­
­
Skip directly to search Skip directly to A to Z list Skip directly to navigation Skip directly to page options Skip directly to site content
  • This form will generate a query of applicable standards and regulations related to various types of PPE. Leaving the search box empty will return all possible results.
  • To search for phrases, enclose search terms in quotation marks.
  • For more detailed information click the question mark button.
Search By
823 Results Found | Page 67 of 83
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of CBRN Powered Air-Purifying Respirator (PAPR) Performance During Dynamic Testing Against the Chemical Agent Vapor Sarin (GB) Chemical Biological, Radiological, and Nuclear (CBRN)"
    Title

    "Standard Test Procedure (STP): Determination of CBRN Powered Air-Purifying Respirator (PAPR) Performance During Dynamic Testing Against the Chemical Agent Vapor Sarin (GB) Chemical Biological, Radiological, and Nuclear (CBRN)"

    The STP describes test procedures in sufficient detail that a team of persons knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test and determine whether or not the product passes the test. This document establishes the procedures for ensuring the level of respiratory protection provided by Chemical, Biological, Radiological, and Nuclear (CBRN) Protection requirements for Powered Air-Purifying Respirator (PAPR) submitted for Approval, Extension of Approval, or examined during Certification Product Audits, meet the minimum certification standards set forth in Title 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d); Federal Register Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Powered Air- Purifying Respirator (PAPR).
    Description

    The STP describes test procedures in sufficient detail that a team of persons knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test and determine whether or not the product passes the test. This document establishes the procedures for ensuring the level of respiratory protection provided by Chemical, Biological, Radiological, and Nuclear (CBRN) Protection requirements for Powered Air-Purifying Respirator (PAPR) submitted for Approval, Extension of Approval, or examined during Certification Product Audits, meet the minimum certification standards set forth in Title 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d); Federal Register Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Powered Air- Purifying Respirator (PAPR).

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Nuclear Particulate, Biological, Radiological, Chemical
    • PPE Type(s): CBRN protective ensembles
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of CBRN, Powered Air-Purifying Respirator (PAPR) Performance During Dynamic Testing Against Chemical Agent Distilled Sulfur Mustard (HD) Vapor and Distilled Sulfur Mustard (HD) Liquid Chemical, Biological, Radiological, and Nuclear (CBRN)"
    Title

    "Standard Test Procedure (STP): Determination of CBRN, Powered Air-Purifying Respirator (PAPR) Performance During Dynamic Testing Against Chemical Agent Distilled Sulfur Mustard (HD) Vapor and Distilled Sulfur Mustard (HD) Liquid Chemical, Biological, Radiological, and Nuclear (CBRN)"

    The STP describes test procedures in sufficient detail that a team of persons knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test and determine whether or not the product passes the test. This document establishes the procedures for ensuring the level of respiratory protection provided by Chemical, Biological, Radiological, and Nuclear (CBRN) Protection requirements for Powered Air-Purifying Respirator (PAPR) submitted for Approval, Extension of Approval, or examined during Certification Product Audits, meet the minimum certification standards set forth in Title 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d); Federal Register Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Powered Air- Purifying Respirator (PAPR).
    Description

    The STP describes test procedures in sufficient detail that a team of persons knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test and determine whether or not the product passes the test. This document establishes the procedures for ensuring the level of respiratory protection provided by Chemical, Biological, Radiological, and Nuclear (CBRN) Protection requirements for Powered Air-Purifying Respirator (PAPR) submitted for Approval, Extension of Approval, or examined during Certification Product Audits, meet the minimum certification standards set forth in Title 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d); Federal Register Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Powered Air- Purifying Respirator (PAPR).

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Air Flow For Powered Air-Purifying Respirators"
    Title

    "Standard Test Procedure (STP): Determination of Air Flow For Powered Air-Purifying Respirators"

    This test establishes the procedure for ensuring that the level of protection provided by the air flow test requirements on powered air-purifying respirator submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart KK, Section 84.1157(a); Volume 60, Number 110, June 8, 1995. This procedure describes the Determination of Air Flow Procedure to Test Powered Air-Purifying Respirators test in sufficient detail that a person in the appropriate technical field can conduct the test and determine whether or not the product passes the test.
    Description

    This test establishes the procedure for ensuring that the level of protection provided by the air flow test requirements on powered air-purifying respirator submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart KK, Section 84.1157(a); Volume 60, Number 110, June 8, 1995. This procedure describes the Determination of Air Flow Procedure to Test Powered Air-Purifying Respirators test in sufficient detail that a person in the appropriate technical field can conduct the test and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Leakage of Drinking Tube and Accessories for Respirator Facepieces"
    Title

    "Standard Test Procedure (STP): Determination of Leakage of Drinking Tube and Accessories for Respirator Facepieces"

    This test establishes the procedure for ensuring that the level of protection provided by the leakage test of drinking tube and accessories test requirements on respirator facepieces submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR 84, Subpart G, Section 84.63(a)(c)(d) Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Leakage of Drinking Tube and Accessories for Respirator Facepieces test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedure for ensuring that the level of protection provided by the leakage test of drinking tube and accessories test requirements on respirator facepieces submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR 84, Subpart G, Section 84.63(a)(c)(d) Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Leakage of Drinking Tube and Accessories for Respirator Facepieces test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Silica Dust Loading Test: Powered Air-Purifying Respirator Filters"
    Title

    "Standard Test Procedure (STP): Determination of Silica Dust Loading Test: Powered Air-Purifying Respirator Filters"

    This test establishes the procedure for ensuring that the level of protection provided by the silica dust test requirements on HEPA (also known as HE) filters designed for powered air-purifying respirators (PAPRs) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR 84, Subpart G, Section 84.63(a)(c)(d) and Subpart KK, Section 84.1152; Volume 60, Number 110, June 8, 1995. These filters may be integral components of the PAPR; mounted individually; or used in conjunction with cartridges and canisters. This STP describes the Determination of Silica Dust Test Procedure for Powered Air-purifying Respirator Filters test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedure for ensuring that the level of protection provided by the silica dust test requirements on HEPA (also known as HE) filters designed for powered air-purifying respirators (PAPRs) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR 84, Subpart G, Section 84.63(a)(c)(d) and Subpart KK, Section 84.1152; Volume 60, Number 110, June 8, 1995. These filters may be integral components of the PAPR; mounted individually; or used in conjunction with cartridges and canisters. This STP describes the Determination of Silica Dust Test Procedure for Powered Air-purifying Respirator Filters test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of Noise Level Test, Powered Air-Purifying Respirator With Hoods or Helmets Standard Test Procedure (STP)"
    Title

    "Determination of Noise Level Test, Powered Air-Purifying Respirator With Hoods or Helmets Standard Test Procedure (STP)"

    This document establishes the procedure for ensuring that operational noise levels of powered air-purifying respirators with hoods or helmets, as submitted for Approval, Extension of Approval, or examined during Certified Product Audits, do not exceed the established maximum certification requirements as provided for by 42 CFR Part 84, Subpart L, Section84.202, and Subpart K, Section 84.177.

    Description

    This document establishes the procedure for ensuring that operational noise levels of powered air-purifying respirators with hoods or helmets, as submitted for Approval, Extension of Approval, or examined during Certified Product Audits, do not exceed the established maximum certification requirements as provided for by 42 CFR Part 84, Subpart L, Section84.202, and Subpart K, Section 84.177.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Noise
    • PPE Type(s): Respirators, General
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Carbon Monoxide Service Life Test"
    Title

    "Standard Test Procedure (STP): Carbon Monoxide Service Life Test"

    This test establishes the standard procedure for ensuring that gas mask respirators submitted for Approval, Extension of Approval, or examined during Approval Product audits meet the certification requirements set forth in 42 CFR 84. Specifically for this test, the service life for gas mask canisters and escape gas masks from atmospheres containing carbon monoxide (CO) meet the minimum requirements as stated in 42 CFR 84.126 respectively. This STP describes the Carbon Monoxide Service Life Test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the standard procedure for ensuring that gas mask respirators submitted for Approval, Extension of Approval, or examined during Approval Product audits meet the certification requirements set forth in 42 CFR 84. Specifically for this test, the service life for gas mask canisters and escape gas masks from atmospheres containing carbon monoxide (CO) meet the minimum requirements as stated in 42 CFR 84.126 respectively. This STP describes the Carbon Monoxide Service Life Test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Chlorine Service Life: Air-Purifying Respirators "
    Title

    "Standard Test Procedure (STP): Determination of Chlorine Service Life: Air-Purifying Respirators "

    This test establishes the procedure for ensuring that the chlorine service life requirements on chemical cartridges and gas masks air-purifying respirators submitted for Approval, Extension of Approval, or examined during Certified Products Audits, meets the requirements set forth in 42 CFR Part 84, Subpart G, Section 84.63(a)(c)(d), Subpart I, Section 84.126, Subpart L, Section 84.207, and Subpart KK, Section 84.1157, Volume 60, number 110, June 8, 1995. This STP describes the Determination of Chlorine Service Life Test, Air-purifying Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with necessary resolution, conduct the tests, and determine whether or not the product passes the test.
    Description

    This test establishes the procedure for ensuring that the chlorine service life requirements on chemical cartridges and gas masks air-purifying respirators submitted for Approval, Extension of Approval, or examined during Certified Products Audits, meets the requirements set forth in 42 CFR Part 84, Subpart G, Section 84.63(a)(c)(d), Subpart I, Section 84.126, Subpart L, Section 84.207, and Subpart KK, Section 84.1157, Volume 60, number 110, June 8, 1995. This STP describes the Determination of Chlorine Service Life Test, Air-purifying Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with necessary resolution, conduct the tests, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Chlorine Dioxide Service Life Test: Air-Purifying Respirators "
    Title

    "Standard Test Procedure (STP): Determination of Chlorine Dioxide Service Life Test: Air-Purifying Respirators "

    This test establishes the procedure for ensuring that the level of protection provided by the chlorine dioxide service life requirements on chemical cartridges and gas masks air-purifying respirators submitted for Approval, Extension of Approval, or examined during Certified Products Audits, meets the requirements set forth in 42 CFR Part 84, Subpart G, 84(a)(c)(d), Subpart I, Section 84.110(c), Subpart I, Section 84.190(b), and Subpart KK, Section 1157, Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Chlorine Dioxide Service Life test, Air-Purifying Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with necessary resolution, conduct the tests, and determine whether or not the product passes the test.
    Description

    This test establishes the procedure for ensuring that the level of protection provided by the chlorine dioxide service life requirements on chemical cartridges and gas masks air-purifying respirators submitted for Approval, Extension of Approval, or examined during Certified Products Audits, meets the requirements set forth in 42 CFR Part 84, Subpart G, 84(a)(c)(d), Subpart I, Section 84.110(c), Subpart I, Section 84.190(b), and Subpart KK, Section 1157, Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Chlorine Dioxide Service Life test, Air-Purifying Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with necessary resolution, conduct the tests, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of (alpha)-Chloroacetophenone (CN) Service Life Test: Air-Purifying Respirators"
    Title

    "Standard Test Procedure (STP): Determination of (alpha)-Chloroacetophenone (CN) Service Life Test: Air-Purifying Respirators"

    This test establishes the procedure for ensuring that the level of protection provided by the (alpha)-Chloroacetophenone (CN) Service Life requirements on gas mask and air-purifying respirators submitted for Approval, Extension of Approval, or examined during Certified Products Audits, meets the minimum requirements set forth in 42 CFR Part 84, Subpart G, Section 63(a)(c)(d), and Subpart I, Section 84.110, Volume 60, Number 110, June 8, 1995. This STP describes the Determination of (alpha)-Chloroacetophenone (CN) Service Life Air-Purifying Respirators Test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with necessary resolution, conduct the tests, and determine whether or not the product passes the test.
    Description

    This test establishes the procedure for ensuring that the level of protection provided by the (alpha)-Chloroacetophenone (CN) Service Life requirements on gas mask and air-purifying respirators submitted for Approval, Extension of Approval, or examined during Certified Products Audits, meets the minimum requirements set forth in 42 CFR Part 84, Subpart G, Section 63(a)(c)(d), and Subpart I, Section 84.110, Volume 60, Number 110, June 8, 1995. This STP describes the Determination of (alpha)-Chloroacetophenone (CN) Service Life Air-Purifying Respirators Test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with necessary resolution, conduct the tests, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
TOP

Loading, please wait