National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of Exhalation Breathing Resistance - Open-Circuit, Pressure-Demand, Self-Contained Breathing Apparatus Using Two Second Stage Regulators"Title
"Standard Test Procedure (STP): Determination of Exhalation Breathing Resistance - Open-Circuit, Pressure-Demand, Self-Contained Breathing Apparatus Using Two Second Stage Regulators"
This test establishes the procedure for ensuring that the level of protection provided by the exhalation breathing resistance requirements on Open-Circuit, Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) using Two Second Stage Regulators submitted for Approval, Extension of Approval, or examined during Approval Product audits meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d) and Subpart H, Section 84.91(a)(c)(d) Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Exhalation Breathing Resistance - Open-Circuit, Pressure-Demand, Self-Contained Breathing Apparatus Using Two Second Stage Regulators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedure for ensuring that the level of protection provided by the exhalation breathing resistance requirements on Open-Circuit, Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) using Two Second Stage Regulators submitted for Approval, Extension of Approval, or examined during Approval Product audits meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d) and Subpart H, Section 84.91(a)(c)(d) Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Exhalation Breathing Resistance - Open-Circuit, Pressure-Demand, Self-Contained Breathing Apparatus Using Two Second Stage Regulators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of Gasoline Permeation Test on Breathing Bags - Closed-Circuit, Self-Contained Breathing Apparatus"Title
"Standard Test Procedure (STP): Determination of Gasoline Permeation Test on Breathing Bags - Closed-Circuit, Self-Contained Breathing Apparatus"
This test establishes the procedures for ensuring that the level of protection provided by the breathing bag requirements on Closed-Circuit, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.85(a)(b)(c), and 84.88(a)(b)(c)(d); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Gasoline Permeation Test on Breathing Bags, Closed-Circuit, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the breathing bag requirements on Closed-Circuit, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.85(a)(b)(c), and 84.88(a)(b)(c)(d); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Gasoline Permeation Test on Breathing Bags, Closed-Circuit, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of Inhalation and Exhalation Breathing Resistance - Closed-Circuit, Demand And Pressure-Demand, Self-Contained Breathing Apparatus"Title
"Standard Test Procedure (STP): Determination of Inhalation and Exhalation Breathing Resistance - Closed-Circuit, Demand And Pressure-Demand, Self-Contained Breathing Apparatus"
This test establishes the procedures for ensuring that the level of protection provided by the inhalation and exhalation breathing resistance requirements on Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.70(a)(1), 84.90(a)(c), and 84.91(e); Volume 60, Number 110, June 8, 1995. his STP describes the Determination of Inhalation and Exhalation Breathing Resistance, Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the inhalation and exhalation breathing resistance requirements on Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.70(a)(1), 84.90(a)(c), and 84.91(e); Volume 60, Number 110, June 8, 1995. his STP describes the Determination of Inhalation and Exhalation Breathing Resistance, Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of Demand Gas Flow - Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus"Title
"Standard Test Procedure (STP): Determination of Demand Gas Flow - Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus"
This test establishes the procedures for ensuring that the level of protection provided by the the gas flow requirements on Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits meet the certification requirements set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.94(c); Volume 60, Number 110, June 8, 1995, and Federal Register, Volume 50, No. 222, November 18, 1985. This STP describes the Determination of Demand Gas Flow - Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the the gas flow requirements on Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits meet the certification requirements set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.94(c); Volume 60, Number 110, June 8, 1995, and Federal Register, Volume 50, No. 222, November 18, 1985. This STP describes the Determination of Demand Gas Flow - Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of Continuous Gas Flow on Constant Flow with Demand Flow - Closed-Circuit, Self-Contained Breathing Apparatus"Title
"Standard Test Procedure (STP): Determination of Continuous Gas Flow on Constant Flow with Demand Flow - Closed-Circuit, Self-Contained Breathing Apparatus"
This test establishes the procedures for ensuring that the level of protection provided by the gas flow requirements on Constant Flow with Demand, Closed-Circuit, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.94(b); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Continuous Gas Flow on Constant Flow with Demand, Closed-Circuit, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the gas flow requirements on Constant Flow with Demand, Closed-Circuit, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.94(b); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Continuous Gas Flow on Constant Flow with Demand, Closed-Circuit, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of Safety Relief Valve Operation - Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus"Title
"Standard Test Procedure (STP): Determination of Safety Relief Valve Operation - Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus"
This test establishes the procedures for ensuring that the level of protection provided by the relief valve requirements on Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.84(i)(1)(2)(3); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Safety Relief Valve Operation - Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the relief valve requirements on Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.84(i)(1)(2)(3); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Safety Relief Valve Operation - Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of Facepiece Carbon Dioxide Concentrations - Self-Contained Breathing Apparatus"Title
"Standard Test Procedure (STP): Determination of Facepiece Carbon Dioxide Concentrations - Self-Contained Breathing Apparatus"
This test establishes the procedures for ensuring that Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards for carbon dioxide concentration as allowed for set for at 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.97(a)(b)(c); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Facepiece Carbon Dioxide Concentration Levels - Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
DescriptionThis test establishes the procedures for ensuring that Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards for carbon dioxide concentration as allowed for set for at 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.97(a)(b)(c); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Facepiece Carbon Dioxide Concentration Levels - Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s): Test Method
- Hazard Type(s): Inhalation
- PPE Type(s): Respirators, General
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Man Tests - Self-Contained Breathing Apparatus"Title
"Standard Test Procedure (STP): Man Tests - Self-Contained Breathing Apparatus"
This test establishes the procedures for ensuring that the level of protection provided by the Man Test requirements on Self-Contained Breathing Apparatus (SCBA) Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.79, 84.97, 84.99, 84.100, and 84.103, Volume 60, Number 110, June 8, 1995. This STP describes the Man Tests, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedures for ensuring that the level of protection provided by the Man Test requirements on Self-Contained Breathing Apparatus (SCBA) Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.79, 84.97, 84.99, 84.100, and 84.103, Volume 60, Number 110, June 8, 1995. This STP describes the Man Tests, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Man Test Number 5 - Closed-Circuit, Self-Contained Breathing Apparatus"Title
"Standard Test Procedure (STP): Man Test Number 5 - Closed-Circuit, Self-Contained Breathing Apparatus"
This test establishes the procedure for ensuring that the level of protection provided by the Man test 5 requirements on Closed-Circuit, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part, 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.101, Volume 60, Number 110, June 8, 1995. This STP describes the Man Test Number 5 Closed-Circuit, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedure for ensuring that the level of protection provided by the Man test 5 requirements on Closed-Circuit, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part, 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.101, Volume 60, Number 110, June 8, 1995. This STP describes the Man Test Number 5 Closed-Circuit, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
-
National Institute for Occupational Safety and Health (NIOSH)National Institute for Occupational Safety and Health (NIOSH)"Standard Test Procedure (STP): Determination of Vibration (Ro-Tap Test) For Man Test Number 1 on - Escape, Closed-Circuit, Demand, Self-Contained Breathing Apparatus"Title
"Standard Test Procedure (STP): Determination of Vibration (Ro-Tap Test) For Man Test Number 1 on - Escape, Closed-Circuit, Demand, Self-Contained Breathing Apparatus"
This test establishes the procedure for ensuring that the level of protection provided by the vibration requirements on Escape, Closed-Circuit, Demand, Self-Contained Breathing Apparatus (ESCBA) submitted for approval, extension of approval or examined during Certified Product audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d) and Subpart H, Sections 84.97, 84.99, and 84.103; Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Vibration (Ro-Tap Test) For Man Test Number 1 on - Escape, Closed-Circuit, Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.DescriptionThis test establishes the procedure for ensuring that the level of protection provided by the vibration requirements on Escape, Closed-Circuit, Demand, Self-Contained Breathing Apparatus (ESCBA) submitted for approval, extension of approval or examined during Certified Product audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d) and Subpart H, Sections 84.97, 84.99, and 84.103; Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Vibration (Ro-Tap Test) For Man Test Number 1 on - Escape, Closed-Circuit, Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
- Status: Current
- Standard Type(s):
- Hazard Type(s):
- PPE Type(s):
- ««(https://wwwn.cdc.gov/PPEInfo/Search?page=1)
- «(https://wwwn.cdc.gov/PPEInfo/Search?page=72)
- …
- 68(https://wwwn.cdc.gov/PPEInfo/Search?page=68)
- 69(https://wwwn.cdc.gov/PPEInfo/Search?page=69)
- 70(https://wwwn.cdc.gov/PPEInfo/Search?page=70)
- 71(https://wwwn.cdc.gov/PPEInfo/Search?page=71)
- 72(https://wwwn.cdc.gov/PPEInfo/Search?page=72)
- 73
- 74(https://wwwn.cdc.gov/PPEInfo/Search?page=74)
- 75(https://wwwn.cdc.gov/PPEInfo/Search?page=75)
- 76(https://wwwn.cdc.gov/PPEInfo/Search?page=76)
- 77(https://wwwn.cdc.gov/PPEInfo/Search?page=77)
- …
- »(https://wwwn.cdc.gov/PPEInfo/Search?page=74)
- »»(https://wwwn.cdc.gov/PPEInfo/Search?page=83)
- Page last reviewed: February 21, 2024
- Page last updated: February 21, 2024
- Content source: