National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of Air-Regulating Valve 100,000 Cycles, Demand and Pressure-Demand, Type C and CE, Supplied-Air Respirators"Title
"Standard Test Procedure (STP): Determination of Air-Regulating Valve 100,000 Cycles, Demand and Pressure-Demand, Type C and CE, Supplied-Air Respirators"
This test establishes the procedures for ensuring that the level of protection provided by the air-regulating valve requirements on Type C and CE, Demand and Pressure-Demand, Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.150, Table 8; Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Air-Regulating Valve - 100,000 Cycles, Demand and Pressure-Demand, Type C and CE, Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the air-regulating valve requirements on Type C and CE, Demand and Pressure-Demand, Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.150, Table 8; Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Air-Regulating Valve - 100,000 Cycles, Demand and Pressure-Demand, Type C and CE, Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of Airflow - Continuous Flow, Type C and CE, Supplied-Air Respirators"Title
"Standard Test Procedure (STP): Determination of Airflow - Continuous Flow, Type C and CE, Supplied-Air Respirators"
This test establishes the procedures for ensuring that the level of protection provided by the air flow requirements on Type C and CE, Continuous Flow Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.150, Table 8; Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Airflow - Continuous Flow, Type C and CE, Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the air flow requirements on Type C and CE, Continuous Flow Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.150, Table 8; Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Airflow - Continuous Flow, Type C and CE, Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Determination of Airflow - Demand and Pressure-Demand, Type C and CE, Supplied-Air Respirators Standard Test Procedure (STP)"Title
"Determination of Airflow - Demand and Pressure-Demand, Type C and CE, Supplied-Air Respirators Standard Test Procedure (STP)"
This test establishes the procedures for ensuring that the level of protection provided by the air flow requirements on Type C and CE, Demand and Pressure-Demand, Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.150, Table 8. This STP describes the Determination of Airflow - Demand and Pressure-Demand, Type C and CE Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the air flow requirements on Type C and CE, Demand and Pressure-Demand, Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.150, Table 8. This STP describes the Determination of Airflow - Demand and Pressure-Demand, Type C and CE Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s): Standard
- Hazard Type(s): Inhalation
- PPE Type(s): Supplied-Air Respirator
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Determination of Inhalation Airflow Resistance - Pressure-Demand, Type C and CE, Supplied-Air Respirators Standard Test Procedure (STP)"Title
"Determination of Inhalation Airflow Resistance - Pressure-Demand, Type C and CE, Supplied-Air Respirators Standard Test Procedure (STP)"
This test establishes the procedures for ensuring that the level of protection provided by the airflow resistance requirements on Type C and CE, Demand and Pressure-Demand, Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.157(a)(b). This STP describes the Determination of Inhalation Airflow Resistance, Pressure-Demand, Type C and CE, Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the airflow resistance requirements on Type C and CE, Demand and Pressure-Demand, Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.157(a)(b). This STP describes the Determination of Inhalation Airflow Resistance, Pressure-Demand, Type C and CE, Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s): Standard
- Hazard Type(s): Inhalation
- PPE Type(s): Supplied-Air Respirator
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Determination of Exhalation Airflow Resistance - Pressure-Demand, Type C and CE, Supplied-Air Respirators Standard Test Procedure (STP)"Title
"Determination of Exhalation Airflow Resistance - Pressure-Demand, Type C and CE, Supplied-Air Respirators Standard Test Procedure (STP)"
This test establishes the procedures for ensuring that the level of protection provided by the exhalation resistance requirements on Type C and CE, Pressure-Demand, Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.157(c). This STP describes the Determination of Exhalation Airflow Resistance, Pressure-Demand, Type C and CE, Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the exhalation resistance requirements on Type C and CE, Pressure-Demand, Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.157(c). This STP describes the Determination of Exhalation Airflow Resistance, Pressure-Demand, Type C and CE, Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s): Standard
- Hazard Type(s): Inhalation
- PPE Type(s): Supplied-Air Respirator
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of Inhalation Airflow Resistance - Demand, Type C and CE, Supplied-Air Respirators"Title
"Standard Test Procedure (STP): Determination of Inhalation Airflow Resistance - Demand, Type C and CE, Supplied-Air Respirators"
This test establishes the procedures for ensuring that the level of protection provided by the airflow resistance requirements on Type C and CE, Demand, Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.156(a); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Inhalation Airflow Resistance, Demand, Type C and CE, Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the airflow resistance requirements on Type C and CE, Demand, Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.156(a); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Inhalation Airflow Resistance, Demand, Type C and CE, Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of Exhalation Airflow Resistance - Demand, Type C and CE, Supplied-Air Respirators"Title
"Standard Test Procedure (STP): Determination of Exhalation Airflow Resistance - Demand, Type C and CE, Supplied-Air Respirators"
This test establishes the procedures for ensuring that the level of protection provided by the exhalation resistance requirements on Type C and CE, Demand, Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.156(b); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Exhalation Airflow Resistance, Demand, Type C and CE, Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the exhalation resistance requirements on Type C and CE, Demand, Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.156(b); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Exhalation Airflow Resistance, Demand, Type C and CE, Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of Gas-Tightness Test - Isoamyl Acetate, (IAA) - Type C, and CE, Supplied-Air Respirators"Title
"Standard Test Procedure (STP): Determination of Gas-Tightness Test - Isoamyl Acetate, (IAA) - Type C, and CE, Supplied-Air Respirators"
This test establishes the procedures for ensuring that the level of protection provided by the man test for gases and vapors requirements on Type C, and CE Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Sections 84.159, 84.162, and 84.163; Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Man Test for Gases and Vapors, Gas Tightness Test - Isoamyl Acetate, Type C, and CE, Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the man test for gases and vapors requirements on Type C, and CE Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Sections 84.159, 84.162, and 84.163; Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Man Test for Gases and Vapors, Gas Tightness Test - Isoamyl Acetate, Type C, and CE, Supplied-Air Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Determination of Air Velocity and Noise Levels - Sound Level, Type C and CE, Supplied-Air Respirators Standard Test Procedure (STP)"Title
"Determination of Air Velocity and Noise Levels - Sound Level, Type C and CE, Supplied-Air Respirators Standard Test Procedure (STP)"
This test establishes the procedures for ensuring that the level of protection provided by the air velocity and noise level requirements for hoods and helmets used on Type C and CE, Supplied-Air Respirators submitted for Approval or Extension of Approval, meets the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.140; Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Air Velocity and Noise Level - Sound Level, Type C and CE, Supplied-Air Respirator test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the air velocity and noise level requirements for hoods and helmets used on Type C and CE, Supplied-Air Respirators submitted for Approval or Extension of Approval, meets the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart J, Section 84.140; Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Air Velocity and Noise Level - Sound Level, Type C and CE, Supplied-Air Respirator test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s): Test Method
- Hazard Type(s): Noise
- PPE Type(s): Supplied-Air Respirator
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of the Level of Protection Provided by Abrasive Blast, Type CE, Supplied-Air Respirators Using a Challenge Aerosol of NaCl (Sodium Chloride) or Corn Oil"Title
"Standard Test Procedure (STP): Determination of the Level of Protection Provided by Abrasive Blast, Type CE, Supplied-Air Respirators Using a Challenge Aerosol of NaCl (Sodium Chloride) or Corn Oil"
This test establishes the procedures for ensuring that the level of protection provided by the abrasive blast requirements on Type CE, Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits using a challenge aerosol of NaCl (Sodium Chloride) or Corn Oil, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Level the of Protection Provided by Abrasive Blast Type CE, Supplied-Air Respirators using a Challenge Aerosol of NaCl (Sodium Chloride) or Corn Oil tests in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the abrasive blast requirements on Type CE, Supplied-Air Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits using a challenge aerosol of NaCl (Sodium Chloride) or Corn Oil, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Level the of Protection Provided by Abrasive Blast Type CE, Supplied-Air Respirators using a Challenge Aerosol of NaCl (Sodium Chloride) or Corn Oil tests in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
- ««(https://wwwn.cdc.gov/PPEInfo/Search?page=1)
- «(https://wwwn.cdc.gov/PPEInfo/Search?page=69)
- …
- 65(https://wwwn.cdc.gov/PPEInfo/Search?page=65)
- 66(https://wwwn.cdc.gov/PPEInfo/Search?page=66)
- 67(https://wwwn.cdc.gov/PPEInfo/Search?page=67)
- 68(https://wwwn.cdc.gov/PPEInfo/Search?page=68)
- 69(https://wwwn.cdc.gov/PPEInfo/Search?page=69)
- 70
- 71(https://wwwn.cdc.gov/PPEInfo/Search?page=71)
- 72(https://wwwn.cdc.gov/PPEInfo/Search?page=72)
- 73(https://wwwn.cdc.gov/PPEInfo/Search?page=73)
- 74(https://wwwn.cdc.gov/PPEInfo/Search?page=74)
- …
- »(https://wwwn.cdc.gov/PPEInfo/Search?page=71)
- »»(https://wwwn.cdc.gov/PPEInfo/Search?page=83)
- Page last reviewed: February 21, 2024
- Page last updated: February 21, 2024
- Content source: