"Standard Test method for detection of holes in medical gloves"
This test method covers the detection of holes in medical gloves. This test method is limited to the detection of holes that allow water leakage under the conditions of the test.
A definitive procedure that produces a test result: Examples of test methods include, but are not limited to: identification, measurement, and evaluation of one or more qualities, characteristics, or properties. A precision and bias statement shall be reported at the end of a test method.
All equipment and/or accessories (whether or not detachable) designed and manufactured specifically to protect the arm and/or the hand this includes all garments protecting the hand or part of the hand, including gloves, fingerless gloves, mittens, garments protecting the fingers only or the palm only, etc. Potential hazards include skin absorption of harmful substances, chemical or thermal burns, electrical dangers, bruises, abrasions, cuts, punctures, fractures and amputations.
- Medical gloves
- Biological
-
29-1000 Health Diagnosing and Treating Practitioners
- 29-1062 Practitioners, General
Testing procedures required, please see the full standard for complete details.
No referenced standards.
Bureau Veritas Consumer Products Services Inc. - Buffalo, NY, 14228-1884 |
Contact |
Phone Number: (716) 505-3300 |
Accreditations |
Scope of Accreditation |
ASTM D5151 - 19 , ASTM D5712 - 15(2020) , ASTM D6124 - 06 (Reapproved) , ASTM F1446 - 20 |
Akron Rubber Development Laboratory, Inc. - Akron, OH, 44322-1016 |
Notes |
Accredited Gloves Testing Methods ASTM Testing Methods
The following link points to ARDL's searchable ISO 17025 Scope of Accreditations: https://www.ardl.com/sites/default/files/assets/scope-as-of-8-30-22.pdf |
Contact |
Phone Number: (330) 794-6600 |
Accreditations |
Scope of Accreditation |
ASTM D5151 - 19 , ASTM D5712 - 15(2020) , ASTM D6124 - 06 (Reapproved) , ANSI/AAMI PB70:2022 , ASTM F1342 / F1342M - 05 (Reapproved 2022) , ASTM F1383 - 20 , ASTM F1670 / F1670M - 17a , ASTM F739 - 20 , ASTM F903 - 18 , ANSI/AAMI PB70 - Class 4 , ANSI/AAMI PB70 - Class 3 |
Smithers Rapra - Akron, OH, 44303 |
Contact |
Phone Number: (330) 762-7441 |
Accreditations |
Scope of Accreditation |
Nelson Laboratories, Inc. - Salt Lake City, UT, 84123 |
Notes |
FDA Registered and ANSI-ASQ National Accreditation Board/ACLASS |
Contact |
Phone Number: (801) 290-7500 |
Accreditations |
Scope of Accreditation |
ASTM D5151 - 19 , ASTM D6124 - 06 (Reapproved) , ANSI/AAMI PB70:2022 , ASTM F1342 / F1342M - 05 (Reapproved 2022) , ASTM F1670 / F1670M - 17a , ASTM F1671 / F1671M - 22 , ASTM F1862 / F1862M - 17 , ASTM F2100 - 21 , ASTM F2101 - 22 , ASTM F1819 - 19 , ANSI/AAMI PB70 - Class 4 , ANSI/AAMI PB70 - Class 3 |
Lowenkamp R&D Labs. Ltd. - Hazlehurst, MS, 39083 |
Contact |
Phone Number: (601)-894-2802 |
Scope of Accreditation |
ASTM D5151 - 19 , ASTM D5712 - 15(2020) , ASTM D6124 - 06 (Reapproved) |