  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Facepiece Carbon Dioxide Concentrations - Self-Contained Breathing Apparatus"
    Title

    "Standard Test Procedure (STP): Determination of Facepiece Carbon Dioxide Concentrations - Self-Contained Breathing Apparatus"

    This test establishes the procedures for ensuring that Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards for carbon dioxide concentration as allowed for set for at 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.97(a)(b)(c); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Facepiece Carbon Dioxide Concentration Levels - Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    Description

    This test establishes the procedures for ensuring that Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards for carbon dioxide concentration as allowed for set for at 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.97(a)(b)(c); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Facepiece Carbon Dioxide Concentration Levels - Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Respirators, General
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Man Tests - Self-Contained Breathing Apparatus"
    Title

    "Standard Test Procedure (STP): Man Tests - Self-Contained Breathing Apparatus"

    This test establishes the procedures for ensuring that the level of protection provided by the Man Test requirements on Self-Contained Breathing Apparatus (SCBA) Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.79, 84.97, 84.99, 84.100, and 84.103, Volume 60, Number 110, June 8, 1995. This STP describes the Man Tests, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedures for ensuring that the level of protection provided by the Man Test requirements on Self-Contained Breathing Apparatus (SCBA) Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.79, 84.97, 84.99, 84.100, and 84.103, Volume 60, Number 110, June 8, 1995. This STP describes the Man Tests, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Man Test Number 5 - Closed-Circuit, Self-Contained Breathing Apparatus"
    Title

    "Standard Test Procedure (STP): Man Test Number 5 - Closed-Circuit, Self-Contained Breathing Apparatus"

    This test establishes the procedure for ensuring that the level of protection provided by the Man test 5 requirements on Closed-Circuit, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part, 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.101, Volume 60, Number 110, June 8, 1995. This STP describes the Man Test Number 5 Closed-Circuit, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedure for ensuring that the level of protection provided by the Man test 5 requirements on Closed-Circuit, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part, 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.101, Volume 60, Number 110, June 8, 1995. This STP describes the Man Test Number 5 Closed-Circuit, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Vibration (Ro-Tap Test) For Man Test Number 1 on - Escape, Closed-Circuit, Demand, Self-Contained Breathing Apparatus"
    Title

    "Standard Test Procedure (STP): Determination of Vibration (Ro-Tap Test) For Man Test Number 1 on - Escape, Closed-Circuit, Demand, Self-Contained Breathing Apparatus"

    This test establishes the procedure for ensuring that the level of protection provided by the vibration requirements on Escape, Closed-Circuit, Demand, Self-Contained Breathing Apparatus (ESCBA) submitted for approval, extension of approval or examined during Certified Product audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d) and Subpart H, Sections 84.97, 84.99, and 84.103; Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Vibration (Ro-Tap Test) For Man Test Number 1 on - Escape, Closed-Circuit, Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedure for ensuring that the level of protection provided by the vibration requirements on Escape, Closed-Circuit, Demand, Self-Contained Breathing Apparatus (ESCBA) submitted for approval, extension of approval or examined during Certified Product audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d) and Subpart H, Sections 84.97, 84.99, and 84.103; Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Vibration (Ro-Tap Test) For Man Test Number 1 on - Escape, Closed-Circuit, Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Low-Temperature Operation - Minimum per Manufacture - Closed-Circuit, Self-Contained Breathing Apparatus"
    Title

    "Standard Test Procedure (STP): Determination of Low-Temperature Operation - Minimum per Manufacture - Closed-Circuit, Self-Contained Breathing Apparatus"

    This test establishes the procedures for ensuring that the level of protection provided by the low temperature requirements on Closed-Circuit, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.79(a), 84.97(d), and 84.98; Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Low Temperature Operation - Minimum Per Manufacture, Closed-Circuit, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedures for ensuring that the level of protection provided by the low temperature requirements on Closed-Circuit, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.79(a), 84.97(d), and 84.98; Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Low Temperature Operation - Minimum Per Manufacture, Closed-Circuit, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Continuous Gas Flow on Constant Flow - Closed-Circuit, Self-Contained Breathing Apparatus"
    Title

    "Standard Test Procedure (STP): Determination of Continuous Gas Flow on Constant Flow - Closed-Circuit, Self-Contained Breathing Apparatus"

    This test establishes the procedures for ensuring that the level of protection provided by the gas flow requirements on Constant Flow, Closed-Circuit, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.94(a); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Continuous Gas Flow on Constant Flow, Closed- Circuit, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedures for ensuring that the level of protection provided by the gas flow requirements on Constant Flow, Closed-Circuit, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.94(a); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Continuous Gas Flow on Constant Flow, Closed- Circuit, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of Sound Level Measurements for Remaining Service-Life Indicators - Self-Contained Breathing Apparatus Standard Test Procedure (STP)"
    Title

    "Determination of Sound Level Measurements for Remaining Service-Life Indicators - Self-Contained Breathing Apparatus Standard Test Procedure (STP)"

    This test establishes the procedures for ensuring that the level of protection provided by the Sound Level Measurements for Remaining Service-Life Indicators requirements on Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Sound Level Measurements for Remaining Service-Life Indicators on Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedures for ensuring that the level of protection provided by the Sound Level Measurements for Remaining Service-Life Indicators requirements on Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Sound Level Measurements for Remaining Service-Life Indicators on Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Noise
    • PPE Type(s): Self-Contained Breathing Apparatus
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Diaphragm Over-Pressurization - Open Circuit, Self-Contained Breathing Apparatus with Belt Mounted Regulators and Breathing Tubes"
    Title

    "Standard Test Procedure (STP): Determination of Diaphragm Over-Pressurization - Open Circuit, Self-Contained Breathing Apparatus with Belt Mounted Regulators and Breathing Tubes"

    This test establishes the procedures for ensuring that the level of protection provided by the diaphragm over pressurization requirements on Open-Circuit, Self-Contained Breathing Apparatus (SCBA) with a belt mounted second stage regulator and a flexible breathing tube connected to the facepiece, submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Diaphragm Over Pressurization on Open-Circuit, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedures for ensuring that the level of protection provided by the diaphragm over pressurization requirements on Open-Circuit, Self-Contained Breathing Apparatus (SCBA) with a belt mounted second stage regulator and a flexible breathing tube connected to the facepiece, submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Diaphragm Over Pressurization on Open-Circuit, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Mode Transfer Test of Combination Open-Circuit, Self-Contained Breathing Apparatus and Supplied-Air Respirators (SCBA/SAR)"
    Title

    "Standard Test Procedure (STP): Determination of Mode Transfer Test of Combination Open-Circuit, Self-Contained Breathing Apparatus and Supplied-Air Respirators (SCBA/SAR)"

    This test establishes the procedures for ensuring that the level of protection provided by the mode transfer test requirements on Combination Open-Circuit, Self-Contained Breathing Apparatus and Type C, Supplied-Air Respirators SCBA/SAR submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Mode Transfer Test of Combination Open-Circuit, Self-Contained Breathing Apparatus and Supplied-Air Respirators SCBA/SAR test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedures for ensuring that the level of protection provided by the mode transfer test requirements on Combination Open-Circuit, Self-Contained Breathing Apparatus and Type C, Supplied-Air Respirators SCBA/SAR submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Mode Transfer Test of Combination Open-Circuit, Self-Contained Breathing Apparatus and Supplied-Air Respirators SCBA/SAR test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Remote Gauge Leak-Flow Test for Open-Circuit, Demand And Pressure-Demand, Self-Contained Breathing Apparatus"
    Title

    "Standard Test Procedure (STP): Determination of Remote Gauge Leak-Flow Test for Open-Circuit, Demand And Pressure-Demand, Self-Contained Breathing Apparatus"

    This test establishes the standard procedure for ensuring that the level of protection provided by the remote gauge leak flow test requirements on Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Post-Certification Product Audits meet the certification requirements set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, 84.82(f)(g), Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Remote Gauge Leak-Flow Test for Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the standard procedure for ensuring that the level of protection provided by the remote gauge leak flow test requirements on Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Post-Certification Product Audits meet the certification requirements set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, 84.82(f)(g), Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Remote Gauge Leak-Flow Test for Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):

PPE-Info Feedback

Please provide us with feedback so that we may improve PPE-Info in order to better serve you and the general public.

Required Field
- Contact Email Address is required and must be a valid email address.
- A Message is required in order to provide feedback.

In order to provide feedback you must verify your user status.

PPE-Info Standard Feedback

This feedback is directed towards NIOSH/NPPTL database managers and will not be transferred to standard development organization (SDO) contacts. If you have questions regarding the specific details of a standard, please contact the SDO directly.

Required Field
- Contact Email Address is required and must be a valid email address.
- A Message is required in order to provide feedback.

In order to provide feedback you must verify your user status.

Search By

You may chose how to search for standards by selecting an option from the Search By list.

  • Title: The search engine will match your search term against the title of a standard.
  • Standard Number: The search engine will match your search term against the standard number (eg ANSI 1000) of a standard.
  • Full Text: The search engine will match your search term against all fields in the database.
Filters (Advanced Search Only)

By default no options are selected for each filter. This means that all possible values for each filter type will be included in the search. You may add options under each filter to narrow the search results. If you hold the 'CTRL' key while selecting options the list will not close.

  • Personal Protective Equipment Category: A category that a piece of PPE falls into, such as Head Protection.
  • Hazard Category: A category of hazard that a piece of PPE protects against, such as Chemical.
  • Standard Organization: The name of the standard developing organization.
  • Standard Type: The type of standard, such as Test Method.
  • Standard Status: The current status of a standard.
  • SOC Code: A standard occupational classification major code that a piece of PPE deals with.
Full Text Search

Full Text Search will search for each term separated by white space. If you wish to search for a phrase you will need to surround the terms with quotation marks.

  • Fall Arrest: Will search for the word Fall and the word Arrest separately
  • "Fall Arrest": Will search for the phrase Fall Arrest
TOP

Loading, please wait