"Standard Test Method for Residual Powder on Medical Gloves"

Description

This test method is designed to determine the amount of residual powder and non-powder solids found on medical gloves. This test method is suitable and designed as a reference method to evaluate samples of medical gloves. The mass found using Procedure II, for powdered gloves, is assumed to be a combination of water-insoluble residue remaining after the manufacturing process, former release agents and donning powder.

Standard Type(s)
Test Method

A definitive procedure that produces a test result: Examples of test methods include, but are not limited to: identification, measurement, and evaluation of one or more qualities, characteristics, or properties. A precision and bias statement shall be reported at the end of a test method.

Personal Protective Equipment
Hand and Arm Protection

All equipment and/or accessories (whether or not detachable) designed and manufactured specifically to protect the arm and/or the hand this includes all garments protecting the hand or part of the hand, including gloves, fingerless gloves, mittens, garments protecting the fingers only or the palm only, etc. Potential hazards include skin absorption of harmful substances, chemical or thermal burns, electrical dangers, bruises, abrasions, cuts, punctures, fractures and amputations.

  • Medical gloves
Hazards
Chemical
  • Chemical Reactions
Conformity Assessment Notes

Testing procedures required, please see the full standard for complete details.

Comments

Additional References:

ASTM Standards

  • D4483 Practice for Evaluating Precision for Test Method Standards in the Rubber and Carbon Black Manufacturing Industries

ANSI Standards

  • ANSI/ASQC Z1.9–1993 Sampling Procedures and Tables for Inspection by Variables for Percent Nonconforming
Testing Laboratories
Akron Rubber Development Laboratory, Inc. - Akron, OH, 44322-1016
Notes

Accredited Gloves Testing Methods ASTM Testing Methods

  •  ASTM D6319 - Standard Specification for Nitrile Examination Gloves for Medical Application
  • ASTM D6978 - Standard Practice for Assessment of Resistance of Medical Gloves to Permeation by Chemotherapy Drugs
  • ASTM D7558 - Colorimetric/Spectrophotometric Procedure to Quantify Extractable Chemical Dialkyldithiocarbamate, Thiuram and Mercaptobenzothiazole Accelerators in Natural Rubber Latex and Nitrile Gloves
  • ASTM D120 — Standard Specification for Rubber Insulating Gloves
  • ASTM D3577 — Standard Specification for Rubber Surgical Gloves
  • ASTM D3578 — Standard Specification for Rubber Examination Gloves
  • ASTM D5151 — Standard Test Method for Detection of Holes in Medical Gloves
  • ASTM D6124 — Standard Test Method for Residual Powder on Medical Gloves
  • ASTM D5250 - Standard Specification for Poly (Vinyl Chloride) Gloves for Medical Application
  • ARDL 2140 - Lubricant Compatibility Testing on Gloves
  • ASTM D5712 - Analysis of Aqueous Extractable Protein in Latex, Natural Robber and Elastomeric Products Using the Modified Lowry Method
  • ASTM D6499 - Immunological Measurement of Antigenic Protein in Natural Rubber and Its Products
  • ASTM F739 — Standard Test Method for Permeation of Liquids and Gases Through Protective Clothing Materials Under Conditions of Continuous Contact
  • ASTM F1383 - Permeation of Liquids and Gases Through Protective Clothing Materials Under Conditions of Intermittent Contact
  • ASTM F1670 - Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Synthetic Blood
  • ASTM F1671/F1671M — Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174 Bacteriophage Penetration as a Test System
  • ASTM F903 — Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Liquids
  • ASTM E96/E96M Water Vapor Transmission of Materials
  • ASTM D6977 — Standard Specification for Polychloroprene Examination Gloves for medical Application
  • ASTM D7246 — Standard Test Method for Detection of Holes in Polyethylene Food Service Gloves
  • ASTM D7329 — Standard Specification for Food Preparation and Food Handling Glove

The following link points to ARDL's searchable ISO 17025 Scope of Accreditations: 

https://www.ardl.com/sites/default/files/assets/scope-as-of-8-30-22.pdf

Contact

Phone Number: (330) 794-6600
Email: answers@ardl.com

Accreditations

ISO 17025

Scope of Accreditation

ASTM D120 - 22 , ASTM D3577 - 19(2023) , ASTM D3578 - 19(2023) , ASTM D5151 - 19(2023) , ASTM D5250 - 19(2023) , ASTM D5712 - 15(2020) , ASTM D6124 - 06(2022) , ASTM D6319 - 19(2023) , ASTM D6978 - 05(2023) , ASTM D7246 - 06(2021) , ANSI/AAMI PB70:2022 , ASTM F1342 / F1342M - 05(2022) , ASTM F1383 - 20 , ASTM F1670 / F1670M - 17a , ASTM F1671 / F1671M - 22 , ASTM F739 - 20 , ASTM F903 - 18 , ANSI/AAMI PB70 - Class 4 , ANSI/AAMI PB70 - Class 3

Bureau Veritas Consumer Products Services Inc. - Buffalo, NY, 14228-1884
Contact

Phone Number: (716) 505-3300
Email: joe.margarucci@us.bureauveritas.com

Accreditations

ISO 17025

Scope of Accreditation

ASTM D5151 - 19(2023) , ASTM D5712 - 15(2020) , ASTM D6124 - 06(2022) , ASTM F1446 - 20

Lowenkamp R&D Labs. Ltd. - Hazlehurst, MS, 39083
Contact

Phone Number: (601)-894-2802
Email: lrdltd@aol.com

Scope of Accreditation

ASTM D5151 - 19(2023) , ASTM D5712 - 15(2020) , ASTM D6124 - 06(2022)

Print
TOP

Loading, please wait