Skip directly to search Skip directly to A to Z list Skip directly to navigation Skip directly to page options Skip directly to site content
  • This form will generate a query of applicable standards and regulations related to various types of PPE. Leaving the search box empty will return all possible results.
  • The query fields are joined by "AND", meaning that choosing more options will narrow the search. Not choosing any filter values will return all possible results.
  • To search for phrases, enclose search terms in quotation marks.
  • For more detailed information click the question mark button.
Search By
Search
Clear Form
997 Results Found | Page 95 of 100
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Sulfur Dioxide Service-Life Test, Tight-Fitting Powered Air-Purifying Respirators with Gas Mask Canisters"
    Title

    "Standard Test Procedure (STP): Determination of Sulfur Dioxide Service-Life Test, Tight-Fitting Powered Air-Purifying Respirators with Gas Mask Canisters"

    This test establishes the procedure for ensuring that the level of protection provided by tight fitting powered air-purifying respirators (PAPR) with gas mask canister(s) submitted for Approval, Extension of Approval, or examined during Certified Product Audits meet the minimum sulfur dioxide service life test requirements set forth in 42 CFR Part 84, Subpart G, Section 84.63(a)(c)(d) and Subpart I, Section 84.126. This STP describes the Determination of Sulfur dioxide Service Life Test, tight fitting powered air-purifying respirators (PAPR) with gas mask canister(s) test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedure for ensuring that the level of protection provided by tight fitting powered air-purifying respirators (PAPR) with gas mask canister(s) submitted for Approval, Extension of Approval, or examined during Certified Product Audits meet the minimum sulfur dioxide service life test requirements set forth in 42 CFR Part 84, Subpart G, Section 84.63(a)(c)(d) and Subpart I, Section 84.126. This STP describes the Determination of Sulfur dioxide Service Life Test, tight fitting powered air-purifying respirators (PAPR) with gas mask canister(s) test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Particulate Filter Efficiency Level for P100 Series Filters Against Liquid Particulates for Non-Powered Air-Purifying Respirators"
    Title

    "Standard Test Procedure (STP): Determination of Particulate Filter Efficiency Level for P100 Series Filters Against Liquid Particulates for Non-Powered Air-Purifying Respirators"

    This test establishes the procedure for ensuring that the level of protection provided by the particulate filter efficiency level test for P100 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying respirators.This STP describes the Determination of Particulate Filter Efficiency Level for P100 Series Filters Against Liquid Particulates For Non-Powered, Air-Purifying Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can conduct the test and determine whether or not the product passes the test.

    Description

    This test establishes the procedure for ensuring that the level of protection provided by the particulate filter efficiency level test for P100 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying respirators.This STP describes the Determination of Particulate Filter Efficiency Level for P100 Series Filters Against Liquid Particulates For Non-Powered, Air-Purifying Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can conduct the test and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Respirators, General
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of Particulate Filter Efficiency Level for P99 Series Filters Against Liquid Particulates for Non-Powered, Air-Purifying Respirators Standard Test Procedures (STP)"
    Title

    "Determination of Particulate Filter Efficiency Level for P99 Series Filters Against Liquid Particulates for Non-Powered, Air-Purifying Respirators Standard Test Procedures (STP)"

    This procedure establishes the means for ensuring that the particulate filtering efficiency of P99 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meets the minimum certification standards set for in 42 CFR, Part 84, Subpart K, Section 84.181. These filters or filter cartridges may be integral to respirator construction; mounted individually, or in sets of up to three; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying respirators.

    Description

    This procedure establishes the means for ensuring that the particulate filtering efficiency of P99 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meets the minimum certification standards set for in 42 CFR, Part 84, Subpart K, Section 84.181. These filters or filter cartridges may be integral to respirator construction; mounted individually, or in sets of up to three; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying respirators.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Respirators, General
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of Particulate Filter Efficiency Level for P95 Series Filters Against Liquid Particulates for Non-Powered, Air-Purifying Respirators Standard Test Procedure (STP)"
    Title

    "Determination of Particulate Filter Efficiency Level for P95 Series Filters Against Liquid Particulates for Non-Powered, Air-Purifying Respirators Standard Test Procedure (STP)"

    This procedure establishes the means for ensuring that the particulate filtering efficiency of P95 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meets the minimum certification standards set for in 42 CFR, Part 84, Subpart K, §84.181. These filters or filter cartridges maybe integral to respirator construction; mounted individually, or in sets of up to three; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying respirators.

    This STP describes the Determination of Particulate Filter Efficiency Level for P95 Series Filters Against Liquid Particulates For Non-Powered, Air-Purifying Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can conduct the test and determine whether or not the product passes the test.

    Description

    This procedure establishes the means for ensuring that the particulate filtering efficiency of P95 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meets the minimum certification standards set for in 42 CFR, Part 84, Subpart K, §84.181. These filters or filter cartridges maybe integral to respirator construction; mounted individually, or in sets of up to three; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying respirators.

    This STP describes the Determination of Particulate Filter Efficiency Level for P95 Series Filters Against Liquid Particulates For Non-Powered, Air-Purifying Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can conduct the test and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Non-Powered Air-Purifying Particulate Respirators
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of Particulate Filter Efficiency Level for R100 Series Filters Against Liquid Particulates for Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"
    Title

    "Determination of Particulate Filter Efficiency Level for R100 Series Filters Against Liquid Particulates for Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"

    This procedure establishes the procedure for ensuring that the level of protection provided by the particulate filter efficiency level test for R100 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or supplied-air respirators.

    Description

    This procedure establishes the procedure for ensuring that the level of protection provided by the particulate filter efficiency level test for R100 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or supplied-air respirators.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Respirators, General
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of Particulate Filter Efficiency Level for R99 Series Filters Against Liquid Particulates for Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"
    Title

    "Determination of Particulate Filter Efficiency Level for R99 Series Filters Against Liquid Particulates for Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"

    This procedure establishes the means for ensuring that the level of protection provided by the particulate filter efficiency level test for R99 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying-air respirators.

    Description

    This procedure establishes the means for ensuring that the level of protection provided by the particulate filter efficiency level test for R99 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying-air respirators.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Respirators, General
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of Particulate Filter Efficiency Level for R95 Series Filters Against Liquid Particulates: Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"
    Title

    "Determination of Particulate Filter Efficiency Level for R95 Series Filters Against Liquid Particulates: Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"

    This procedure establishes the means for ensuring that the level of protection provided by the particulate filter efficiency level test for R95 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying-air respirators.

    Description

    This procedure establishes the means for ensuring that the level of protection provided by the particulate filter efficiency level test for R95 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying-air respirators.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Respirators, General
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of Particulate Filter Efficiency Level for N100 Series Filters Against Solid Particulates: Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"
    Title

    "Determination of Particulate Filter Efficiency Level for N100 Series Filters Against Solid Particulates: Non-Powered Air-Purifying Respirators Standard Test Procedure (STP)"

    This procedure establishes the means for ensuring that the level of protection determined by the particulate filter efficiency level test for N100 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or supplied-air respirators.

    Description

    This procedure establishes the means for ensuring that the level of protection determined by the particulate filter efficiency level test for N100 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.181. These filters and filter cartridges may be integral components; mounted individually; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or supplied-air respirators.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Respirators, General
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of Particulate Filter Efficiency Level for N99 Series Filters Against Solid Particulates for Non-Powered, Air-Purifying Respirators Standard Test Procedure (STP)"
    Title

    "Determination of Particulate Filter Efficiency Level for N99 Series Filters Against Solid Particulates for Non-Powered, Air-Purifying Respirators Standard Test Procedure (STP)"

    This procedure establishes the means for ensuring that the particulate filtering efficiency of N99 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meets the minimum certification standards set forth in 42 CFR,Part 84, Subpart K, §84.181. These filters or filter cartridges may be integral to respirator construction; mounted individually, or in sets of up to three; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying respirators. This STP describes the Determination of Particulate Filter Efficiency Level for N99 Series Filters Against Solid Particulates For Non-Powered, Air-Purifying Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can conduct the test and determine whether or not the product passes the test.

    Description

    This procedure establishes the means for ensuring that the particulate filtering efficiency of N99 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meets the minimum certification standards set forth in 42 CFR,Part 84, Subpart K, §84.181. These filters or filter cartridges may be integral to respirator construction; mounted individually, or in sets of up to three; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying respirators. This STP describes the Determination of Particulate Filter Efficiency Level for N99 Series Filters Against Solid Particulates For Non-Powered, Air-Purifying Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can conduct the test and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Non-Powered Air-Purifying Particulate Respirators
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of Particulate Filter Efficiency Level for N95 Series Filters Against Solid Particulates for Non-Powered, Air-Purifying Respirators Standard Test Procedure (STP)"
    Title

    "Determination of Particulate Filter Efficiency Level for N95 Series Filters Against Solid Particulates for Non-Powered, Air-Purifying Respirators Standard Test Procedure (STP)"

    This procedure establishes the means for ensuring that the particulate filtering efficiency ofN95 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meets the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, §84.181. These filters or filter cartridges may be integral to respirator construction; mounted individually, or in sets of up to three; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying respirators.

    Description

    This procedure establishes the means for ensuring that the particulate filtering efficiency ofN95 series filters used on non-powered respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meets the minimum certification standards set forth in 42 CFR, Part 84, Subpart K, §84.181. These filters or filter cartridges may be integral to respirator construction; mounted individually, or in sets of up to three; used in conjunction with cartridges and canisters for chin-style, front-mounted, and back-mounted gas masks; or used in combination with gas-and-vapor or atmosphere-supplying respirators.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Non-Powered Air-Purifying Particulate Respirators

PPE-Info Feedback

Please provide us with feedback so that we may improve PPE-Info in order to better serve you and the general public.

Required Field
- Contact Email Address is required and must be a valid email address.
- A Message is required in order to provide feedback.

In order to provide feedback you must verify your user status.

PPE-Info Standard Feedback

This feedback is directed towards NIOSH/NPPTL database managers and will not be transferred to standard development organization (SDO) contacts. If you have questions regarding the specific details of a standard, please contact the SDO directly.

Required Field
- Contact Email Address is required and must be a valid email address.
- A Message is required in order to provide feedback.

In order to provide feedback you must verify your user status.

Search By

You may chose how to search for standards by selecting an option from the Search By list.

  • Title: The search engine will match your search term against the title of a standard.
  • Standard Number: The search engine will match your search term against the standard number (eg ANSI 1000) of a standard.
  • Full Text: The search engine will match your search term against all fields in the database.
Filters (Advanced Search Only)

By default no options are selected for each filter. This means that all possible values for each filter type will be included in the search. You may add options under each filter to narrow the search results. If you hold the 'CTRL' key while selecting options the list will not close.

  • Personal Protective Equipment Category: A category that a piece of PPE falls into, such as Head Protection.
  • Hazard Category: A category of hazard that a piece of PPE protects against, such as Chemical.
  • Standard Organization: The name of the standard developing organization.
  • Standard Type: The type of standard, such as Test Method.
  • Standard Status: The current status of a standard.
  • SOC Code: A standard occupational classification major code that a piece of PPE deals with.
Full Text Search

Full Text Search will search for each term separated by white space. If you wish to search for a phrase you will need to surround the terms with quotation marks.

  • Fall Arrest: Will search for the word Fall and the word Arrest separately
  • "Fall Arrest": Will search for the phrase Fall Arrest
TOP

Loading, please wait