­
­
Skip directly to search Skip directly to A to Z list Skip directly to navigation Skip directly to page options Skip directly to site content
  • This form will generate a query of applicable standards and regulations related to various types of PPE. Leaving the search box empty will return all possible results.
  • To search for phrases, enclose search terms in quotation marks.
  • For more detailed information click the question mark button.
Search By
823 Results Found | Page 72 of 83
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of Exhalation Breathing Resistance - Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus Standard Test Procedure (STP)"
    Title

    "Determination of Exhalation Breathing Resistance - Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus Standard Test Procedure (STP)"

    This test establishes the procedures for ensuring that the level of protection provided by the exhalation breathing resistance requirements on Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Approved Product audits meet the certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), Subpart H, Section 84.91(a)(b)(c)(d). This STP describes the Determination of Exhalation Breathing Resistance - Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    Description

    This test establishes the procedures for ensuring that the level of protection provided by the exhalation breathing resistance requirements on Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Approved Product audits meet the certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), Subpart H, Section 84.91(a)(b)(c)(d). This STP describes the Determination of Exhalation Breathing Resistance - Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Self-Contained Breathing Apparatus
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of Gas Flow Measurements - Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus Standard Test Procedure (STP)"
    Title

    "Determination of Gas Flow Measurements - Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus Standard Test Procedure (STP)"

    This test establishes the procedures for ensuring that the level of protection provided by the gas flow requirements on Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.93. This STP describes the Determination of Gas Flow Measurements - Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    Description

    This test establishes the procedures for ensuring that the level of protection provided by the gas flow requirements on Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.93. This STP describes the Determination of Gas Flow Measurements - Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Self-Contained Breathing Apparatus
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of Remaining Service-Life Indicator - Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus Standard Testing Procedure (STP)"
    Title

    "Determination of Remaining Service-Life Indicator - Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus Standard Testing Procedure (STP)"

    This test establishes the procedures for ensuring that the level of protection provided by the remaining service-life indicator requirements on Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.83(e)(f). This STP describes the Determination of Remaining Service-Life Indicator - Open-Circuit,Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    Description

    This test establishes the procedures for ensuring that the level of protection provided by the remaining service-life indicator requirements on Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.83(e)(f). This STP describes the Determination of Remaining Service-Life Indicator - Open-Circuit,Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Open-Circuit
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Alarm Pressure - Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus"
    Title

    "Standard Test Procedure (STP): Determination of Alarm Pressure - Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus"

    This test establishes the procedures for ensuring that the level of protection provided by the alarm pressure requirements on Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), Subpart H, Section 84.83(e)(f) and 84.96(a)(b); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Alarm Pressure Test - Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedures for ensuring that the level of protection provided by the alarm pressure requirements on Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), Subpart H, Section 84.83(e)(f) and 84.96(a)(b); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Alarm Pressure Test - Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Gas Tightness - Isoamyl Acetate, (IAA) - Self-Contained Breathing Apparatus with Facepieces and Mouthpieces"
    Title

    "Standard Test Procedure (STP): Determination of Gas Tightness - Isoamyl Acetate, (IAA) - Self-Contained Breathing Apparatus with Facepieces and Mouthpieces"

    This test establishes the procedures for ensuring that the level of protection provided by the gas tightness test requirements on Self-Contained Breathing Apparatus (SCBA) with Facepieces and Mouthpieces submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.104(a)(b), Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Gas Tightness Test (Isoamyl Acetate) - Self-Contained Breathing Apparatus with Facepieces and Mouthpieces test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedures for ensuring that the level of protection provided by the gas tightness test requirements on Self-Contained Breathing Apparatus (SCBA) with Facepieces and Mouthpieces submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.104(a)(b), Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Gas Tightness Test (Isoamyl Acetate) - Self-Contained Breathing Apparatus with Facepieces and Mouthpieces test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Gas Tightness - Isoamyl Acetate, (IAA) - Self-Contained Breathing Apparatus with Hoods or Helmets"
    Title

    "Standard Test Procedure (STP): Determination of Gas Tightness - Isoamyl Acetate, (IAA) - Self-Contained Breathing Apparatus with Hoods or Helmets"

    This test establishes the procedures for ensuring that the level of protection provided by the gas tightness test requirements on Self-Contained Breathing Apparatus (SCBA) with Hoods or Helmets Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.104(a)(b), Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Gas Tightness Test (Isoamyl Acetate) - Self-Contained Breathing Apparatus with Hoods or Helmets test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedures for ensuring that the level of protection provided by the gas tightness test requirements on Self-Contained Breathing Apparatus (SCBA) with Hoods or Helmets Respirators submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.104(a)(b), Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Gas Tightness Test (Isoamyl Acetate) - Self-Contained Breathing Apparatus with Hoods or Helmets test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of By-Pass Valve Flow - Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus"
    Title

    "Standard Test Procedure (STP): Determination of By-Pass Valve Flow - Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus"

    This test establishes the procedures used for ensuring that the level of protection provided by the by-pass valve flow requirements on Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for approval, extension of approval, or examined during Certified Product Audits, meet the minimum certification standards as provided for in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d) Volume 60, Number 110, June 8, 1995. This STP describes the Determination of By-Pass Valve Flow Test - Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    Description

    This test establishes the procedures used for ensuring that the level of protection provided by the by-pass valve flow requirements on Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus (SCBA) submitted for approval, extension of approval, or examined during Certified Product Audits, meet the minimum certification standards as provided for in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d) Volume 60, Number 110, June 8, 1995. This STP describes the Determination of By-Pass Valve Flow Test - Open-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Respirators, General
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of By-Pass Valve Flow - Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus"
    Title

    "Standard Test Procedure (STP): Determination of By-Pass Valve Flow - Closed-Circuit, Demand and Pressure-Demand, Self-Contained Breathing Apparatus"

    This test establishes the procedures for ensuring that the level of protection provided by the by-pass valve flow requirements on Closed-Circuit, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d); Volume 60, Number 110, June 8, 1995. This STP describes the By-Pass Valve Flow Test for Closed-Circuit SCBA test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedures for ensuring that the level of protection provided by the by-pass valve flow requirements on Closed-Circuit, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d); Volume 60, Number 110, June 8, 1995. This STP describes the By-Pass Valve Flow Test for Closed-Circuit SCBA test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Accuracy of Gauge - Self-Contained Breathing Apparatus"
    Title

    "Standard Test Procedure (STP): Determination of Accuracy of Gauge - Self-Contained Breathing Apparatus"

    This test establishes the procedures for ensuring that the level of protection by the accuracy of gauge requirements on Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart H, Section 84.82(a)(b)(c)(d)(h)(i), Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Accuracy of Gauge, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedures for ensuring that the level of protection by the accuracy of gauge requirements on Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart H, Section 84.82(a)(b)(c)(d)(h)(i), Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Accuracy of Gauge, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Inhalation Breathing Resistance - Open-Circuit, Demand, Self-Contained Breathing Apparatus"
    Title

    "Standard Test Procedure (STP): Determination of Inhalation Breathing Resistance - Open-Circuit, Demand, Self-Contained Breathing Apparatus"

    This test establishes the procedures for ensuring that the level of protection provided by the inhalation breathing resistance requirements on Open-Circuit, Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.90(a)(b); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Inhalation Breathing Resistance - Open-Circuit, Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedures for ensuring that the level of protection provided by the inhalation breathing resistance requirements on Open-Circuit, Demand, Self-Contained Breathing Apparatus (SCBA) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart H, Section 84.90(a)(b); Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Inhalation Breathing Resistance - Open-Circuit, Demand, Self-Contained Breathing Apparatus test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
TOP

Loading, please wait