from the Search By list.
- Title: The search engine will match your search term against the title of a standard.
- Standard Number: The search engine will match your search term against the standard number (eg ANSI 1000) of a standard.
- Full Text: The search engine will match your search term against all fields in the database.
Filters (Advanced Search Only)
By default no options are selected for each filter. This means that all possible values for each filter type will be included in the search. You may add options under each filter to narrow the search results. If you hold the 'CTRL' key while selecting options the list will not close.
- Personal Protective Equipment Category: A category that a piece of PPE falls into, such as Head Protection.
- Hazard Category: A category of hazard that a piece of PPE protects against, such as Chemical.
- Standard Organization: The name of the standard developing organization.
- Standard Type: The type of standard, such as Test Method.
- Standard Status: The current status of a standard.
- SOC Code: A standard occupational classification major code that a piece of PPE deals with.
Full Text Search
Full Text Search will search for each term separated by white space. If you wish to search for a phrase you will need to surround the terms with quotation marks.
- Fall Arrest: Will search for the word Fall and the word Arrest separately
- "Fall Arrest": Will search for the phrase Fall Arrest
- Page last reviewed: February 21, 2024
- Page last updated: February 21, 2024
- Content source: