Skip directly to search Skip directly to A to Z list Skip directly to navigation Skip directly to page options Skip directly to site content
  • This form will generate a query of applicable standards and regulations related to various types of PPE. Leaving the search box empty will return all possible results.
  • The query fields are joined by "AND", meaning that choosing more options will narrow the search. Not choosing any filter values will return all possible results.
  • To search for phrases, enclose search terms in quotation marks.
  • For more detailed information click the question mark button.
Search By
Search
Clear Form
997 Results Found | Page 84 of 100
  • National Institute of Justice (NIJ)
    Menu
    Standard Details
    Provide Feedback
    National Institute of Justice (NIJ)
    "Public Safety Bomb Suit Standard"
    Title

    "Public Safety Bomb Suit Standard"

    This document is a voluntary performance standard for bomb suits for use by certified public safety bomb technicians while performing render safe procedures and disposal activities. It defines both performance requirements and the methods used to test performance. In order for a manufacturer, supplier, or other entity to claim that a particular bomb suit model satisfies this standard, the model must be in compliance with this standard, as determined in accordance with this document and the associated document, Public Safety Bomb Suit Certification Program Requirements, NIJ CR-0117.00.

    Description

    This document is a voluntary performance standard for bomb suits for use by certified public safety bomb technicians while performing render safe procedures and disposal activities. It defines both performance requirements and the methods used to test performance. In order for a manufacturer, supplier, or other entity to claim that a particular bomb suit model satisfies this standard, the model must be in compliance with this standard, as determined in accordance with this document and the associated document, Public Safety Bomb Suit Certification Program Requirements, NIJ CR-0117.00.

  • National Institute of Justice (NIJ)
    Menu
    Standard Details
    Provide Feedback
    National Institute of Justice (NIJ)
    "Test Protocol for Comparative Evaluation of Protective Gloves for Law Enforcement and Corrections Applications"
    Title

    "Test Protocol for Comparative Evaluation of Protective Gloves for Law Enforcement and Corrections Applications"

    The purpose of this test protocol is to compare the performance of protective gloves for use by law enforcement, corrections, and military personnel.
    Description

    The purpose of this test protocol is to compare the performance of protective gloves for use by law enforcement, corrections, and military personnel.

  • National Institute of Justice (NIJ)
    Menu
    Standard Details
    Provide Feedback
    National Institute of Justice (NIJ)
    "Hearing protectors for use on firing ranges"
    Title

    "Hearing protectors for use on firing ranges"

    The purpose of this standard is to establish performance requirements and methods of test for wearable devices used to protect the auditory system against the excessive sound encountered on firing ranges.
    Description

    The purpose of this standard is to establish performance requirements and methods of test for wearable devices used to protect the auditory system against the excessive sound encountered on firing ranges.

    • Status: Current
    • Standard Type(s): Specification, Test Method
    • Hazard Type(s): Noise
    • PPE Type(s): Hearing protectors
    • SOC Occupation(s): 33-3051 Officers, Police
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of respirator fit, qualitatively using corn oil aerosol, for powered air-purifying respirators with loose- or tight-fitting respiratory inlet coverings, standard testing procedure"
    Title

    "Determination of respirator fit, qualitatively using corn oil aerosol, for powered air-purifying respirators with loose- or tight-fitting respiratory inlet coverings, standard testing procedure"

    This document establishes the procedure by which a generated corn oil aerosol is used for determining if powered air-purifying respirators (PAPRs) incorporating loose- or tight-fitting respiratory inlet coverings submitted for Approval, Extension of Approval, or examined during Certified Product Audits meet the minimum certification standard set forth in 42 CFR Part 84, Subpart K, Section 84.176.

    Description

    This document establishes the procedure by which a generated corn oil aerosol is used for determining if powered air-purifying respirators (PAPRs) incorporating loose- or tight-fitting respiratory inlet coverings submitted for Approval, Extension of Approval, or examined during Certified Product Audits meet the minimum certification standard set forth in 42 CFR Part 84, Subpart K, Section 84.176.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Inhalation
    • PPE Type(s): Respirators, General
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of CBRN Powered Air-Purifying Respirator (PAPR) Performance During Dynamic Testing Against the Chemical Agent Vapor Sarin (GB) Chemical Biological, Radiological, and Nuclear (CBRN)"
    Title

    "Standard Test Procedure (STP): Determination of CBRN Powered Air-Purifying Respirator (PAPR) Performance During Dynamic Testing Against the Chemical Agent Vapor Sarin (GB) Chemical Biological, Radiological, and Nuclear (CBRN)"

    The STP describes test procedures in sufficient detail that a team of persons knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test and determine whether or not the product passes the test. This document establishes the procedures for ensuring the level of respiratory protection provided by Chemical, Biological, Radiological, and Nuclear (CBRN) Protection requirements for Powered Air-Purifying Respirator (PAPR) submitted for Approval, Extension of Approval, or examined during Certification Product Audits, meet the minimum certification standards set forth in Title 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d); Federal Register Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Powered Air- Purifying Respirator (PAPR).
    Description

    The STP describes test procedures in sufficient detail that a team of persons knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test and determine whether or not the product passes the test. This document establishes the procedures for ensuring the level of respiratory protection provided by Chemical, Biological, Radiological, and Nuclear (CBRN) Protection requirements for Powered Air-Purifying Respirator (PAPR) submitted for Approval, Extension of Approval, or examined during Certification Product Audits, meet the minimum certification standards set forth in Title 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d); Federal Register Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Powered Air- Purifying Respirator (PAPR).

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Biological, Chemical, Nuclear Particulate, Radiological
    • PPE Type(s): CBRN protective ensembles
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of CBRN, Powered Air-Purifying Respirator (PAPR) Performance During Dynamic Testing Against Chemical Agent Distilled Sulfur Mustard (HD) Vapor and Distilled Sulfur Mustard (HD) Liquid Chemical, Biological, Radiological, and Nuclear (CBRN)"
    Title

    "Standard Test Procedure (STP): Determination of CBRN, Powered Air-Purifying Respirator (PAPR) Performance During Dynamic Testing Against Chemical Agent Distilled Sulfur Mustard (HD) Vapor and Distilled Sulfur Mustard (HD) Liquid Chemical, Biological, Radiological, and Nuclear (CBRN)"

    The STP describes test procedures in sufficient detail that a team of persons knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test and determine whether or not the product passes the test. This document establishes the procedures for ensuring the level of respiratory protection provided by Chemical, Biological, Radiological, and Nuclear (CBRN) Protection requirements for Powered Air-Purifying Respirator (PAPR) submitted for Approval, Extension of Approval, or examined during Certification Product Audits, meet the minimum certification standards set forth in Title 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d); Federal Register Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Powered Air- Purifying Respirator (PAPR).
    Description

    The STP describes test procedures in sufficient detail that a team of persons knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test and determine whether or not the product passes the test. This document establishes the procedures for ensuring the level of respiratory protection provided by Chemical, Biological, Radiological, and Nuclear (CBRN) Protection requirements for Powered Air-Purifying Respirator (PAPR) submitted for Approval, Extension of Approval, or examined during Certification Product Audits, meet the minimum certification standards set forth in Title 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d); Federal Register Volume 60, Number 110, June 8, 1995 and the Statement of Standard for Chemical, Biological, Radiological, and Nuclear (CBRN) Powered Air- Purifying Respirator (PAPR).

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Air Flow For Powered Air-Purifying Respirators"
    Title

    "Standard Test Procedure (STP): Determination of Air Flow For Powered Air-Purifying Respirators"

    This test establishes the procedure for ensuring that the level of protection provided by the air flow test requirements on powered air-purifying respirator submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart KK, Section 84.1157(a); Volume 60, Number 110, June 8, 1995. This procedure describes the Determination of Air Flow Procedure to Test Powered Air-Purifying Respirators test in sufficient detail that a person in the appropriate technical field can conduct the test and determine whether or not the product passes the test.
    Description

    This test establishes the procedure for ensuring that the level of protection provided by the air flow test requirements on powered air-purifying respirator submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR, Part 84, Subpart G, Section 84.63(a)(c)(d), and Subpart KK, Section 84.1157(a); Volume 60, Number 110, June 8, 1995. This procedure describes the Determination of Air Flow Procedure to Test Powered Air-Purifying Respirators test in sufficient detail that a person in the appropriate technical field can conduct the test and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Leakage of Drinking Tube and Accessories for Respirator Facepieces"
    Title

    "Standard Test Procedure (STP): Determination of Leakage of Drinking Tube and Accessories for Respirator Facepieces"

    This test establishes the procedure for ensuring that the level of protection provided by the leakage test of drinking tube and accessories test requirements on respirator facepieces submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR 84, Subpart G, Section 84.63(a)(c)(d) Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Leakage of Drinking Tube and Accessories for Respirator Facepieces test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedure for ensuring that the level of protection provided by the leakage test of drinking tube and accessories test requirements on respirator facepieces submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR 84, Subpart G, Section 84.63(a)(c)(d) Volume 60, Number 110, June 8, 1995. This STP describes the Determination of Leakage of Drinking Tube and Accessories for Respirator Facepieces test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Standard Test Procedure (STP): Determination of Silica Dust Loading Test: Powered Air-Purifying Respirator Filters"
    Title

    "Standard Test Procedure (STP): Determination of Silica Dust Loading Test: Powered Air-Purifying Respirator Filters"

    This test establishes the procedure for ensuring that the level of protection provided by the silica dust test requirements on HEPA (also known as HE) filters designed for powered air-purifying respirators (PAPRs) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR 84, Subpart G, Section 84.63(a)(c)(d) and Subpart KK, Section 84.1152; Volume 60, Number 110, June 8, 1995. These filters may be integral components of the PAPR; mounted individually; or used in conjunction with cartridges and canisters. This STP describes the Determination of Silica Dust Test Procedure for Powered Air-purifying Respirator Filters test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.
    Description

    This test establishes the procedure for ensuring that the level of protection provided by the silica dust test requirements on HEPA (also known as HE) filters designed for powered air-purifying respirators (PAPRs) submitted for Approval, Extension of Approval, or examined during Certified Product Audits, meet the minimum certification standards set forth in 42 CFR 84, Subpart G, Section 84.63(a)(c)(d) and Subpart KK, Section 84.1152; Volume 60, Number 110, June 8, 1995. These filters may be integral components of the PAPR; mounted individually; or used in conjunction with cartridges and canisters. This STP describes the Determination of Silica Dust Test Procedure for Powered Air-purifying Respirator Filters test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test, and determine whether or not the product passes the test.

    • Status: Current
    • Standard Type(s):
    • Hazard Type(s):
    • PPE Type(s):
  • National Institute for Occupational Safety and Health (NIOSH)
    Menu
    Standard Details
    Provide Feedback
    National Institute for Occupational Safety and Health (NIOSH)
    "Determination of Noise Level Test, Powered Air-Purifying Respirator With Hoods or Helmets Standard Test Procedure (STP)"
    Title

    "Determination of Noise Level Test, Powered Air-Purifying Respirator With Hoods or Helmets Standard Test Procedure (STP)"

    This document establishes the procedure for ensuring that operational noise levels of powered air-purifying respirators with hoods or helmets, as submitted for Approval, Extension of Approval, or examined during Certified Product Audits, do not exceed the established maximum certification requirements as provided for by 42 CFR Part 84, Subpart L, Section84.202, and Subpart K, Section 84.177.

    Description

    This document establishes the procedure for ensuring that operational noise levels of powered air-purifying respirators with hoods or helmets, as submitted for Approval, Extension of Approval, or examined during Certified Product Audits, do not exceed the established maximum certification requirements as provided for by 42 CFR Part 84, Subpart L, Section84.202, and Subpart K, Section 84.177.

    • Status: Current
    • Standard Type(s): Test Method
    • Hazard Type(s): Noise
    • PPE Type(s): Respirators, General

PPE-Info Feedback

Please provide us with feedback so that we may improve PPE-Info in order to better serve you and the general public.

Required Field
- Contact Email Address is required and must be a valid email address.
- A Message is required in order to provide feedback.

In order to provide feedback you must verify your user status.

PPE-Info Standard Feedback

This feedback is directed towards NIOSH/NPPTL database managers and will not be transferred to standard development organization (SDO) contacts. If you have questions regarding the specific details of a standard, please contact the SDO directly.

Required Field
- Contact Email Address is required and must be a valid email address.
- A Message is required in order to provide feedback.

In order to provide feedback you must verify your user status.

Search By

You may chose how to search for standards by selecting an option from the Search By list.

  • Title: The search engine will match your search term against the title of a standard.
  • Standard Number: The search engine will match your search term against the standard number (eg ANSI 1000) of a standard.
  • Full Text: The search engine will match your search term against all fields in the database.
Filters (Advanced Search Only)

By default no options are selected for each filter. This means that all possible values for each filter type will be included in the search. You may add options under each filter to narrow the search results. If you hold the 'CTRL' key while selecting options the list will not close.

  • Personal Protective Equipment Category: A category that a piece of PPE falls into, such as Head Protection.
  • Hazard Category: A category of hazard that a piece of PPE protects against, such as Chemical.
  • Standard Organization: The name of the standard developing organization.
  • Standard Type: The type of standard, such as Test Method.
  • Standard Status: The current status of a standard.
  • SOC Code: A standard occupational classification major code that a piece of PPE deals with.
Full Text Search

Full Text Search will search for each term separated by white space. If you wish to search for a phrase you will need to surround the terms with quotation marks.

  • Fall Arrest: Will search for the word Fall and the word Arrest separately
  • "Fall Arrest": Will search for the phrase Fall Arrest
TOP

Loading, please wait